• Title/Summary/Keyword: fans

Search Result 711, Processing Time 0.04 seconds

Loss Cut of Air-Cooled Waterwheel Generator with AC Variatle Speed Drive for Cooling Fan Motor(s) (교류 가변속 장치의 냉각팬 적용에 의한 수력 발전기 손실 저감)

  • Hur, Sung-Kwang;Rhew, Hong-Woo;Park, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.579-582
    • /
    • 1989
  • The air-cooled waterwheel generator has a fan connected to waterwheel shaft or motor driven fan or fans. The fans are operated at constant speed, constant input, regardless of generator loss which is varied according to generator output and coolant the perature. Energy savings may he possible if the cooling air flow is controlled according to generato output and air temperature depending on season. The simulation and experience have been done on the 22.6 KVA Waterwheel generator by using AC variable speed drive. The results gave us los cut of generator.

  • PDF

Performance analysis of mixed-flow fans considering the low flow characteristics (저유량 특성을 고려한 사류 송풍기의 성능 해석)

  • Oh, Hyoung Woo;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.110-115
    • /
    • 2000
  • The mean streamline analysis using the empirical loss correlations has been developed for performance prediction of industrial mixed-flow fan impellers in the present study. New simple, but effective, models for the additional Euler input work characteristic and an internal recirculation loss due to internal flow reversal under the low flowrate conditions are proposed in this paper. Comparison of overall performance predictions with six sets of test data of mixed-flow fans is accomplished to demonstrate the accuracy of the proposed models. Predicted performance curves by the present set of loss models agree fairly well with experimental data for a variety of mixed-flow fan impellers over the entire operating conditions. The prediction method presented herein can be used efficiently in the conceptual design phase of mixed-flow fan impellers.

  • PDF

Parametric Design of Axial Fan for Air-Conditioning Unit in terms of Aerodynamic Performance and Noise Level (공조용 축류홴 설계 및 설계변수에 따른 성능과 소음비교)

  • Lee, Seung-Jin;Choi, Go-Bong;Cho, Hong-Jun;Song, Woo-Seog;Lee, Seung-Bae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.3
    • /
    • pp.24-29
    • /
    • 2010
  • Axial fans for an air-conditioning unit are designed to equip the system with an expected flow-rate and low noise level by applying the blade design method of multi-sectioning and local camber generation. In this study, the distributions of chord length, stagger angle, and camber angle are globally and locally determined for the given specific speed, which is considered to be relatively high. The mock-up fans are observed to satisfy the aerodynamic performance and the noise level for the system simultaneously and discussed in terms of local flow patterns related to the emitted noise.

CORRELATION BETWEEN THE OPENING ANGLE OF A LOUVER AND FLOW RATE FOR THE EFFICIENT CONTROL OF A LARGE FAN (대형 팬의 효율적 유량 조절을 위한 루버 개폐각 상관관계)

  • Noh, T.H.;Lee, S.J.;Chang, S.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.272-276
    • /
    • 2007
  • In this paper, we researched a parametric study in flow control system using louver with numerical method. Generally, for the large fans with constant rotational speed, the louver can be used to control the flow rate. The opening and closing of louver can make a some change of flow properties generated by a large fan. To develope the relation between the opening angle of louver and flow rate(or pressure difference), we simulated the flow past the modelled louver installed in a virtual wind tunnel. For the various angles, the mean flow properties are investigated and parameterized with a given boundary condition. The research result can be used directly to design the flow control system of large constant-speed fans, which are often applied to petrolic refinery system.

  • PDF

Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources (다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석)

  • Kim, Jae-Jung;Son, Young-Gap;Chang, Seog-Weon;Ryu, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF

Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 실험적 연구)

  • Choi, Jin-Yong;Cho, Lee-Sang;Cho, Jin-Soo;Won, Eu-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

Automatic 3-D Modeling System for Cooling Fans Based on a Solid Modeler (솔리드 모델러 기반의 냉각탑용 축류팬 자동 설계시스템)

  • 이광일;강재관;김원일;이윤경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.141-144
    • /
    • 1997
  • This paper presents design automation system using API and parametric modeling of solid modeler, which is applied on axial fans for cooling towers. The design data including chord length and twist angle according to the fan length are given by design program, and API functions are applied to automate the modeling and assembly process of fan blade. The boss to connect fan and motor is designed with parametric design function provided by UG so as to be flexibly changed by the value of design parameters. The process of generating 2-D drafting for parts and an assembly is also automated. With developed system, the modeling time is reduced to 5 minutes even with unskilled operators.

  • PDF

Optimal Flow Design of High-Efficiency, Cold-Flow, and Large-size Heat Pump Dryer (히트펌프를 이용한 고효율 냉풍 대형 건조기 유동 최적설계)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2011
  • Drying process, corresponding to a final process in the area of food engineering, requires a lot of heat energy. Thus, the energy efficiency is very important for dryers. Since the energy efficiency of heat pump dryers is much higher compared to that of electric dryers or other types of dryers, most of large-capacity dryers are adopting heat pump. In this study, shapes, positions and number of air-circulating fans, guide vanes, air inlet, outlet and top separator were varied for optimization of the flow of a large-capacity heat pump dryer. In addition, fans were modelled with performance curves and porous media were assumed for foods and heat exchangers. The simulation results were applied to the 12-ton dryer and the velocity distributions were experimentally examined. Finally, uniform drying in time was successfully accomplished through frozen pepper experiment.

Noise Optimization of the Cooling Fan in an Engine Room by using Neural Network (신경망이론을 적용한 엔진룸내의 냉각팬 소음 최적화 연구)

  • Chung, Ki-Hoon;Park, Han-Lim;Kim, Bum-Sub;Kim, Jae-Seung;Lee, Duck-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.318.2-318
    • /
    • 2002
  • Axial fans are widely used in heavy machines due to their ability to produce high flow rate fur cooling of engines. At the same time, the noise generated by these fans causes one of the most serious problems. This work is concerned with the low noise technique of discrete frequency noise. To calculate the unsteady resultant force over the fan blade in an unsymmetric engine room, Time-Marching Free-Wake Method is used. From the calculations of unsteady force on fan blades, noise signal of an engine cooling fan is calculated by using an acoustic similarity law. (omitted)

  • PDF

Noise Radiation Analysis of the Cooling Fan in a Heavy Equipment (중장비 팬의 엔진룸을 통한 소음방사 해석)

  • 정기훈;전완호;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.954-960
    • /
    • 2001
  • Axial fans are widely used in heavy machines due to their ability to produce high cooling of engines. At the same time. the noise generated by these fans causes or serious problems. This work is concerned with the low noise technique of discrete. The prediction model. which allowed the calculation of acoustic pressure at the frequency and it's harmonics, has been developed by Farrasat and the Helmholtz-Kir. The newly developed Helmholtz-Kirchhoff BEM for thin body is used to calculate the sound field of the fan that is located in a engine room. To calculate the unsteady resultant force over blade. Time-Marching Free-Wake Method are used. The fan noise of fan sys unsymmetric engine-room is predicted. In this paper. the discussion is confined to and discrete noise of axial fan and front Part of engine room in heavy equipments.

  • PDF