• Title/Summary/Keyword: false-negative

Search Result 511, Processing Time 0.023 seconds

Effect of ethylenediamine on luminol (or Bluestar) - bleach reaction (Ethylenediamine이 luminol (or Bluestar) - 표백제 반응에 미치는 영향)

  • Seulgi, Jang;Minkyoung, Kim;Heejin, Kim;Munhee, Lee;Sungwook, Hong
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.242-248
    • /
    • 2022
  • The effect of ethylenediamine (EDA) on the reaction of luminol or Bluestar with blood and bleaches was studied. For this purpose, blood, chlorine bleach, and oxygen bleach were applied to filter paper, treated with EDA-containing luminol or Bluestar, and the changes in chemiluminescence intensity were observed. It was found that the chemiluminescence intensity of the luminol (or Bluestar)-blood reaction did not change with the increasing concentration of EDA. However, the chemiluminescence intensity of the luminol (or Bluestar)-chlorine bleach reaction decreased and the chemiluminescence intensity of the luminol (or Bluestar)-oxygen bleach reaction increased, with increasing EDA concentration. Thus, it was found that when EDA was added to luminol (or Bluestar), which is a blood-sensitive reagent, EDA suppressed the false-positive reaction induced by chlorine bleach and induced a false-positive reaction with oxygen bleach. Consequently, the addition of EDA is not recommended for enhancing bloodstains with luminol or Bluestar.

Pragmatic Strategies of Self (Other) Presentation in Literary Texts: A Computational Approach

  • Khafaga, Ayman Farid
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.2
    • /
    • pp.223-231
    • /
    • 2022
  • The application of computer software into the linguistic analysis of texts proves useful to arrive at concise and authentic results from large data texts. Based on this assumption, this paper employs a Computer-Aided Text Analysis (CATA) and a Critical Discourse Analysis (CDA) to explore the manipulative strategies of positive/negative presentation in Orwell's Animal Farm. More specifically, the paper attempts to explore the extent to which CATA software represented by the three variables of Frequency Distribution Analysis (FDA), Content Analysis (CA), and Key Word in Context (KWIC) incorporate with CDA decipher the manipulative purposes beyond positive presentation of selfness and negative presentation of otherness in the selected corpus. The analysis covers some CDA strategies, including justification, false statistics, and competency, for positive self-presentation; and accusation, criticism, and the use of ambiguous words for negative other-presentation. With the application of CATA, some words will be analyzed by showing their frequency distribution analysis as well as their contextual environment in the selected text to expose the extent to which they are employed as strategies of positive/negative presentation in the text under investigation. Findings show that CATA software contributes significantly to the linguistic analysis of large data texts. The paper recommends the use and application of the different CATA software in the stylistic and corpus linguistics studies.

Usefulness of Direct Cortical Stimulation During Intraoperative Monitoring in Patients with Brain Tumor Near Motor Cortex: Case Report (운동피질영역 주변의 뇌종양 환자에서 수술 중 직접피질자극 검사의 유용성)

  • Lim, Sung-Hyuk;Park, Sang-Ku;Kim, Dong-Jun;Baek, Jae-Seung;Park, Chan-Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.211-215
    • /
    • 2018
  • The aim of this study was to preserve the corticospinal tract during surgery and assess more accurately the motor performance in brain tumor patients around the motor cortex. TceMEP is not entirely reliable, even though there has been no change in waveforms due to a mixture of false positive and false negative signals. For a more detailed examination, DCS was employed to selectively stimulate the motor cortex. In both cases, the indications could find the region to which the cortex was responsible, and constantly check and examine the changes in amplitude, thereby preserving the motor pathway and performing surgery. On the other hand, patients who did not implement the DCS but did implement the TceMEP experienced a decrease in their postoperative motor performance. DCS is a very useful examination and it is a method that can reduce the post-surgery disorder that may occur in patients with the TceMEP in brain tumor surgery.

