• Title/Summary/Keyword: facility condition

Search Result 947, Processing Time 0.032 seconds

Starting Characteristics Study of Scramjet Engine Test Facility(SETF) (스크램제트 엔진 시험설비의 시동특성 연구)

  • Lee, Yang-Ji;Kang, Sang-Hun;Oh, Joong-Hwan;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.451-458
    • /
    • 2010
  • Unlike most aerodynamic wind-tunnel, Scramjet Engine Test Facility(SETF) of Korea Aerospace Research Institute should simulate enthalpy condition at a flight condition. SETF is a blow-down type, high-enthalpy wind tunnel. To attain a flight condition, a highly stagnated air comes into the test cell through a supersonic nozzle. Also, an air ejector of the SETF is used for simulating altitude conditions of the engine, and facility starting. SETF has a free-jet type test cell and this free-jet type test cell can simulate a boundary layer effect between an airplane and engine using facility nozzle, but it is too difficult to predict the nature of the facility. Therefore it is required to understand the starting characteristics of the facility by experiments. In this paper, the starting characteristics of the SETF and modifications of the ejector are described.

  • PDF

A Literature Review of Unmanned Aircraft System (UAS) Integrated Constructed Facility Condition Inspections (무인항공체계 기반 시설물 상태점검 최근 연구동향 분석)

  • Kwon, Jin-Hyeok;Yun, Jiyeong;Youn, JongYoung;Lee, Donghoon;Kim, Sungjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.172-173
    • /
    • 2021
  • In recent, unmanned Aircraft Systems (UAS) have been widely used for various purposes, such as safety inspection, facility condition inspection, progress monitoring, in the architecture engineering, and construction (AEC) industry. This technology can provide visual assets regarding the conditions of construction jobsites as well as constructed facilities during flying over the point of interests. With the significant interests in this advancement, the recent studies have presented how the UAS can be applied fro different types of facilities (e.g., buildings, power genereation systems, roads, or bridges) to inspect the current conditions of them for safe operations as well as public's safety. This study reviewed the receent studies to document their scientific findings and practical contributions, as well as provided the overview of further implications for future studies.

  • PDF

Establishing Unmanned Aircraft System(UAS)-based Facility Condition Monitoring Process through Benchmarking Analysis (벤치마킹 분석을 통한 무인항공시스템 기반 시설물 상태 모니터링 프로세스 수립 연구)

  • Kwon, Jin-Hyeok;Kim, Sungjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.101-102
    • /
    • 2022
  • The current facility condition monitoring has disadvantages such as a slow inspection cycle, a risk of human casualties, and the need for a lot of time and money as the size of the structure is larger, because human access is required with limited use. Drones can reduce the risk of human casualties due to their good accessibility, and can compensate for the shortcomings of the current method by enabling monitoring on a wide scale. The goal of this study is to provide the current domestic monitoring process through benchmarking according to the recent research case of the US Department of Transportation (DOT) to suggest a process suitable for the domestic situation and the direction of future improvement measures.

  • PDF

A Study on User's Condition and Environmental Analysis of University Sports Facilities - Focused on the D University Sports Center by the Post Occupancy Evaluation - (대학체육시설의 이용현황 및 환경분석 조사연구 - D 대학 체육관의 거주후 평가를 중심으로 -)

  • Kim, Sung-Kee
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.6
    • /
    • pp.3-10
    • /
    • 2010
  • The purpose of this study is to examine the state of utilization in sport facilities at a university and drew up the improvement plan for all students. To accomplish this work, the survey of the 445 students(male 221, female 224) were collected. The collected data were analyzed through the frequency analysis. All of sports facility is used for wide range of student who like to use as their leisure in order to learn variety experience for spending their spare time. Also sports facility of university accomplish social education function to all member of university. Having sports facility for university can also work as a promotion and new impression to people its university image as well as welfare for staff. Especially, excellent sports facility at university can provide public service to local people where university is located. Having sport facility at university is directly related to development of university in many way, university is required to implement effective program for operating sport facility at university.

