• Title/Summary/Keyword: fan motor

Search Result 252, Processing Time 0.035 seconds

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF

Optimal design of impeller in fan motor unit of cordless vacuum cleaner for improving flow performance and reducing aerodynamic noise (무선진공청소기 팬 모터 단품의 유량성능 향상과 공력소음 저감을 위한 임펠라 최적설계)

  • Kim, KunWoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.379-389
    • /
    • 2020
  • In this study, the flow and noise performances of high-speed fan motor unit for cordless vacuum cleaner is improved by optimizing the impeller which drives the suction air through flow passage of the cordless vacuum cleaner. Firstly, the unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equations are solved to investigate the flow through the fan motor unit using the computational fluid dynamics techniques. Based on flow field results, the Ffowcs-Williams and Hawkings (FW-H) integral equation is used to predict flow noise radiated from the impeller. Predicted results are compared to the measured ones, which confirms the validity of the numerical method used. It is found that the strong vortex is formed around the mid-chord region of the main blades where the blade curvature change rapidly. Given that vortex acts as a loss for flow and a noise source for noise, impeller blade is redesigned to suppress the identified vortex. The response surface method using two factors is employed to determine the optimum inlet and outlet sweep angles for maximum flow rate and minimum noise. Further analysis of finally selected design confirms the improved flow and noise performance.

Design optimization of the staking line for an electric fan blade using CFD (CFD를 이용한 선풍기 날개의 스태킹 라인 최적 설계)

  • Park, Seunghwan;Ryu, Minhyoung;Cho, Leesang;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.903-910
    • /
    • 2014
  • Electric fans, which consist of axial blades, are operated by the induction motor. In this paper, the objective of this study is the performance improvement of the base model fan using the design optimization. In order to aerodynamic analysis, computational simulations are performed using commercial tool ANSYS-CFX ver. 14.5. And k-${\omega}$ SST turbulence model is used for the CFD analysis. The design variables are set up as sweep and lean angles. Volumetric flow rate and torque of the fan blades are fixed to objective function. The optimized model is shown the increment of the volumetric flow rate and the reduction of the torque compared with the base model. The experimental procedure is followed KS C 9301. CFD results and experimental results are fairly well matched.

A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM (유한요소법을 이용한 냉각홴의 진동 및 간섭에 관한 연구)

  • Seo Jong-Hwi;Song Ha-Jong;Park Tae-Won;Kim Joo-Yong;Jung Il-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.903-909
    • /
    • 2004
  • A CFA(cooling fan assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

Design of small BLDC Fan motor for efficiency improvement (효율 향상을 위한 소형 BLDC 팬 모터 설계)

  • Yun, Seung-Ju;Kim, Hoe-Cheon;Jung, Tea-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.959-960
    • /
    • 2011
  • 본 논문에서는 영구자석 오버행 구조를 가진 소형 BLDC 팬 모터의 효율 향상을 위한 연구를 하였다. 2차원 해석시 오버행에 따른 유효자속량을 고려한 오버행 계수를 산정하여 3차원 해석모델을 2차원 등가화가 가능하게 하여 실험하였다. 그리고 기존의 BLDC 팬 모터에 돌극형 회전자 철심을 삽입하여 영구자석 토크에 릴럭턴스 토크를 추가로 활용함으로써 효율을 향상시키는 연구를 하였다.

  • PDF

Water Caves of Liaoning in Northeastern China -Shenyang Water Cave and Benxi Water Cave-

  • Soh Dea Wha;Fan Zhanguo
    • Journal of the Speleological Society of Korea
    • /
    • no.65
    • /
    • pp.39-51
    • /
    • 2004
  • To introduce the typical water caves of the northeastern district in China, the Shenyang Water Cave located in the Shenyang city and the Benxi Water Cave located in the Benxi city of the Liaoning province of the northeastern part of China are presented. The caves are very big and long, and the water flows in the cave to drive the motor boat for tourist watching the beautiful sight in the caves through the year. The geological information and the beautiful internal sight of views in the caves are introduced.

A study on the development of a new sensorlss drive system for the brushless DC motors (브러시리스 직류 전동기용 새로운 센서리스 드라이브 개발에 관한 연구)

  • 장항제
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.591-595
    • /
    • 2000
  • In this paper we proposed a new sensorless drive system for the trapezoidal type brushless DC motor which does not use any mechanical position or speed sensor and applicable to the systems requiring a constant speed and torque such as Fan. For this a novel indirect rotor position sensing technique based on a detailed analysis of the terminal voltage characteristics is proposed in this paper. And a sensorless drive system for the brushless DC motor is implemented using a 87c196mc fo the main microprocessor and a power FET for the inverter. The experimental results will show the validity of the proposed indirect sensing method and the practical use of the sensorless drive

  • PDF

A Study on Bearing Diagnosis of Induction Motor using Torque Signature (유도 전동기의 토크신호를 이용한 베어링 고장진단 연구)

  • Hong, Young-Hee;Seon, Hyun-Gyu;Park, Jin-Yeub
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.638_639
    • /
    • 2009
  • The motors faults including mechanical rotor imbalances, broken rotor bar, bearing failure and eccentricities problems are reflected in electric, electromagnetic and mechanical quantities. This paper presents a study and the practical implementation of an induction motor for reactor containment fan cooler in nuclear power plant with Electric Signature Analysis(ESA). The results obtained present a good degree of reliability hence; the ESA predictive maintenance tools enable a pro-active evaluation of induction motors performance prior to failure.

  • PDF