• Title/Summary/Keyword: facet analysis

Search Result 140, Processing Time 0.024 seconds

Fabrication and analysis of $1.3\mum$ spot-size-converter integrated laser diodes (광모드변환기가 집적된 $1.3\mum$ SC-FP-LD 제작 및 특성 해석)

  • 심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.271-278
    • /
    • 2000
  • We have fabricated and analyzed the lasing characteristics of 1.3$\mu\textrm{m}$ Spot-Size-Converter (SSC) integrated Fabry-Perot (FP) laser diodes, which are very promising light sources for optical subscriber networks. SSC-LDs has been developed by BIB (buttjoint-built-in) coupling and selective MOVPE growth. High-performances were achieved such as the slope efficiency from the SSC facet of 0.23-0.32 mW/mA, the full-width at the half maximum of the far-field pattern (FFP) of 9.5$^{\circ}$~12.3$^{\circ}$, the alignment tolerances of $\pm$2.3$\mu\textrm{m}$ and $\pm$2.5$\mu\textrm{m}$ within the extra-coupling loss of 1 dB for the vertical and parallel directions, respectively. These experimental results were compared to theoretical ones in order to clarify the operational problems and give a good design direction of the fabricated SSC-LDs. It was revealed that an asymmetric output power from the facets, an irrelevancy of FFP and the waveguide structure around SSC facet region, and a poor temperature characteristics were originated from the scattering in the BIB and SSC sections and SHB effect in the active section for the first time.t time.

  • PDF

Single mode yield analysis of complex-coupled DFB lasers above threshold for various coupling coefficient ratios and facet reflectivity combinations (문턱 전류 이상에서 Complex-Coupled DFB 레이저 다이오드의 여러 가지 결합 계수 비와 양 단면 반사율 조합에 따른 단일 모드 수율 해석)

  • 김부균;김상택;전재두
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.521-529
    • /
    • 2003
  • For complex-coupled (CC) DFB lasers, we found that there might be little correlation between the single mode yields at threshold and above threshold. At threshold, the single mode yield considering f number of in-phase (IP) CC DFB lasers is the same as that of anti-phase (AP) CC DFB lasers. However, the single mode yield as a function of injection current above threshold of IP CC DFB lasers is much different from that of AP CC DFB lasers. In the case of IP CC DFB lasers, the single mode yield increases as the coupling coefficient ratio (CR) increases, while, in the case of AP CC DFB lasers, the single mode yield decreases rapidly regardless of CR as the injection current increases. In the case of AR-HR combinations, the effect of AR ref1ectivity on the single mode yield increases as the coupling strength decreases. As the coupling strength decreases, the CR at which the increase rate of the single mode yield starts to decrease, increases, and the maximum single mode yield increases. Single mode yields of AR-HR and AR-AR combinations are larger than those of AR-CL and CL-CL combinations.

What is the Role of Epidural Injections in the Treatment of Lumbar Discogenic Pain: A Systematic Review of Comparative Analysis with Fusion

  • Manchikanti, Laxmaiah;Staats, Peter S.;Nampiaparampil, Devi E.;Hirsch, Joshua A.
    • The Korean Journal of Pain
    • /
    • v.28 no.2
    • /
    • pp.75-87
    • /
    • 2015
  • Background: Lumbar discogenic pain without pain mediated by a disc herniation, facet joints, or the sacroiliac joints, is common and often results in chronic, persistent pain and disability. After conservative treatment failure, injection therapy, such as an epidural injection, is frequently the next step considered in managing discogenic pain. The objective of this systematic review is to determine the efficacy of lumbar epidural injections in managing discogenic pain without radiculopathy, and compare this approach to lumbar fusion or disc arthroplasty surgery. Methods: A systematic review of randomized trials published from 1966 through October 2014 of all types of epidural injections and lumbar fusion or disc arthroplasty in managing lumbar discogenic pain was performed with methodological quality assessment and grading of evidence. The level of evidence was based on the grading of evidence criteria which, was conducted using 5 levels of evidence ranging from levels I to V. Results: Based on a qualitative assessment of the evidence for both approaches, there is Level II evidence for epidural injections, either caudal or lumbar interlaminar. Conclusions: The available evidence suggests fluoroscopically directed epidural injections provide long-term improvement in back and lower extremity pain for patients with lumbar discogenic pain. There is also limited evidence showing the potential effectiveness of surgical interventions compared to nonsurgical treatments.