A Study on the Space Constitution for the Complex of Educational Facilities - Focused on Public Space Formation for Composition of Complex with Welfare Facilities for the Aged - (교육시설의 복합화를 위한 공간구성에 관한 연구 - 고령자 복지시설과의 복합화를 위한 공용공간구성을 중심으로 -)

  • Kim, Jin-Mo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.3
    • /
    • pp.27-35
    • /
    • 2007
  • The purpose of this research is to analyzing the welfare function of the senior citizen with similar type of compounding the school facility, to analyze the problematical point of present condition. And also propose the spatial constitution which the student and the regional senior citizen are easy to utilize on the basis of the result. In a type of educational facility composition, it became clear that a ratio and the inflection order that elderly welfare facilities occupied of vacant class room were low. In other words, in composition of a school facilities, elderly welfare facilities can be said to be an important problem. As a result of having analyzed an existing compound facilities, there was limited interchange of student and a the aged. In addition, there were problems such as learning environment by an intersection of circulation. Therefore, composition of educational facility and elderly welfare facilities is not space composition that is intersection of simple specification function. In other words, a program of the common space which is necessary for the local community formation is necessary. Setting of semi-public area proposes the function of the existing facility and actual condition of spatial use in prerequisite.

Develop Test Facility of High Altitude Environment for Kick Motor (Kick Motor용 고공환경 모사 시험 설비 개발)

  • Kim, Sang-Heon;V.A, Bershadskiy;Yu, Byung-Il;Kim, Yong-Wook;Oh, Seung-Hyub;Park, Jeong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.707-710
    • /
    • 2008
  • The method suggested in this thesis is the safe and economic method when testing rocket engine because ground test facility copies high altitude. We have decided to use the schematic of testing facility based on already known design method and test result, and we have decided the test condition for ground firing test of solid fuel. In addition the pressure of nozzle exit area is 0.1bar, we have designed the testing facility structure to test in this condition. Moreover, we have designed to reduce the accident probability.

  • PDF

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(I) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(I))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Hyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.244-246
    • /
    • 2002
  • In this paper, We studied about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the enclosure of electrical facility which is connected to grounding system.

  • PDF

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(II) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(II))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.247-249
    • /
    • 2002
  • In this paper, We studied, about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the other outdoor electrical facility which is disconnected to grounding system.

  • PDF

An Improved Facility Management System for Public Facility Management Corporations (공공 시설관리기관의 시설관리시스템 개선에 관한 연구)

  • Kim, ChangDuk;Lee, HyunChul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.1
    • /
    • pp.32-42
    • /
    • 2018
  • The importance of facility maintenance management cannot be overemphasized in that not only the value but also the performance of the facility is determined by the level of maintenance. The maintenance cost of the facility ranges from 3 to 10 times the initial construction cost depending the type and use of the facility over the life span. This maintenance importance is increased for the group of facilities and even more critical when the facilities compete for the limited budget with the limited resources such as manpower and equipment. This study analyzed sixteen public facility management corporations primarily for three items: 1) facility management system, 2) long-term rehabilitation plan, 3) the rehabilitation selection system. This paper provides and recommends the key elements of the facility maintenance management system based on the analysis of the sixteen corporations.

Specific Process Conditions for Non-Hazardous Classification of Hydrogen Handling Facilities

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.416-420
    • /
    • 2021
  • Hazardous area classification design is required to reduce the explosion risk in process plants. Among the international design guidelines, only IEC 60079-10-1 proposes a new type of zone, namely zone 2 NE, to prevent explosion hazards. We studied how to meet the zone 2 NE grade for a facility handling hydrogen gas, which is considered as most dangerous among explosive gases. Zone 2 NE can be achieved considering the grade of release, as well as the availability and effectiveness of ventilation, which are factors indicative of the facility condition and its surroundings. In the present study, we demonstrate that zone 2 NE can be achieved when the degree of ventilation is high by accessing temperature, pressure, and size of leak hole. The release characteristic can be derived by substituting the process condition of the hydrogen gas facility. The equations are summarized considering relation of the operating temperature, operating pressure, and size of leak hole. Through this relationship, the non-hazardous condition can be realized from the perspective of inherent safety by the combination of each parameter before the initial design of the hydrogen gas facility.