• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.029 seconds

Analyzing Survival Data by Proportional Reversed Hazard Model

  • Gupta, Ramesh C.;Wu, Han
    • International Journal of Reliability and Applications
    • /
    • v.2 no.1
    • /
    • pp.1-26
    • /
    • 2001
  • The purpose of this paper is to introduce a proportional reversed hazard rate model, in contrast to the celebrated proportional hazard model, and study some of its structural properties. Some criteria of ageing are presented and the inheritance of the ageing notions (of the base line distribution) by the proposed model are studied. Two important data sets are analyzed: one uncensored and the other having some censored observations. In both cases, the confidence bands for the failure rate and survival function are investigated. In one case the failure rate is bathtub shaped and in the other it is upside bath tub shaped and thus the failure rates are non-monotonic even though the baseline failure rate is monotonic. In addition, the estimates of the turning points of the failure rates are provided.

  • PDF

Assembly Performance Evaluation Using FACTOR / AIM for the Automobile Body Assembly Line (자동차 차체조립공정설계를 위한 시뮬레이션)

  • Hwang, Heung-Suk;Cho, Gyu-Sung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.1
    • /
    • pp.95-102
    • /
    • 2001
  • The design of automobile body assembly line is one of essential parts for improving the process performance. The major objective of this research is to develop a performance evaluation model for automobile assembly line using a closed queueing network(CQN) and simulation method. In this study we used a two-step approach to compute the performance of the assembly line : first, we used CQN model considering assembly line equipments and the line operating time under the assumption of no failure, and second we used a well-known simulator FACTOR/AIM. Finally we implemented this model on a K automobile company and we have shown the sample results of automobile body assembly line.

  • PDF

Service Failure, Service Recovery Activity and Satisfaction with Online Shopping Channel of Apparel Products (온라인 의류쇼핑에서 서비스 실패 경험 후 쇼핑채널의 회복노력에 따른 채널만족도)

  • Kang, Eun Jung;Lee, Kyu-Hye
    • Journal of Digital Convergence
    • /
    • v.11 no.2
    • /
    • pp.115-125
    • /
    • 2013
  • Unexpected consumer dissatisfaction emerges through rapid growth and expansion of on-line shopping channel. This research focused on the fashion online retail channels' negative aspect caused by service failure which possibly disappointed consumers. We also tried to seek for appropriate service recovery types based on frequently offered recovery types on-line. Data from college students were analyzed. Results indicate that fitting problem, insufficient information, product defect, inventory problem and slow delivery were the main service failure types in apparel e-shopping. Regression analysis identified that among these types, insufficient information, product defect, and slow delivery had significant influence on channel satisfaction after post recovery effort. Results also confirmed significant relationships between channel satisfaction and channel switching. Consumers perceived benefit level causes overall channel satisfaction level to rise while perceived risk leads to lower level of channel satisfaction. Choosing desirable service recovery activities in each service failure situations is necessary in order to raise consumer's channel satisfaction in online apparel shopping.

Determination of Deterioration and Damage of Porcelain Insulators in Power Transmission Line Through Mechanical Analysis (기계적 분석을 통한 송전용 자기 애자의 열화 판단 및 파손 부위에 대한 연구)

  • Son, Ju-Am;Choi, In-Hyuk;Koo, Ja-Bin;Kim, Taeyong;Jeon, Seongho;Lee, Youn-Jung;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.50-55
    • /
    • 2020
  • Porcelain insulators have been used for a long time in 154 kV power transmission lines. They are likely to be exposed to sudden failure because of product deterioration. This study was conducted to evaluate the quality of porcelain insulators. After stresses were applied, the damaged regions of aged insulators were investigated in terms of chemical composition, material structure, and other properties. For porcelain insulators that were in service for a long time, the mechanical failure load was 126 kN, whereas the average mechanical failure load was 167.3 kN for new products. It was also determined that corrosion occurred at the metal pin part due to the penetration of moisture into the gap between the pin and the ceramic. Statistical analyses of failure were performed to identify the portion of the insulators that were broken. Cristobalite porcelain insulators fabricated without alumina additives had a high failure rate of 54% for the porcelain component. In the case of the addition of Alumina (Al2O3) to the porcelain insulators to improve the strength of the ceramic component, a more frequent damage rate of the cap and pin of 73.3% and 27%, respectively, was observed. This study reports on the material component of SiO2 and the percentage of alumina added, with respect to the mechanical properties of porcelain insulators.

