• Title/Summary/Keyword: facet analysis

Search Result 140, Processing Time 0.021 seconds

Technical Modification and Comparison of Results with Hirabayashi's Open-door Laminoplasty

  • Kim, Young-Sung;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Chong-Oon;Park, Hyeon-Seon;Hyun, Dong-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.168-172
    • /
    • 2007
  • Objective : Hirabayashi's open-door laminoplasty is a good procedure to use to treat patients with myelopathy of the cervical spine; however, the authors have experienced problems in maintaining an open-window in cervical spines after the surgery. The authors developed a modified method of the expanded open-door laminoplasty and compared the radiological and clinical results with those of the classical method. Methods : In the modified method, wiring fixation with lateral mass screws on the contra lateral-side instead of fixing the paraspinal muscle or facet joint, as in the classical methods, was used in the open window of the cervical spine. Fifteen patients with cervical myelopathy were treated using the classical method and 12 patients were treated using the modified method. Preoperative and postoperative clinical conditions were assessed according to the Japanese Orthopedic Association (JOA) score. The radiological results were compared with the preoperative and postoperative computed tomography (CT) findings. Results : In both methods, the clinical results revealed a significant improvement in neurological function (p<0.001). Image analysis revealed that the cervical canals were continuously expanded in patients treated using the modified methods. However, authors have observed restenosis during the follow-up periods in 4 patients treated using the original method. Progression to deformity and spinal instability were not observed in any of the patients in the radiological results. Conclusion : Although analysis with a larger population and a longer follow-up period needs to be undertaken, our modified open-door laminoplasty has shown an advantage in better maintaining an open window in comparison with the Hirabayashi's open-door laminoplasty.

CC의 구조적 분석을 통한 분류자동화 원리유도

  • 이경호
    • Journal of Korean Library and Information Science Society
    • /
    • v.15
    • /
    • pp.113-151
    • /
    • 1988
  • The enumerative classification schemes do not represent the tiny mass of knowledge embodied in a article in a periodical or in a chapter or a paragraph of a book. But today's information centers regard a tiny spot of knowledge embodied in a article as a class. we call this micro-thought. But the enumerative classification are manual systems, it cannot be a n.0, pplied to the automation of classification. The purpose of this study is to build a general principle for the automatic book-classification which can be put to use in library operation, and to present a methodology of the automatic classification for the library. The methodology used is essentially theoretical, Published works by and about Ranganathan, especially 6th edition of the CC were studied, analyzed. The principle of automatic book classification derived from the analysis of colon classification and facet combinations. The results of this study can be summarized as follows ; (1) This study confined the fields of library science and agriculture. (2) This study represent a general principles for the automatic book classification of library science and agriculture. (3) Program flowcharts are designed as a basis of system analysis and program procedure in library science and agriculture. (4) The principles of the automatic classification in library, science is different from that of agriculture. (5) Automatic book classification can be performed by the principle of faceted classification, by inputting the title and subject code into a computer. In addition, the expected value from the automatic book-classification is as follows (1) The prompt and accurate of classification is possible. (2) Though a book is classified in any library, it can have same classification number. (3) The user can retrieve the classification code of a book for which he or she wants to search through dialogue with the computer. (4) Since the concept coordination method is employed, a tiny mass of knowledge embodied in a article in a periodical or in a chapter or a paragraph of a book can be represented as a class. (5) By performing automatic book-classification, the automation of library operation can be completed.

  • PDF

Biomechanical Analysis of the Implanted Constrained and Unconstrained ICR Types of Artificial Disc using FE Model (순간중심 고정식 및 이동식 인공디스크 적용에 대한 유한요소 모델을 이용한 생체역학적 분석)

  • Yun Sang-Seok;Jung Sang-Ki;Kim Young-Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.4 s.181
    • /
    • pp.176-182
    • /
    • 2006
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical changes with its implantation were rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, a nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Biomechanical analysis was performed for two different types of artificial disc having constrained and unconstrained instant center of rotation(ICR), ProDisc and SB Charite III model. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, forces on the spinal ligaments and facet joint, and stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400N were compared. The implanted model showed increased flexion-extension range of motion compared to that of intact model. Under 6Nm moment, the range of motion were 140%, 170% and 200% of intact in SB Charite III model and 133%, 137%, and 138% in ProDisc model. The increased stress distribution on vertebral endplate for implanted cases could be able to explain the heterotopic ossification around vertebral body in clinical observation. As a result of this study, it is obvious that implanted segment with artificial disc suffers from increased motion and stress that can result in accelerated degenerated change of surrounding structure. Unconstrained ICR model showed increased in motion but less stress in the implanted segment than constrained model.

