• Title/Summary/Keyword: fading estimation

Search Result 288, Processing Time 0.024 seconds

Phase Tracking for Orthogonal Frequency Division Multiplexing Systems (직교 주파수 분할 다중화 시스템을 위한 위상 오차 추적)

  • Jeon, Tae-Hyun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.12 s.354
    • /
    • pp.61-67
    • /
    • 2006
  • This paper proposes the algorithm for tracking of the residual phase errors incurred by carrier frequency offset and sampling frequency offset in the orthogonal frequency division multiplexing (OFDM) systems which are suitable for high data rate wireless communications. In the OFDM systems the subcarriers which are orthogonal to each other are modulated by digital data and transmitted simultaneously. The carrier frequency offset causes degradation of signal to noise ratio(SNR) performance and interference between the adjacent subcarriers. The errors in the sampling timing caused by the sampling frequency difference between the transmitter and the receiver sides also cause a major performance degradation in the OFDM systems. The residual error tracking and compensation mechanism is essential in the OFDM system since the carrier and the sampling frequency offset cause the loss of orthogonality resulting in the system performance loss. This paper proposes the scheme where the channel gain and the payload data information are reflected in the residual error tracking process which results in the reduction of the estimation error and the tracking performance improvements under the frequency selective fading wireless channels.

Time Constant Control Method for Hopfield Neural Network based Multiuser Detector of Multi-Rate CDMA system (시정수 제어 기법이 적용된 Multi-Rate CDMA 시스템을 위한 Hopfield 신경망 기반 다중 사용자 검출기)

  • 김홍열;장병관;전재춘;황인관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.6A
    • /
    • pp.379-385
    • /
    • 2003
  • In this paper, we propose a time constant control method for sieving local minimum problem of the multiuser detector using Hopfield neural network for synchronous multi-rate code division multiple access(CDMA) system in selective fading environments and its performance is compared with that of the parallel interference cancellation(PIC). We also assume that short scrambling codes of 256 chip length are used an uplink, suggest a simple correlation estimation algorithm and circuit complexity reduction method by using cyclostationarity property of short scrambling code.It is verified that multiuser detector using Hopfield neural network more efficiently cancels multiple access interference(MAI) and obtain better bit error rate and near-far resistant than conventional detector.

Link Scheduling Method Based on CAZAC Sequence for Device-to-Device Communication (D2D 통신 시스템을 위한 CAZAC 시퀀스 기반 링크 스케줄링 기법)

  • Kang, Wipil;Hwang, Won-Jun;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.4
    • /
    • pp.325-336
    • /
    • 2013
  • FlashLinQ, one of the typical D2D communication systems developed by Qualcomm, considers a single-tone communication based distributed channel-aware link scheduling method to realize the link scheduling process with low control overheads. However, considering the frequency selective fading effect of practical multi-path channel, the single-tone based SIR estimation causes a critical scheduling error problem because the received single-tone signal has quite different channel gain at each sub-carrier location. In order to overcome this problem, we propose a novel link scheduling method based on CAZAC (Constant Amplitude Zero Auto-Correlation) sequence for D2D communication system. In the proposed method, each link has a unique offset value set for the generation of CAZAC sequences. CAZAC sequences with the cyclic offsets are transmitted using multiple sub-blocks in the entire bandwidth, and then each device can obtain nearly full-band SIR using a good cyclic cross-correlation property of CAZAC sequence.

A Cross-Layer based Video Transmission Scheme using Efficient Bandwidth Estimation in IEEE 802.11e EDCA (IEEE 802.11e EDCA에서 효율적인 대역폭 측정을 통한 Cross-Layer 기반의 비디오 전송 기법)

  • Shin, Pil-Gyu;Lee, Sun-Hun;Chung, Kwang-Sue
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.3
    • /
    • pp.173-182
    • /
    • 2008
  • Promoting quality of streaming service in wireless networks has attracted intensive research over the years. Instable wireless channel condition causes high transmission delay and packet loss, due to fading and interference. Therefore, they lead to degrade quality of video streaming service. The IEEE 802.11 Working Group is currently working on a new standard called IEEE 802.11e to support quality of service in WLANs. And several schemes were proposed in order to guarantee QoS. However, they are not adaptable to network condition. Accordingly, they suffered video quality degradation, due to buffer overflow or packet loss. In this paper, to promote quality of video streaming service in WLANs, we propose a cross-layer architecture based on IEEE 802.11e EDCA model. Our cross-layer architecture provides differentiated transmission mechanism of IEEE 802.11e EDCA based on priority of MPEG-4 video frames and adaptively controls the transmission rate by dropping video frames through the efficient bandwidth estimation based on distinction of each AC. Through the simulation, proposed scheme is shown to be able to improve end-to-end qualify for video streaming service in WLANs.

