• Title/Summary/Keyword: eye contact

Search Result 211, Processing Time 0.03 seconds

Comparison of Stereopsis by Influence Factors in Induced Aniseikonia (유발 부등상시에서 영향인자에 따른 입체시의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.465-471
    • /
    • 2013
  • Purpose: This study was conducted to research effects of influence factors on stereopsis of induced aniseikonia in emmetropia. Methods: 20 college students (a mean age of $22.50{\pm}2.72$ years, 14 males, 6 females) were selected as subjects and all of them had no ocular disease or systemic disease, the refractive correction of spherical equivalent within ${\pm}0.50$ D, the corrected visual acuity of 1.0 or better and the aniseikonia values less than 1% by AWAYA. Subject's dominant eye was checked by Hole in card method and contact lenses of -7.00 ~ +7.00D were fitted to cause anisometropia in dominant eye or non-dominant eye, respectively. And then aniseikonia was induced with spectacles to correct refractive error by contact lenses. Stereopsis was measured by Random Dot Stereo Acuity Test with LEA symbols$^{(R)}$ (Vision Assessment Corporation$^{TM}$, USA). Results: Stereopsis was remarkably reduced by inducing aniseikonia, with induced aniseikonia in dominant eye, with higher diopter of wearing contact lenses to induce anisometropia, with spectacles lenses correction of minus power after fitting contact lenses with plus power and in case of men. Conclusions: It should be considered to correct anisometropia that aniseikonia could cause reduction of stereopsis.

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

Generation of an eye-contacted view using color and depth cameras (컬러와 깊이 카메라를 이용한 시점 일치 영상 생성 기법)

  • Hyun, Jee-Ho;Han, Jae-Young;Won, Jong-Pil;Yoo, Ji-Sang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1642-1652
    • /
    • 2012
  • Generally, a camera isn't located at the center of display in a tele-presence system and it causes an incorrect eye contact between speakers which reduce the realistic feeling during the conversation. To solve this incorrect eye contact problem, we newly propose an intermediate view reconstruction algorithm using both a color camera and a depth camera and applying for the depth image based rendering (DIBR) algorithm. In the proposed algorithm, an efficient hole filling method using the arithmetic mean value of neighbor pixels and an efficient boundary noise removal method by expanding the edge region of depth image are included. We show that the generated eye-contacted image has good quality through experiments.

An Investigation of Eye Inconvenience due to the Wearing and Management of Lens of Female University Students (여대생의 렌즈 착용과 관리 행위에 따른 눈의 불편감 조사)

  • Jang, Hyun-Jung;Jeon, Hye Won
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.183-190
    • /
    • 2020
  • This study was designed to investigate the current state of lens wearing and care, and to investigate eye discomfort according to the care method. Data of 209 female college students wearing lenses for more than 1 year were analyzed using the SPSS / WIN 22.0 program. 40.2% of female students wear lenses every day and 97.1% wear all day. However, only 45.4% of students washed it daily, and only 17.7 % used protein remover during wash, which resulted in poor management. 98.1% of students complained of discomfort due to the lens, and the Ocular Surface Index (OSDI) scored 42.88 ± 15.25, which was classified as a severe dry eye and threatened eye health. Therefore, it is necessary to improve students' awareness of lens management, and periodical lens inspection and management education are needed.

A study on using practice of contact lens and side effects (연성콘택트렌즈 착용자의 실태와 부작용에 대한 연구)

  • Kang, Hyang Nyeo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.69-73
    • /
    • 2002
  • This questionnaire studied the status of wear and care for soft contact lens, of 200students wearing loft contact lens. 50% of man wore soft contact lens, 8 hours and 52% of woman wore soft contact lens 10 hours per a day, 51% of man has worn soft contact lens 3 years 45% of woman has worn soft contact lens 3 year. For the side effects of wearing contact lens 39% of man soft contact lens wearers experienced eye congestion, 72% of woman soft contact lens wearers dryness eyes.

  • PDF

The morphological study of Cornea in Man College Students (남자대학생들의 각막 형태 연구)

  • Kim, Douk Hoon;Yoo, Jae Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • The physiology and morphology of cornea has effected on the ocular refractive status. Therefore the measurement of the anterior corneal surface by keratometer is used the treatment of the spectacles and contact lens by optician, optometrist, and ophthalmologist. Furthermore, currently the most corneal topographic mapping system have used the clinical optical shop, eye research center, and eye hospital. Because this method have a very fine data comparative to the previous instrument. The authors have measurement the cornea of the man college students by the corneal topographic mapping method. Especially this data will applied the clinical practice for the contact lens fitting. Especially in Korea, many man college students use the contact lens for the visual acuity and a beauty. Therefore the contact lens wear have increase per every year.

  • PDF

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

The Kinematic Patterns of Walking according to Obstacle's Height (장애물 높이에 따른 보행의 운동형상학적 변화에 대한 연구)

  • Chung, Hyung-Kuk
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.3
    • /
    • pp.55-63
    • /
    • 2008
  • Background : The Purposes of this study were to understand difference between free walking and obstacle over walking through the naked eye and motion analysis device, and to review merits of obstacle walking training as item of functional assessment in clinical situations. Methods : All participants were male and performed 3 types of walking methods: free walking, obstacle over walking with low block(height=10cm, width=8cm), and obstacle over walking with high block(height=20cm, width=8cm). All walking were performed 3 trials respectively. Results : In the naked eye, initial contact with toes occurred more than heel strike in obstacle over walking, and the flexion angle of hip and knee were increased in obstacle over walking. On interpretations though motion analysis device, cadence, gait speed and weight accept were significant statistically(p<.05). Cadence and gait speed were decreased, and weight accept duration was increased in obstacle over walking. Rotation among three pelvic motions was significant statistically(p<.05), flexion among three hip motions was significant statistically(p<.05) and flexion among three ankle motions was significant statistically(p<.05). Rotation and flexion among three ankle motions was significant statistically(p<.05). Conclusion : Both the naked eye and interpretations of the device presented many difference between free walking and obstacle over walking. In overcrossing obstacles, many participants appeared walking strategy by perform initial contact with toes. Knee flexion was most significant statistically(p<.05) in obstacle over walking with 20cm block.

  • PDF