• Title/Summary/Keyword: eye size

Search Result 338, Processing Time 0.022 seconds

Development of compound eye image quality improvement based on ESRGAN (ESRGAN 기반의 복안영상 품질 향상 알고리즘 개발)

  • Taeyoon Lim;Yongjin Jo;Seokhaeng Heo;Jaekwan Ryu
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.2
    • /
    • pp.11-19
    • /
    • 2024
  • Demand for small biomimetic robots that can carry out reconnaissance missions without being exposed to the enemy in underground spaces and narrow passages is increasing in order to increase the fighting power and survivability of soldiers in wartime situations. A small compound eye image sensor for environmental recognition has advantages such as small size, low aberration, wide angle of view, depth estimation, and HDR that can be used in various ways in the field of vision. However, due to the small lens size, the resolution is low, and the problem of resolution in the fused image obtained from the actual compound eye image occurs. This paper proposes a compound eye image quality enhancement algorithm based on Image Enhancement and ESRGAN to overcome the problem of low resolution. If the proposed algorithm is applied to compound eye image fusion images, image resolution and image quality can be improved, so it is expected that performance improvement results can be obtained in various studies using compound eye cameras.

Red-Eye Removal Using an Inpainting Method (인페인팅 기법을 이용한 적목현상 제거)

  • Yoo, Seung-Hwan;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.365-366
    • /
    • 2007
  • In this paper, a novel correction method of red-eye effect is proposed. Conventional methods simply reduce red components in red-eye regions, not considering the expanded size of a pupil, thus the correction results can be unnatural. In the proposed method, an exemplar-based inpainting method is used for reducing the pupil region and filling the iris texture instead. Experimental results show that the proposed method is effective and its correction results look more natural than those of conventional methods.

  • PDF

Correlation between Palpebral Fissure and Exophthalmos of The Elder Women in Korea (한국노인여성의 검열과 안구돌출의 상관관계)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.3
    • /
    • pp.427-434
    • /
    • 2015
  • Purpose: This study was to investigate the relationship between the palpebral fissure and the exophthalmos in an elder women population in Korea subjects with normal eye status. Methods. From November 2014 to July 2015, The author analyzed the morphological values in 81 Korean elder women population. The clinical test was performed using the Hertel exophthalometer and verner califer. Analysis of data were described using the spss 20 and Pearson's test. Results. The mean age of the 81 subjects (162 eyes) was (73.938+/8.585)mm. The mean value of palpebral fissure was (5.673+/-2.065)mm in width and (24.179+/-4.409)mm in height. The mean value of exophthalmos was (5.537+/-2.151)mm. There were a significant relationship(P>0.01) in the mean size between the width and height in palpebral fissure. Also, there were a significant relationship(P>0.01) in the mean size between the palpebral fissure width and exophthalmos. Also, there were a significant relationship(P>0.01) in the mean size between the palpebral height width and exophthalmos. However, there were not significant relationship(P>0.01) in the mean size between the palpebral fissure width and exophthalmos in right eye. On the other hand, The relationship between right eye and left eye of the palpebral fissure and exophthalmos was similar results. Conclusions. In this study, these results suggested that the palpebral fissure and exophthalmos was a significant relationship in the mean value of morphologic characters in Korean elder women population.

Analysis of cross-population differentiation between Thoroughbred and Jeju horses

  • Lee, Wonseok;Park, Kyung-Do;Taye, Mengistie;Lee, Chul;Kim, Heebal;Lee, Hak-Kyo;Shin, Donghyun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.8
    • /
    • pp.1110-1118
    • /
    • 2018
  • Objective: This study was intended to identify genes positively selected in Thoroughbred horses (THBs) that potentially contribute to their running performances. Methods: The genomes of THB and Jeju horses (JH, Korean native horse) were compared to identify genes positively selected in THB. We performed cross-population extended haplotype homozygosity (XP-EHH) and cross-population composite likelihood ratio test (XP-CLR) statistical methods for our analysis using whole genome resequencing data of 14 THB and 6 JH. Results: We identified 98 (XP-EHH) and 200 (XP-CLR) genes that are under positive selection in THB. Gene enrichment analysis identified 72 gene ontology biological process (GO BP) terms. The genes and GO BP terms explained some of THB's characteristics such as immunity, energy metabolism and eye size and function related to running performances. GO BP terms that play key roles in several cell signaling mechanisms, which affected ocular size and visual functions were identified. GO BP term Eye photoreceptor cell differentiation is among the terms annotated presumed to affect eye size. Conclusion: Our analysis revealed some positively selected candidate genes in THB related to their racing performances. The genes detected are related to the immunity, ocular size and function, and energy metabolism.