A study on the cause Analysis and solution of an overheated NGR of the Main Transformer (변압기 중성점 접지리액터 과열원인분석 및 해소방안에 관한 연구)

  • Park, Gil-Soo;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.262-267
    • /
    • 2011
  • In the power system, the transformer's neutral earth reactor line 1 grounding failure may occur. By limiting the magnitude of the failure grounding current flow, it will aid to reduce the failure of the transformer. Consequently, this also may avoid the failure of the disconnection of the industrial insulator line that cause by melting. Besides, utilizing the decreasing circuit breaker or others related equipment can use to avoid the possibility of explosion of the transformer. If the failure happen during the operation of the power system, a huge interference will definitely may occur. Therefore, by installing the DONGBUSAN S/S #3M.Tr neutral earth reactor among TOP and BOTTOM BRACE part in the power system, the causes of the rising temperature and reason of the over-current flow that cause by over-current can be analyze.

Crack Propagation in Earth Embankment Subjected to Fault Movement (단층 운동시 댐 파괴 거동 해석)

  • 손익준
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1988.06c
    • /
    • pp.3-67
    • /
    • 1988
  • Model studies on the response of homgeneous earth embankment dams subjected to strike-slip fault movement have been penomed via centrifuge and finite element analysis. The centrifuge model tests have shown that crack development in earth embankment experiences two major patters: shear failure deep inside the embankment and tension failure near the surface. The shear rupture zone develops from the base level and propagates upward continuously in the transverse direction but allows no open leakage chnnel. The open tensile cracks develop near the surface of the embankment, but they disappear deep in the embankment. The functional relationship has been developed based on the results of the centrifuge model tests incorporating tile variables of amount of fault movement, embankment geometry, and crack propagation extent in earth des. This set of information can be used as a guide line to evaluate a "transient" safety of the duaged embankment subjected to strike-slip fault movement. The finite element analysis has supplemented the additional expluations on crack development behavior identified from the results of the centrifuge model tests. The bounding surface time-independent plasticity soil model was employed in the numerical analysis. Due to the assumption of continuum in the current version of the 3-D FEM code, the prediction of the soil structure response beyond the failure condition was not quantitatively accurate. However, the fundamental mechanism of crack development was qualitatively evaluated based on the stress analysis for the deformed soil elements of the damaged earth embankment. The tensile failure zone is identified when the minor principal stress of the deformed soil elements less than zero. The shear failure zone is identified when the stress state of the deformed soil elements is at the point where the critical state line intersects the bounding surface.g surface.

  • PDF

Seismic behavior of steel reinforced concrete (SRC) joints with new-type section steel under cyclic loading