A Comparative Analysis on The Efficiency of Various Clinical Methods for Diagnosis of Tuberculosis (결핵 진단을 위한 검사 방법간의 효율성에 관한 비교 분석)

  • 최석철;정천환;성희경;김태운;이원재
    • Biomedical Science Letters
    • /
    • v.5 no.2
    • /
    • pp.191-200
    • /
    • 1999
  • In recent years continuously increasing number of tuberculosis (TB) cases due to the emergence of strains with multidrug resistance and AIDS is a significant global health problem. Therefore, more rapid and reliable diagnosis of TB may be one of the most urgent needs in efforts to eradicate the disease. The present study was designed to compare and assess the diagnostic values and efficiencies between the conventional methods (X-ray, AFB stain and culture) and PCR for pulmonary TB on 171 cases. Chest X-ray finding and clinical features revealed that 39 (22.8%) of 171 sputum specimens were pulmonary TB cases. The statistical data were taken on the basis of the definitive diagnosis: In X-ray, overall sensitivity, specificity, efficiency and false positive and false negative incidence was respectively 69.2%, 87.1%, 83.0%, 12.9%, and 30.8%; 79.5%, 95.5%, 91.8%,4.6% and 20.5% in AFB-stain; 56.4%, 99.2%,89.5%, 0.8% and 43.6% in culture; 82.1%, 96.2%, 93.0%, 3.8% and 17.9% in PCR. PCR got a highest sensitivity and efficiency as well as a lowest false negative incidence. Culture had a highest specificity with a lowest false positive incidence. These results imply that PCR assay is fast, sensitive and efficient method for diagnosis of pulmonary TB. However, combined use of the conventional methods with thorough quality control may offer more opportunities for detecting Mycobacterium tuberculosis and diagnosting TB although they have some limits.

  • PDF

Application of Symbolic Representation Method for Fault Detection and Clustering in Semiconductor Fabrication Processes (반도체공정 이상탐지 및 클러스터링을 위한 심볼릭 표현법의 적용)

  • Loh, Woong-Kee;Hong, Sang-Jeen
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.11
    • /
    • pp.806-818
    • /
    • 2009
  • Since the invention of the integrated circuit (IC) in 1950s, semiconductor technology has undergone dramatic development up to these days. A complete semiconductor is manufactured through a diversity of processes. For better semiconductor productivity, fault detection and classification (FDC) has been rigorously studied for finding faults even before the processes are completed. For FDC, various kinds of sensors are attached in many semiconductor manufacturing devices, and sensor values are collected in a periodic manner. The collection of sensor values consists of sequences of real numbers, and hence is regarded as a kind of time-series data. In this paper, we propose an algorithm for detecting and clustering faults in semiconductor processes. The proposed algorithm is a modification of the existing anomaly detection algorithm dealing with symbolically-represented time-series. The contributions of this paper are: (1) showing that a modification of the existing anomaly detection algorithm dealing with general time-series could be used for semiconductor process data and (2) presenting experimental results for improving correctness of fault detection and clustering. As a result of our experiment, the proposed algorithm caused neither false positive nor false negative.

Association between False Positive, False Negative, High-Background Cases and Humidity in One Lambda LABTypeTM HLA-DR Typing (One Lambda LABTypeTM을 이용한 HLA- DR Typing시 나타나는 위양성과 위음성, High-Background 사례와 검사실 습도의 관계분석)

  • Hyang Son AN;Minsung SOHN
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.3
    • /
    • pp.132-142
    • /
    • 2023
  • Human leukocyte antigen (HLA) typing was performed in the diagnostic immunology laboratory of the Seoul National University Hospital. Among 611 HLA-DR tests, specific bead reactions suspected of being false positive and false negative in Lot 20 reagents were found. Therefore, we aimed to identify the factors causing cut-off corrections by examining cases where cut-off corrections were not made for 533 test results and cases where cut-off corrections were made for 78 cases after the cut-off corrections of specific beads. Frequency analysis was conducted to verify the demographic characteristics, and descriptive statistics were used to assess the humidity in the laboratory as a variable. Cross-tabulation was done to examine the association between cut-off corrections and demographic characteristics. Independent samples t-tests were conducted to verify the difference in humidity based on cut-off corrections. Finally, logistic regression analysis was conducted to examine the relationship between humidity levels and the rate of cut-off corrections, and results showed as the humidity level in the laboratory highs, the number of cut-off corrections decreased by a factor of 0.986. This suggests cut-off corrections rate increases when the humidity lowers. Therefore, it indicates that humidity in the laboratory is also a factor that affects HLA typing results.