An Analysis on the Application of Functional Mask for Protection in Fashion Mask (보호용 기능성 마스크를 응용한 패션 마스크 분석)

  • Choi, Jung-Hwa
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.851-861
    • /
    • 2013
  • This study analyzed the fashionable characteristics of functional fashion mask types. This study reviewed the literature on masks and analyzed fashion photos found in fashion books, fashion collections and on internet fashion sites. The results were categorized into four characteristics. Integration of structure and function showed mask designs that connected to the hood and portable items. It represented the reflection of nomadic life, liberation, obscurity and the consciousness of discomfort. Signs of playfulness showed mask hybrids and animal images, the mask hybrids and humanoid images, the printing of animal characters, body parts and unusual material hybrids. It represented the liberation from a fixed identity, the loss of seriousness, the reduction of tension and the pursuit of pleasure and freedom. The duplicity of aggression and protection showed a futuristic or aggressive helmet facemask, an enclosed mask of intensive color, and the morphological hybrid of a disgusting or aggressive motif. It represented the end of human weakness, the desire of new self-expression and the longing of superhuman power. Fanciful decoration showed masks with glittery decoration, sunglasses with luxury decoration material, a medical facemask made of lace material and fanciful printing. It showed one facet of extreme consumption, the creation of new personality and value, the pursuit of high quality and a mutual coexistence of status and anonymity.

Vapor Phase Deposition and Characterization of Diamond Thin Films on Refractory Metals (내열금속 기판위에 다이아몬드 박막의 증착과 특성분석)

  • 홍성현;형준호
    • Korean Journal of Crystallography
    • /
    • v.5 no.1
    • /
    • pp.39-50
    • /
    • 1994
  • Diamond thin films were deposited on silicon, molybdebum, titanum and tugsten substrates, and were chlwntnizen using scanning electron microscopy, X-ray diffraction analysis and Raman spectroscopy. From the result of experiment in various deposition periods, it was found that found that were nucleated and grown on interlayed carbide layers, which were formed on refractory metal substrates at the initial stage of.

  • PDF

Impact Analysis of the Cervical Spin using a Finite Element Model (유한요소 모델을 이용한 충격력에 따른 경추부의 응답특성 해석)

  • 김영은;박덕용;이춘기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.249-257
    • /
    • 1999
  • A three dimensional finite model of a human neck has been developed in an effort to study the mechanics of cervical spin while subjected to vertical impact. This model consisting of the vertebrae from C1 through C7 including posterior element and ligaments was constructed by 2mm thick transverse CT cross-sections and X-ray film taken at lateral side. Geometrical nonlinearity was also considered for the large deformation on the disc. ABAQUS package was used for calculation and its results were verified comparing with responses of a model under static loading condition with published in-vitro experimental data. There were more cervical fracture in the restrained (compression) mode than in the nonrestrained (flexion-compression and extension-compression) mode. Upper cervical(C1-C2) injuries were observed under compression-extension modes, while lower cervical injuries occurred undjer compression-flexion modes. Posterior ligament distraction without bony damage at the upper cervical spin(C1-C2) were observed secondary to C5-C7 trauma in compression-flexion modes.

  • PDF

Selecting a Synthesizable RISC-V Processor Core for Low-cost Hardware Devices

  • Gookyi, Dennis Agyemanh Nana;Ryoo, Kwangki
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1406-1421
    • /
    • 2019
  • The Internet-of-Things (IoT) has been deployed in almost every facet of our day to day activities. This is made possible because sensing and data collection devices have been given computing and communication capabilities. The devices implement System-on-Chips (SoCs) that incorporate a lot of functionalities, yet they are severely constrained in terms of memory capacitance, hardware area, and power consumption. With the increase in the functionalities of sensing devices, there is a need for low-cost synthesizable processors to handle control, interfacing, and error processing. The first step in selecting a synthesizable processor core for low-cost devices is to examine the hardware resource utilization to make sure that it fulfills the requirements of the device. This paper gives an analysis of the hardware resource usage of ten synthesizable processors that implement the Reduced Instruction Set Computer Five (RISC-V) Instruction Set Architecture (ISA). All the ten processors are synthesized using Vivado v2018.02. The maximum frequency, area, and power reports are extracted and a comparison is made to determine which processor is ideal for low-cost hardware devices.