Decision of Neural Network Architecture for Software Development Effort Estimation using Prior Information (사전 정보를 이용한 소프트웨어 개발노력 추정 신경망 구조 결정)

  • 박석규;유창열;박영목
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.9
    • /
    • pp.1191-1198
    • /
    • 2001
  • An increasingly important facet of software development is the ability to estimate the associate cost and effort of development early in the development life cycle. Most of the proposed models are based upon a combination of intuition, expert judgement, and regression analysis of empirical data. Overall, the work has failed to produce any single model that can be applied with a reasonable degree of success to a variety of environments. This paper presents a neural network (NN) model that related software development effort to software size measured in function element types. The heuristic approach is applied to decide the number of hidden neurons in NN from the relationship between input-output pairs. The research describes appropriate NN modeling in the context of a case study for 24 software development projects. Also, this paper compared the NN model with a regression analysis model and found the NN model has better accuracy.

  • PDF

A Study on Faceted Navigation in Next-Generation Library Catalog (차세대 도서관 목록에서의 패싯 내비게이션에 관한 연구)

  • Yoo, Yeong-Jun
    • Journal of the Korean Society for information Management
    • /
    • v.28 no.3
    • /
    • pp.13-30
    • /
    • 2011
  • Faceted navigation has brought a lot of changes to traditional library catalog and is one of the resource discovery interfaces in next-gen library catalog. Faceted navigation usually divides too much retrieved results into some relevant facets for user's convenient navigation. The faceted navigation of 9 libraries adopting resource discovery interfaces was analyzed in this article. The terms are much broader or different from the users' terms so that the users can't properly use the facets. It is essential to maintain consistency with using the terms to provide users with faceted navigation service and this study has found how exactly authority work was done in analysis of the author facets. Also, public libraries introducing faceted navigation need to consider including some facets for various users and university libraries need to consider detailed division of resource types.

Survey of Sonoanatomic Distances For Lumbar Medial Branch Nerve Blocks in Healthy Volunteers

  • Gharaei, Helen;Imani, Farnad;Solaymani-Dodaran, Masoud
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.133-138
    • /
    • 2014
  • Background: The precise knowledge of anatomy and the region of transverse process (TP) and superior articular processes (AP) and their distance from the skin are important in blocking and treating lumbar facet syndrome. Evaluation of these anatomic distances from 3rd and 5th lumbar vertebrae in both sides and in different body mass index (BMI) in healthy volunteers might improve knowledge of ultrasound (US) lumbar medial branch nerve blocks (LMBB). Methods: Bilateral US in the 3rd and 5th lumbar vertebrae of 64 volunteers carried out and the distance between skin to TP and skin to AP was measured. These distances were compared on both sides and in different BMI groups. The analysis was done using SPSS 11. Analysis of variance was used to compare the means at three vertebral levels (L3-L5) and different BMI groups. P values less than 0.05 were considered statistically significant. The paired t-test was used to compare the mean distance between skin to TP and skin to AP on both sides. Results: The distance between skin to TP and skin to AP of 3rd vertebrae to 5th vertebrae was increased in both right and left sides (P < 0.001) from up to down. The mean distance from skin to TP were greater on the left side compared to the right in all three vertebral levels from L3 to L5 (P values 0.014, 0.024, and 0.006 respectively). The mean distance from skin to TP and the skin to AP was statistically significant in different BMI groups (P < 0.001). Conclusions: We found many anatomic distances which may increase awareness of US guided LMBB.

Structural characteristics of Zachery treated turquoise (Zachery 처리 터키석의 표면 특성 평가)

  • Kwon, Ki-Ran;Bang, Sin-Young;Park, Jong-Wan;Shim, Kwang-Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 2009
  • The surface characteristics of Zachery-treated turquoise stones have been studied in detail with a comparison of natural and plastic-impregnated turquoise. The SEM-EDS analysis exhibited that Zachery-treated turquoise was characterized by the uniform distribution of potassium element through the specimen and did not show the sharp crystalline $SiO_2$ facet and boundary phase which are common in natural ore. The potassium element shown in the Zachery-treated turquoise seemed to be occurred during the treatment process for the improvement of durability. The bar-shaped crystals observed in the pore was found to be a feature of Zachery treated turquoise and are expected to influence on their stability and durability, while the pore sizes in turquoise stones depends on the parameter of the treatment procedure.