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Comparison of Three Third-Generation Anti-HCV Enzyme Immunoassay Tests (세가지 효소면역측정 시약을 이용한 C형 간염 바이러스 항체 검사의 비교)

  • Cho, Hee-Soon;Moon, Jin-Young;Lee, Chae-Hoon;Kim, Kyung-Dong
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.143-150
    • /
    • 1998
  • The aim of this study was to evaluate domestic enzyme immunoassay(EIA) kit 'LG RCD 3.0' (LG) for the detection of antibody to hepatitis C virus(anti-HCV) in comparision with Axsym HCV version 3.0(Axsym), Cobas Core anti-HCV EIA(Cobas). Cobas kit shows better clear distinction between positive and negative by signal/cutoff ratio(S/C), but it also reveal relatively high false positive rate. The concordance rate of test results between LG and Axsym was 96.2%, between LG and Cobas was 95.5%, and total agreement between three EIA kit was 93.9%. LG were relative poor distinction between positive and negative results, but it could be applied clinically as a screening tool for hepatitis C in general population. The SIC of one false negative result by LG was 0.91, and false positive were less than 4.0, therefore we concluded it is necessary to confirm by immunoblotting assay when SIC were between 0.8 and 4.0.

  • PDF

Analysis of Mammography for Patient with Breast Cancer (유방암 환자를 대상으로 한 유방영상검사 분석)

  • Mo, Eun-Hui;Lim, Cheong-Hwan;Lee, Sang-Ho;Jung, Hong-Ryang;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The purpose of this study is to evaluate the diagnostic accuracy of breast cancer from mammography images and to investigate the characteristics of patients who was diagnosed as a breast cancer. The subjects for this study were 85 patients who underwent breast imaging test with screen-film method and investigated from March 2010 to October 2010. The average age of the subjects is 51.9 years old. The 43.5% of onsets were located at the upper outer quadrant (UOQ). In terms of the age group, group for 40-49 ages were highest 37.6 (32/85)%. As for breast composition, fatty and dense breast were 30.6% (26/85) and 69.4% (59/85) respectively. The average age of the patients with fatty breast is 62.4 years old, whereas those with dense breast was 46.5 years old. The false negative rate of mammography images was 27.1% (23/85) and the sensitivity of mammography was 72.9% (62/85). The false negative rate of the patients with dense breast was 32.2% (19/59). the sensitivity of them was 67.8% (40/59).

Role of enzyme immunoassay for the Detection of Helicobacter pylori Stool Antigen in Confirming Eradication After Quadruple Therapy in Children (소아에서 4제요법 후 enzyme immunoassay에 의한 Helicobacter pylori 대변 항원 검출법의 유용성에 대한 연구)

  • Yang, Hye Ran;Seo, Jeong Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Purpose: The Helicobacter pylori stool antigen (HpSA) enzyme immunoassay is a non-invasive test for the diagnosis and monitoring of H. pylori infection. But, there are few validation studies on the HpSA test after eradication in children. The aim of this study was to assess the diagnostic accuracy of HpSA enzyme immunoassay for the detection of H. pylori to confirm eradication in children. Methods: From January 2001 to October 2003, 164 tests were performed in 146 children aged 1 to 17.5 years (mean $9.3{\pm}4.3$ years). H. pylori infection was confirmed by endoscopy-based tests (rapid urease test, histology, and culture). All H. pylori infected children were treated with quadruple regimens (Omeprazole, amoxicillin, metronidazole and bismuth subcitrate for 7 days). Stool specimens were collected from all patients for the HpSA enzyme immunoassay (Primier platinum HpSA). The results of HpSA tests were interpreted as positive for $OD{\geq}0.160$, unresolved for $$0.140{\leq_-}OD$$<0.160, and negative for OD<0.140 at 450 nm on spectrophotometer. Results: 1) One hundred thirty-one HpSA tests were performed before treatment. The result of HpSA enzyme immunoassay showed three false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value of HpSA enzyme immunoassay before treatment were 96.4%, 97.1%, 90%, and 99%, respectively. 2) Thirty-three HpSA enzyme immunoassay were performed at least 4 weeks after eradication therapy. The results of HpSA enzyme immunoassay showed two false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value after treatment were 88.9%, 91.7%, 80%, and 95.7%, respectively. Conclusion: Diagnostic accuracy of the HpSA enzyme immunoassay after eradication therapy was as high as that of the HpSA test before eradication therapy. The HpSA enzyme immunoassay was found to be a useful non-invasive method to confirm H. pylori eradication in children.

  • PDF