• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.027 seconds

155.52 Mbps High Performance CMOS Receiver for STM-1 Application (STM-1급 155.52 Mbps 고성능 CMOS 리시버의 구현)

  • 채상훈;정희범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1074-1079
    • /
    • 1999
  • A high performance CMOS receiver for 155.52 Mbps STM-1 digital communication has been designed and fabricated. The ASIC operates properly with 155.52 MHz clock frequency in case of the data loss due to some system error such as transmission line open or data transfer fail. Also it operates properly in case the system starts after the power failure or system maintenance. The designed circuit has especially PLL based self oscillation loop which operates on abnormal environment which is added to main oscillation loop. The measured results show that the circuit operates well with 153.52 MHz clock frequency not only on normal environment but also on abnormal environment. Rms jitter of the PLL loop is about 23 ps.

  • PDF

Calcaneal Insufficiency Avulsion Fracture in a Well-Controlled Type 2 Diabetic Patient: A Case Report

  • Kim, Seong-Tae;Moon, Myung-Sang;Kwon, Ki-Tae;Park, Bong-Keun;Ha, Chang Won;Ahn, Jungtae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.2
    • /
    • pp.73-76
    • /
    • 2015
  • The calcaneal insufficiency avulsion fracture usually occurs in an area of fused apophysis in adults without significant history of trauma or overuse activities. It is an uncommon injury which has been described in patients with complicated diabetes, Charcot neuroarthropathy, amyloidosis with neuropathy, severe osteoporosis, and other conditions. Discussion of the issue of fracture location is still not sufficient. We report on a case of a 50-year-old male who experienced a non-traumatic diabetic calcaneal insufficiency fracture. Intraoperatively, a biopsy specimen was obtained from the exposed fracture site for histological study. We assume that the calcaneal fused apophyseal line is the weak point of failure due to various incomplete mixtures of trabecular bone, woven bone, and cartilaginous tissues, and may fail when repeated tensile stress is imposed.

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Technology of Inspection and Real-time Displacement Monitoring on Critical Pipe for Power Plant (발전용 고온 배관의 점검 및 실시간 변위감시 기술)

  • Hyun, Jung-Seob;Heo, Jae-Sil;Cho, Sun-Young;Heo, Jeong-Yeol;Lee, Seong-Kee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1177-1186
    • /
    • 2009
  • High temperature steam pipes of thermal power plant are subject to a severe thermal range and usually operates well into the creep range. Cyclic operation of the plant subjects the piping system to mechanical and thermal fatigue damages. Also, poor or malfunctional supports can impose massive loads or stress onto the piping system. In order to prevent the serious damage and failure of the critical piping system, various inspection methods such as visual inspection, computational analysis and on-line piping displacement monitoring were developed. 3-dimensional piping displacement monitoring system was developed with using the aluminum alloy rod and rotary encoder sensors, this system was installed and operated on the high temperature steam piping of "Y" thermal power plant successfully. It is expected that this study will contribute to the safety of piping system, which could minimize stress and extend the actual life of critical piping.

Experimental Studies on Comparison of Stress Corrosion Cracking Generation Due to Pipe Material Degradation in the Primary Stage of the Nuclear Power Plant (원전 1차 측 배관재질의 열화에 따른 응력부식균열 발생 비교 실험 연구)

  • Park, Kwang-Jin;Lee, Gyu-Young;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.108-113
    • /
    • 2007
  • In this report, stress corrosion cracking generation due to pipe material degradation in the primary stage of the nuclear power plant was investigated. Firstly, after artificially degrading the CF8A steel during 2, 4, and 6 months in actual temperature, $400^{\circ}C,$ assessed corrosion susceptibility of the degraded material following ASTM G5 standard. And next, the S.C.C. tests for the degraded material were conducted under the condition of $60^{\circ}C,$ 2wt.% H2BO3+Li70H solution, 0.8 oy. From the results, Corrosion rates linearly increased with degradation period and solution temperature increase. And both the raw material and the degraded materials were not failed in the S.C.C. test condition. In spite of long time test (about 3,900 hrs) under S.C.C. condition, surface pits or surface corrosion by the electro chemical reaction were not observed. And also, even though the nondestructive DCPD and ACPD methods were applied to on-line monitor the S.C.C. failure processes it was impossible because the surface pits and cracks were not generated.

  • PDF

Development of MEMS Accelerometer-based Smart Sensor for Machine Condition Monitoring (MEMS 가속도계 기반 기계 상태감시용 스마트센서 개발)

  • Son, Jong-Duk;Yang, Bo-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.448-452
    • /
    • 2007
  • Many industrial operations require continuous or nearly-continuous operation of machines, which if interrupted can result in significant financial loss. The condition monitoring of these machines has received considerable attention recent years. Rapid developments in semiconductor, computing, and communication with a remote site have led to a new generation of sensor called "smart" sensors which are capable of wireless communication with a remote site. The purpose of this research is the development of smart sensor using which can on-line perform condition monitoring. This system is addressed to detect conditions that may lead to equipment failure when it is running. Moreover it will reduce condition monitoring expense using low cost MEMS accelerometer. This sensor can receive data in real-time or periodic time from MEMS accelerometer. Furthermore, this system is capable for signal preprocessing task (High Pass Filter, Low Pass Filter and Gain Amplifier) and analog to digital converter (A/D) which is controlled by CPU. A/D converter that converts 10bit digital data is used. This sensor communicates with a remote site PC using TCP/IP protocols. Wireless LAN contain IEEE 802.11i-PSK or WPA (PSK, TKIP) encryption. Developed sensor executes performance tests for data acquisition accuracy estimations.