Classification between Intentional and Natural Blinks in Infrared Vision Based Eye Tracking System

  • Kim, Song-Yi;Noh, Sue-Jin;Kim, Jin-Man;Whang, Min-Cheol;Lee, Eui-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.601-607
    • /
    • 2012
  • Objective: The aim of this study is to classify between intentional and natural blinks in vision based eye tracking system. Through implementing the classification method, we expect that the great eye tracking method will be designed which will perform well both navigation and selection interactions. Background: Currently, eye tracking is widely used in order to increase immersion and interest of user by supporting natural user interface. Even though conventional eye tracking system is well focused on navigation interaction by tracking pupil movement, there is no breakthrough selection interaction method. Method: To determine classification threshold between intentional and natural blinks, we performed experiment by capturing eye images including intentional and natural blinks from 12 subjects. By analyzing successive eye images, two features such as eye closed duration and pupil size variation after eye open were collected. Then, the classification threshold was determined by performing SVM(Support Vector Machine) training. Results: Experimental results showed that the average detection accuracy of intentional blinks was 97.4% in wearable eye tracking system environments. Also, the detecting accuracy in non-wearable camera environment was 92.9% on the basis of the above used SVM classifier. Conclusion: By combining two features using SVM, we could implement the accurate selection interaction method in vision based eye tracking system. Application: The results of this research might help to improve efficiency and usability of vision based eye tracking method by supporting reliable selection interaction scheme.

Development of a Color Stereo Head-Eye System with Vergence (눈동자 운동이 가능한 컬러 스테레오 머리-눈 시스템의 개발)

  • HwangBo, Myung;You, Bum-Jae;Oh, Sang-Rok;Lee, Jong-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2370-2372
    • /
    • 1998
  • Recently we have developed an active stereo head-eye system with vergence, name it KIST HECter(Head-Eye System with Colored Stero Vision), based on the analysis of human's neck and eye motion at visual behavior. Our HECter is a five degree-of-freedom system composed of pan and tilt motion in neck part and independent vergence motion of binocular cameras and commonly shared elevation axis in eye part. And stereo vision Provides two color image, which are processed by powerful each TMS32080 vision board. The shape and size are designed to be almost same as human face. The ability to vergence has significant importance and gives many beneficial merits. On its mechanical implementation we adapt a non-parallelogram 4-bar linkage mechanism since it provides high accuracy in transfering motion and enables compact and flexible design.

  • PDF

A Study on Neuro Sports Marketing by using Pupil's Size of Men: Focusing on Basketball Game (남성의 동공 크기를 이용한 뉴로 스포츠 마케팅의 접근 방법: 농구 경기를 중심으로)

  • Ko, Eui-Suk;Song, Ki-Hyeon;Cho, Soo-Hyun;Kim, Jong-Ha
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.31-40
    • /
    • 2017
  • The present study used one of research techniques which is eye gaze tracking for neuromarketing. When pupil's size of men dilated over than three sigma (0.135%), the interest and eye movement in observation were measured. According to statistical analysis of previous studies, three sigma range is meaningful therefore sigma range was used as operational definition because 'pupil dilatation' is difficult to be define in eye gaze tracking data. Pictures of basketball games were selected as visual stimuli and 90% effective ratio of total 7,200 data were calculated. Thus, 29 of 34 participants were used for test. Pupil's size was calculated by applying pupil's width and height into a formular; [Pupil's size = Pupil width/2${\times}$Pupil height/$2{\times}{\pi}$]. In conclusion, billboard utilized for sports marketing had meaningless effects because gaze frequency to basketball player and surrounding environment was higher than that to billboard when participantsas game spectators diltaed their pupil's size over than three sigma. Thus, it was required using new marketing strategies like neuromarketing to increase utility through the present study.