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

Photochromic lens for patients with photophobia and estimation of clinical trial efficacy (광시증 환자를 위해 개발된 광변색렌즈와 임상 효과 평가)

  • Ha, Jin-Wook;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • Photochromic lens is the color changing lens from colorlessness to colorness when exposed to UV light. It can protect eyes from UV-B light which cause the cataract and can be used as sunglass in the summer since it can cut off 70~80% of sun light. Surface coating technique was used to develop lens which has 70% light transmittance and of which fading time of color change is within 5 min. Various color lenses were developed so that these had various color such as blue, green, brown, violet, yellow and red etc. Lens has an excellent physical properties, 100% adhesion and 4~5H hardness. The chemical and the scratch resistance of this lens were the greatest and the thermal stability was also higher. The clinical trial of developed lens were applied to 65 patients who had photophobia by various reasons at ophthalmology of Soonchunhyang University Hospital. Results showed that glaring was significantly reduced and the visual health were remarkably improved. Especially, anti-glaring effect in the night was great for the patient who had the LASIK operation. Protection of UV-B and blue light also can prevent the patient from cataract and the yellowish crystalline lens at old ages. Through the result of clinical. trial, we know that photochromic lens could be a new technique for both cure and precaution of photophobia.

  • PDF

Analysis of Research Papers Published by the Korean Journal of Hospice and Palliative Care (The First Issue~2012) (한국 호스피스.완화의료학회지 게재논문 분석(창간호~2012년))

  • Hwang, In Cheol;Kang, Kyung-Ah;Ahn, Hong Yup
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.2
    • /
    • pp.74-79
    • /
    • 2013
  • The purpose of this paper is to suggest a direction for future studies based on the analysis of the articles published in the Korean Journal of Hospice and Palliative Care from 1998 to 2012. A total of 240 articles (51 reviews, 189 original) were examined in three five-year groups. Categories of analysis include authors' background (profession, region) and general characteristics and qualitative aspects of the original paper (participants, topic, study design, data analysis, ethical consideration, multidisciplinary approach, research funds and sample size estimation). While the journal publishes more of articles than before, it is mainly due to the increase in the number of review articles, not original articles. As for study topics, healthcare industry and physical symptoms were most frequently studied. The disparity in authors' regional background is fading, and more articles are published by nurses than before. Moreover, more studies are funded while fewer papers tend to adopt a multidisciplinary approach or focus on care givers. Also, in terms of a study design, the number of experimental and methodological studies has slightly increased. In the qualitative aspect, studies considered ethical issues and collected participation consent, and fewer studies reported an estimated sample size. In data analysis, post-adjustment comparison decreased, and new analytical methods are increasingly used. Our results indicate the need to conduct research with more extensive scientific data in various fields of hospice and palliative care.

High Density Tilapia Culture in a Recirculating Water System without Filter Bed (무여과순환수 탱크 이용 Tilapia의 고밀도 사육실험)

  • KIM In-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.2
    • /
    • pp.59-67
    • /
    • 1983
  • An experiment on the rearing of tilapia stocked in closed recirculating tanks eliminating biological filter beds was carried out at the Fish Culture Experiment Station of the National Fisheries University of Pusan, from May 18 through October 21, 1982, and the growth rates, feed conversion, water quality, spawning prevention and space utilization efficiency were discussed. Finally discussed is the feasibility on the establishment of commercial production units. On the water quality, the water temperature ranged from $22.8^{\circ}C\;to\;29.1^{\circ}C$, and total ammonia arround 10 ppm or slightly up. Maintaining phytoplankton bloom was not successful probably because of the active consumption by the heavily stocked tilapia. Several attempts were made by changing the culture water with green water from a nearby earthen pond with results of fading-away in a couple of days. Feed conversions were relatively high ranging from 0.9 to 1.2 except for experiment 1 when the fish were not fully recovered from weakened wintering state. The feed used was partly laboratory prepared $25\%$ protein diet and mostly commercially available $39\%$ protein carp feed. Spawning was completely controlled during the experiment, resulting from density effect, which ranged from 10kg to 40.7kg per square meter with water depth of 0.5 to 0.6m. Space utilization efficiency was very high. Daily net production from the experiment division 3, which showed the highest result, was 6.206 kg per tank, which is calculated 3,235 metric tons per hectare per year, This time, water temperature ranged from 27.8 to $29.1^{circ}C$, average being $28.4^{circ}C$, and total ammonia arround 10 ppm. An estimation for the commercial set-up of the production system based on the results of experiment divisions which had initial stocking rate $15\;kg/m^2$ or up, is made. If the total facility, 8 tanks comprising $56\;m^2$ in surface area, is used for the present study, the yield would become 5,639 kg from 200 day rearing, which would be possible under double sheets vinyl house without additional heating, and it is thought feasible in the economic view point, when 10 or more units are operated.

  • PDF