Analysis of the Calcaneocuboid Joint Involvement in Intraarticular Calcaneal Fractures (관절내 종골 골절에서 종입방 관절 침범 분석)

  • Shin, Won-Ju;Yang, Sang-Hoon;Park, Hong-Ki
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.42-47
    • /
    • 2006
  • Purpose: This study was performed to analyze the characteristics of calcaneocuboid joint involvement in intraarticular calcaneal fractures. Materials and Methods: Total number of 92 patients (111 cases) who underwent operation for intraarticular calcaneal fractures between Jan. 2000 and Oct. 2005 were included in this study. The preoperative computed tomographs of the subjects were retrospectively reviewed to analyze calcaneocuboid joint involvement. Results: It was revealed that 63 cases (56.8%) involved calcaneocuboid joint; 29cases (46.0%) showed type 1 (undisplaced or minimally displaced type, articular gap ${\le}1\;mm$), 16 cases (25.4%) exhibited type 2 (moderately displaced type, articular gap ${\ge}2\;mm$), 7 cases (11.1%) were included in type 3 (comminuted type) and 11 cases (17.5%) belonged to type 4 (fracture and dislocation). 48 out of 63 cases belonged to Sanders classification II and III that involved calcaneocuboid joint and included 25 cases (52.1%) of type 1 and 14 cases (29.2%) of type 2. Among 15 out of 63 cases included in Sanders classification IV, 4 (26.7%) showed type 1 and 6 (40.0%) belonged to type 4. According to our results, Sanders classification allowed to predict pattern of the involvement of calcaneocuboid joint (P<0.05). However, there was no statistically significant relationship between degree of posterior facet joint injuries and calcaneocuboid joint involvement (P>0.05). Conclusion: Calcaneocuboid joint involvement in intraarticular calcaneal fractures was common and more than half showed severe injuries. We concluded that further studies on the involvement of calcaneocuboid joint should be performed prior to surgical treatment of intraarticular calcaneal fractures.

  • PDF

Variation of Axial Tension-Compression Fatigue Characteristics by UNSM on Ti-6Al-4V (Ti-6Al-4V재의 UNSM처리에 의한 축인장압축피로특성변화)

  • Suh, Chang-Min;Cho, Sung-Am;Pyoun, Young-Sik;Suh, Min-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.42-48
    • /
    • 2011
  • The present study makes three original contributions to nanoskinned Ti-6Al-4V materials. The nanoskins were fabricated on Ti-6Al-4V material using various surface treatments: deep rolling (DR), laser shot peening (LSP), and ultrasonic nanocrystal surface modification (UNSM). These surface treatments are newly developed techniques and are becoming more popular in industrial fields. A fatigue strength comparison at up to 106 cycles was conducted on these nanoskinned Ti-6Al-4V materials. Fatigue tests were carried out using MTS under axial loading tension-compression fatigue (R = -1, RT, 5 Hz, sinusoidal wave). The analysis of the crack initiation patterns in the nanoskinned Ti-6Al-4V materials found an interior originating crack pattern and surface originating crack type. Microscopic observation was mainly used to investigate the fatigue fractured sites. These surface modification techniques have been widely adopted, primarily because of the robust grade of their mechanical properties. These are mainly the result of the formation of a large-scale, deep, and useful compressive residual stress, the formation of nanocrystals by the severe plastic deformation (SPD) at the subsurface layer, and the increase in surface hardness.

The Quality of Life of Patients with Good Outcomes after Anterior Circulation Aneurysm Surgery Assessed by the World Health Organization Quality of Life Instrument-Korean Version

  • Jang, Kyung-Sool;Han, Young-Min;Jang, Dong-Kyu;Park, Sang-Kyu;Park, Young Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.179-186
    • /
    • 2012
  • Objective : Even in the patients with neurologically good outcome after intracranial aneurysm surgery, their perception of health is an important outcome issue. This study aimed to investigate the quality of life (QOL) and its predictors of patients who had a good outcome following anterior circulation aneurysm surgery as using the World Health Organization Quality of Life instrument-Korean version. Methods : We treated 280 patients with 290 intracranial aneurysms for 2 years. This questionnaire was taken and validated by 99 patients whose Glasgow Outcome Scale score was 4 and more and Global deterioration scale 3 and less at 6 months after the operation, and 85 normal persons. Each domain and facet was compared between the two groups, and a subgroup analysis was performed on the QOL values and hospital expenses of the aneurysm patients according to the type of craniotomy, approach, bleeding of the aneurysm and brain injury. Results : Aneurysm patients showed a lower quality of life compared with control patients in level of independence, psychological, environmental, and spiritual domains. In the environmental domain, there were significant intergroup differences according to the type of craniotomy and the surgical approach used on the patients (p<0.05). The hospital charges were also significantly different according to the type of craniotomy (p<0.05). Conclusion : Despite good neurological status, patients surgically treated for anterior circulation aneurysm have a low quality of life. The craniotomy size may affect the QOL of patients who underwent an anterior circulation aneurysm surgery and exhibited a good outcome.