  • PDF

Changes of Tracheal Anastomosis Site in Growing Rats (흰쥐에서 기관절제 단단 문합부의 성장에 따른 변화)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.26 no.5
    • /
    • pp.343-348
    • /
    • 1993
  • Growth of suture line and anastomosis is required for long-term success after the tracheal and bronchial surgery in infant and pediatric patient. We used various suture materials in these cases, but the results were differ. To select the adequate suture material in tracheal surgery, we tried next. Tracheal anastomoses were performed in 150 Sprague Dawley rats, aged 4 to 8 [mean 5.8] weeks and weight 62 to 106[mean 83.6] gram, to compare polydioxanone[PDS] 7-0, polyglactin 910[Vicryl]7-0, and polypropylene [prolene] 8-0 suture materials. In 150 rats, only 29[20%] were lived over 300 days, and the weight was 250 to 320[mean 289.5]gram. Cross sectional area of the anastomoses and two or three tracheal rings below anastomosis site were measured under microscope, and calculated and compared as Hsieh`s equition. Cross-sectional area,anastomosis site/normal site 100, were 89.4 $\pm$ 5.34% in PDS group[n=9], 75.7 $\pm$ 6.06% in Vicrylgroup [n = 10], and 80.8$\pm$ 4.06% in Prolene group[n = 10]. Histopathologic studies were done for all autopsies or put in death around 300 days postoperatively. PDS absorblion was not seen 16 weeks after suture but disappeared over 24 weeks slide. Vicryl absorbtion was noted postoperative 8 to 16 weeks, with marked tissue reaction. Prolene showed least tissue reaction, but the suture material was persisted with regional fibrotic capsule.Causes of death were respiratory failure in 76 cases, tracheal rupture in 22 cases, hemorrhage, biting, starvation and etc. in 23 cases. With the brief review of literatures, we report the results.

  • PDF

Probabilistic Evaluation of Voltage Quality on Distribution System Containing Distributed Generation and Electric Vehicle Charging Load

  • CHEN, Wei;YAN, Hongqiang;PEI, Xiping
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1743-1753
    • /
    • 2017
  • Since there are multiple random variables in the probabilistic load flow (PLF) calculation of distribution system containing distributed generation (DG) and electric vehicle charging load (EVCL), a Monte Carlo method based on composite sampling method is put forward according to the existing simple random sampling Monte Carlo simulation method (SRS-MCSM) to perform probabilistic assessment analysis of voltage quality of distribution system containing DG and EVCL. This method considers not only the randomness of wind speed and light intensity as well as the uncertainty of basic load and EVCL, but also other stochastic disturbances, such as the failure rate of the transmission line. According to the different characteristics of random factors, different sampling methods are applied. Simulation results on IEEE9 bus system and IEEE34 bus system demonstrates the validity, accuracy, rapidity and practicability of the proposed method. In contrast to the SRS-MCSM, the proposed method is of higher computational efficiency and better simulation accuracy. The variation of nodal voltages for distribution system before and after connecting DG and EVCL is compared and analyzed, especially the voltage fluctuation of the grid-connected point of DG and EVCL.

Life Analysis and Reliability Prediction of Micro-Switches based on Life Prediction Method (수명예측 방법에 따른 마이크로스위치의 수명분석 및 신뢰도 예측)

  • Ji, Jung-Geon;Shin, Kun-Young;Lee, Duk-Gyu;Lee, Hi Sung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.7 no.1
    • /
    • pp.57-69
    • /
    • 2011
  • Reliability means that a product maintains its initial quality and performance at certain period of time(time, distance, cycle etc) under given condition without failure. Given conditions include both environmental condition and operating condition. Environmental condition means common natural environment such as temperature, humidity, vibration, and working condition means artificial environment such as voltage, current load, install place, hours of use, which occurs during using the product. In the field of railway vehicles, although components of railway vehicles with reliability are the trend of mandatory as persisting period of railway vehicles is extended, using components of railway vehicles is insufficient for the practical reliability assessment. but the meaning of the first railway operating agency to acquire the parts in the field, the data suggest the reliability of products if you can and can show the reliability of modular units and modular units can provide the reliability of if you can present reliability of the entire system is thought to be here In this study, lifespan of micro-switch for master controller is analyzed and prediction is performed based on its field data considering the special circumstances of railway vehicles operating agency, such as a large number of trains operates on the same line.