The Effect of pH and temperature on the Morphology of Aluminum Hydroxides formed by Hydrolysis Reaction (알루미늄의 수화 반응시 pH와 온도에 따른 형상 변화)

  • 오영화;이근회;박중학;이창규;김흥회;김도향
    • Journal of Powder Materials
    • /
    • v.11 no.2
    • /
    • pp.118-123
    • /
    • 2004
  • A formation of aluminum hydroxide by hydrolysis reaction in the water has been studied by using nano aluminum powder fabricated by pulsed wire evaporation(PWE) method. The hydroxide type and morphology depending on temperature and pH were examined by structural analysis. The Boehmite($Al_2O_3$.$H_2O$ or AIO(OH)) was predominantly formed in high temperature region over 4$0^{\circ}C$, while the Bayerite($Al_2O_3$.$H_2O$ or $Al(OH)_3$) below $30^{\circ}C$ of hydrolysis temperature. The Boehmite formation was preferred to the Bayerite in acidic solution in the same hydrolysis temperature. The slowly formed Bayerite phase showed facet crystalline structure, while the fast formed Boehmite was fine fiber with a large aspect ratio of several nm in diameter and several hundred nm in length, and with much larger specific surface area(SSA) than that of Bayerite. The highest SSA was about $420m^2$/g.

Analysis of biomechanical change of adjacent motion segment of the lumbar spine with an implanted artificial disc (인공추간판 적용 시 인접 운동 분절에서의 변화 분석)

  • Kim Y.E.;Yun S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.244-247
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain and used clinically, biomechanical change with its implantation seldom studied. To evaluate the effect of artificial disc implantation on the biomechanics of lumbar spinal unit, nonlinear three-dimensional finite element model of L1-L5, S1 was developed and strain and stress of vertebral body and surrounding spinal ligaments were predicted. Intact osteoligamentous L1-L5, S1 model was created with 1-mm CT scan of a volunteer and known material property of each element were applied. This model also includes the effect of local muscles which was modeled with pre-strained spring elements. The intact model was validated with reported biomechanical data. Two models implanted with artificial discs, SB Charite or Prodisc, at L4/5 via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments, facet joint contact force with $2\sim12$ Nm flexion-extension moment.

  • PDF

Cross-Correlation of Oscillations in A Fragmented Sunspot

  • Lee, Kyeore;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.45.3-46
    • /
    • 2018
  • Oscillations in a sunspot are easily detected through the Doppler velocity observation. Although the sunspot oscillations look erratic, the wavelet analysis show that they consist of successive wave packets which have strong power near three or five minutes. Previous studies found that 3-min oscillation at the chromosphere is a visual pattern of upward propagating acoustic waves along the magnetic field lines. Resent multi-height observations help this like vertical study, however, we also focus on horizontal facet to extend three dimensional understand of sunspot waves. So, we investigate a fragmented sunspot expected to have complex wave profiles according to the positions in the sunspot observed by the Fast Imaging Solar Spectrograph. We choose 4 points at different umbral cores as sampling positions to determine coherence of oscillations. The sets of cross-correlation with three and five minutes bandpass filters during a single wave packet reveal interesting results. Na I line show weak correlations with some lags, but Fe I and Ni I have strong correlations with no phase difference over the sunspots. It is more remarkable at Ni I line with 3-min bandpass that all sets of cross-correlation look like the autocorrelation. We can interpret this as sunspot oscillations occur spontaneously over a sunspot at photosphere but not at chromosphere. It implies a larger or deeper origin of 3-min sunspot oscillation.

  • PDF