• Title/Summary/Keyword: fan-beam

Search Result 91, Processing Time 0.038 seconds

Performance Comparison of Reconstruction Algorithms for Fan-Beam Computerized Tomography (Fan-Beam CT 영상 재구성 알고리즘 성능 비교)

  • 이상철;조민형;이수열
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.223-229
    • /
    • 2001
  • In this paper, we have compared the direct fan-beam reconstruction method with the rebinning method in terms of computation time and spatial resolution using computer simulation. As a result, the direct fan-beam method is superior to the rebinning method in the spatial resolution though the former needs longer computation time. However, if we adopt the quarter-detector-offset technique to improve the spatial resolution, the rebinning method outperforms the direct fan-beam method. The computation times have been evaluated using the fast algorithms optimized to reduce the number of interpolation calculations at the back-projection, and the spatial resolutions have been compared using the computer generated phantoms.

  • PDF

Development of Regularized Expectation Maximization Algorithms for Fan-Beam SPECT Data (부채살 SPECT 데이터를 위한 정칙화된 기댓값 최대화 재구성기법 개발)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Soo-Jin;Kim, Kyeong-Min;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.464-472
    • /
    • 2005
  • Purpose: SPECT using a fan-beam collimator improves spatial resolution and sensitivity. For the reconstruction from fan-beam projections, it is necessary to implement direct fan-beam reconstruction methods without transforming the data into the parallel geometry. In this study, various fan-beam reconstruction algorithms were implemented and their performances were compared. Materials and Methods: The projector for fan-beam SPECT was implemented using a ray-tracing method. The direct reconstruction algorithms implemented for fan-beam projection data were FBP (filtered backprojection), EM (expectation maximization), OS-EM (ordered subsets EM) and MAP-EM OSL (maximum a posteriori EM using the one-step late method) with membrane and thin-plate models as priors. For comparison, the fan-beam protection data were also rebinned into the parallel data using various interpolation methods, such as the nearest neighbor, bilinear and bicubic interpolations, and reconstructed using the conventional EM algorithm for parallel data. Noiseless and noisy projection data from the digital Hoffman brain and Shepp/Logan phantoms were reconstructed using the above algorithms. The reconstructed images were compared in terms of a percent error metric. Results: for the fan-beam data with Poisson noise, the MAP-EM OSL algorithm with the thin-plate prior showed the best result in both percent error and stability. Bilinear interpolation was the most effective method for rebinning from the fan-beam to parallel geometry when the accuracy and computation load were considered. Direct fan-beam EM reconstructions were more accurate than the standard EM reconstructions obtained from rebinned parallel data. Conclusion: Direct fan-beam reconstruction algorithms were implemented, which provided significantly improved reconstructions.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Fan-Beam Microstrip Array Antenna for X-B and Radar

  • Park, Jung-Ryul;Kim, Gue-Chol
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.483-486
    • /
    • 2011
  • In this study, a fan-beam microstrip array antenna for an X-band radar was designed and fabricated using a novel technique. A microstrip array structure was used to obtain a high-gain and narrow horizontal beam-width. The feeding point is located at the center of the antenna because of its $360^{\circ}$ rotational characteristic. The measured results indicate a gain of 23dBi, and a horizontal and vertical beamwidth of $3.57^{\circ}$, $26.12^{\circ}$, respectively. The proposed antenna performed adequately and managed to meet the specifications.

Design of the Narrow Beam for Sidescan Sonar (Sidescan Sonar용 Narrow Beam의 설계)

  • 이종무;이종식
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.107-113
    • /
    • 1993
  • Sidescan sonar uses the fan type beam which has horizontally narrow and vertically somewhat wide beam pattern. To construct such a beam we will use an array of transducers. In case of using single transducer it must have a high frequency to have the fan type beam, but in case of using an array it must have to be high frequency. We are planning to use 30 kHz transducers for our sidescan sonar under development. This paper shows ways of designing a narrow beam for the sidescan sonar system by illustrating various shapes of the beam patterns.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Propagation Characteristics of Fan Beam in Subway Tunnel Environment for 2.4 GHz Band Wireless LAN (2.4 GHz 대역 무선 랜을 위한 지하철 터널 환경에서 Fan Beam 의 전파특성)

  • 박노준;고거다;송문규;강영진
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.298-301
    • /
    • 2003
  • 본 논문에서는 2.4 [GHz] 대역에서 1(equation omitted)2 마이크로스트림 배열 안테나를 이용한 지하철 터널내의 전파특성을 고찰하였다. 445 [m]의 터널구간에서 협대역 측정결과 LOS (Line-of-Sight)구간에 비하여 NLOS(Non-Line-of-Sight)구간에서는 수신 전력 레벨이 급격히 감소 하였으며, 10단 길이의 PN Sequence를 이용한 광대역 채널 측정에서는 Fan Beam의 평균과도지연과 RMS 지연확산이 각각 3.5736 [ns]과 11.7327 [ns]로서 원편파와 지향성 빔에 비하여 우수함을 확인하였다. 또한 전체 측정구간에 대한 평균과도지연과 RMS 지연확산의 중간값과 표준편차를 구하였고 각각의 빔에 대하여 비교하였다.

  • PDF

Noise Properties for Filtered Back Projection in CT Reconstruction (필터보정역투영 CT 영상재구성방법에서 잡음 특성)

  • Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.357-364
    • /
    • 2014
  • The filtered back projection in the image reconstruction algorithms for the clinic computed tomography system has been widely used. Noise of the reconstructed image was examined under the input noise for parallel and fan beam geometries. The reconstruction images of $512{\times}512$ size were carried out under 360 and 720 projection by the Visual C++ for parallel beam and fan beam, respectively, and those agreed with the original Shepp-Logan head phantom very much. Noise was generated because of intrinsic restriction (finite number of projections) for the image reconstruction algorithm, filtered back projection, when no input noise was applied. Because the result noise was rapidly increased under 0.5% input noise ratio, technologies for reducing noise in CT system and image processing is important.

Practical theory and ocean survey application of side scan sonar (Side Scan Sonar 실무이론과 현장조사에 적용)

  • Kim, Seong-Ryul;Lee, Yong-Kuk;Jung, Baek-Hun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.201-204
    • /
    • 2006
  • In the side scan sonar method, use is made of the back-scattering, at low grazing angles of incidence to the seabed, of relatively high-frequency acoustic waves radiated in a fan-shaped beam from a transducer contained in a towed body. The fan beam is oriented so that the wider angle is in the vertical plane (scan range) and the narrower angle in the horizontal plane (beam width) with the axis of the beam normal to the ship track. The display of the returns is usually realized as a series of closely spaced intensity-modulated lines on a paper recorder or computer screen display. In this way a two-dimensional picture of the seabed is build up.

  • PDF

High performance metal-only fan-beam reflectarray with a delta source applicable for an electromagnetic fence

  • Cho, Yong-Heui
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.44-49
    • /
    • 2011
  • The scattering solutions for multiple rectangular metallic gratings in a perfectly conducting plane excited by the TE and TM delta sources are presented using an overlapping T-block method. A reflectarray composed of rectangular metallic gratings shows fanbeam radiation patterns that are useful for an electromagnetic fence. The scattering characteristics of multiple rectangular gratings were computed in terms of total radiated power and antenna directivity. The design method of a fan-beam reflectarray to obtain high directivity was also compared with superdirective radiation and parabolic reflector phase.