  • Wang, Qiuwei;Shi, Qingxuan;Tian, Hehe
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1561-1580
    • /
    • 2015
  • No significant improvement has been observed on the seismic performance of the ordinary steel reinforced concrete (SRC) columns compared with the reinforced concrete (RC) columns mainly because I, H or core cross-shaped steel cannot provide sufficient confinement for core concrete. Two improved SRC columns by constructing with new-type section steel were put forward on this background: a cross-shaped steel whose flanges are in contact with concrete cover by extending the geometry of webs, and a rotated cross-shaped steel whose webs coincide with diagonal line of the column's section. The advantages of new-type SRC columns have been proved theoretically and experimentally, while construction measures and seismic behavior remain unclear when the new-type columns are joined onto SRC beams. Seismic behavior of SRC joints with new-type section steel were experimentally investigated by testing 5 specimens subjected to low reversed cyclic loading, mainly including the failure patterns, hysteretic loops, skeleton curves, energy dissipation capacity, strength and stiffness degradation and ductility. Effects of steel shape, load angel and construction measures on seismic behavior of joints were also analyzed. The test results indicate that the new-type joints display shear failure pattern under seismic loading, and steel and concrete of core region could bear larger load and tend to be stable although the specimens are close to failure. The hysteretic curves of new-type joints are plumper whose equivalent viscous damping coefficients and ductility factors are over 0.38 and 3.2 respectively, and this illustrates the energy dissipation capacity and deformation ability of new-type SRC joints are better than that of ordinary ones with shear failure. Bearing capacity and ductility of new-type joints are superior when the diagonal cross-shaped steel is contained and beams are orthogonal to columns, and the two construction measures proposed have little effect on the seismic behavior of joints.

A Study on Microscopic Fractrue Behavior of Mortar Using Acoustic Emission (음향방출을 이용한 mortar 재료의 미시적 파괴거동에 관한 연구)

  • 이준현;이진경;장일영;윤동진
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.203-211
    • /
    • 1998
  • It is well recognized recently that acoustic emission, which is an elastic wave generated from rapid release of elastic energy in steressed solids, is very useful tool for on-line monitoring of microscopic behavior of deformation of material. In this study, three point bend test was performed to evaluate the microscopic damage progress during the loading and failure mechanism of mortar beam by monitoring the characteristic of AE signal. The relationship between AE characteristic and microscopic failure mechanism is discussed. In addition 2 dimensional AE source location based on triangular method was also done to monitor the intiation and propagation of micro crack around notch tip of mortar beam. It was shown that AE source location was very effective to predict the growth behavior of micro crack in mortar beam specimen.

Failure Behaviors Depending on the Notch Location of the Impact Test Specimens on the HAZ (용접열영향부 충격시험편 노치 위치에 따른 파괴거동)

  • Jang, Yun-Chan;Hong, Jae-Keun;Park, Ji-Hong;Kim, Dong-Wook;Lee, Young-Seog
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.706-711
    • /
    • 2007
  • Numerical studies were performed to examine the effects of notch location of impact specimens on the failure behavior of HAZ (heat affected zone) when Charpy V-notch impact test were made at a low temperature ($1^{\circ}C$). Carbon steel plate (SA-516 Gr. 70) with thickness of 25mm for pressure vessel was welded by SMAW (shielded metal-arc welding) and specimens were fabricated from the welded plate. Charpy tests were then performed with specimens having different notch positions of specimens varying from the fusion line through HAZ to base metal. A series of finite element analysis which simulates the Charpy test and crack propagation initiating at the tip of V-notch was carried out as well. The finite element analysis takes into account the irregular fusion line and non-homogenous material properties due to the notch location of the specimen in HAZ. Results reveals that the energies absorbed during impact test depend significantly on the notch location and direction of specimen. Finite element analysis also demonstrates that the notch location of specimens, to a great extent, influences the reliability and consistency of the test.

  • PDF

Comparison of the Two Layout Structures in Automotive Body Shops Considering Failure Distributions (자동차 차체공장에서 고장분포를 고려한 두 종류 배치구조에 대한 비교)

  • Kim, Ha Seok;Wang, Guan;Shin, Yang Woo;Moon, Dug Hee
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.5
    • /
    • pp.470-480
    • /
    • 2015
  • There are many challenges in manufacturing system for new factory construction. Although factories produce same product, the layout of each factory may be different. The body shop in an automotive factory is a typical flow line with assembly, but the layout concept of the line varies among factories. In this paper, two types of layouts in the body shops of automotive factories, one for layered build and the other for modular build, are compared using simulation study. The simulation experiments indicate that the modular build layout is better than the layered build layout with respect to production rate. The effects of various failure distributions on the throughputs are also investigated, and some insights are suggested regarding the layout concept.