The Experimental Study of Efficacy in Using Fel Ursi, Bovis Calculus & Moschus Pharmacopuncture Solution as Eye Drop (점안용 웅담.우황.사향약침액의 유효성 평가)

  • Seo, Hyung-Sik
    • Journal of Pharmacopuncture
    • /
    • v.12 no.3
    • /
    • pp.41-47
    • /
    • 2009
  • Objectives : This experimental study was performed to investigate the efficacy of Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : After administering Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis, MIC(Minimum Inhibition Concentration) and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : There was no response to MIC on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) after Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution was medicated. Conclusions : The present study suggests that Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution dosen't have anti-bacterial effects on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

Estimation of Correlation Coefficients between Histological Parameters and Carcass Traits of Pig Longissimus Dorsi Muscle

  • Ryu, Y.C.;Rhee, M.S.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.3
    • /
    • pp.428-433
    • /
    • 2004
  • The aim of this study was to investigate the histochemical parameters of muscle fibers, and to estimate the correlation between these histological parameters and carcass traits in pigs. A total of 230 crossbred Duroc$\times$(Yorkshire$\times$Landrace) pigs (149 gilts and 81 castrated male pigs) was evaluated. Carcass traits (carcass weight, backfat thickness, and loin eye area), muscle fiber size (crosssectional area, diameter, and perimeter), muscle fiber number (density of fibers/$mm^2$ and total number of fibers), and fiber type composition (percentages of myofibers and relative areas of each fiber type) were evaluated. Mean cross-sectional area (CSA) and type IIB fiber CSA were positively correlated to carcass weight, backfat thickness and loin eye area. Mean fiber CSA was mostly related to type IIB CSA (r=0.98) as a result of the high percentage of type IIB fibers in the longissimus muscle. Correlations between fiber diameters and perimeters were also high, and showed similar results with CSA. Mean fiber density was negatively correlated to carcass weight (r=-0.24), backfat thickness (r=-0.18) and loin eye area (r=-0.27). To the contrary, total fiber number was positively correlated with carcass weight (r=0.27) and loin eye area (r=0.53). Carcass weight and loin eyZe area were not significantly related to muscle fiber composition. For backfat thickness, there was an opposition between type IIA percentage, which was positively related and type IIB percentage, which was negatively related. Fiber type composition of type I and IIA fibers were negatively correlated to that of type IIB fibers (r=-0.67 to -0.74). In the present study, carcass weight and loin eye area were positively correlated to CSA and negatively correlated to fiber density. But, these relationships were generally low. The fiber density was strongly affected by muscle fiber size and the total fiber number was affected either by CSA of muscle fiber and loin eye area. Fiber type composition was much more related to their numerical abundance than their CSA.

Development of a Fall Detection System Using Fish-eye Lens Camera (어안 렌즈 카메라 영상을 이용한 기절동작 인식)

  • So, In-Mi;Han, Dae-Kyung;Kang, Sun-Kyung;Kim, Young-Un;Jong, Sung-tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.97-103
    • /
    • 2008
  • This study is to present a fainting motion recognizing method by using fish-eye lens images to sense emergency situations. The camera with fish-eye lens located at the center of the ceiling of the living room sends images, and then the foreground pixels are extracted by means of the adaptive background modeling method based on the Gaussian complex model, which is followed by tracing of outer points in the foreground pixel area and the elliptical mapping. During the elliptical tracing, the fish-eye lens images are converted to fluoroscope images. the size and location changes, and moving speed information are extracted to judge whether the movement, pause, and motion are similar to fainting motion. The results show that compared to using fish-eye lens image, extraction of the size and location changes. and moving speed by means of the conversed fluoroscope images has good recognition rates.

  • PDF