The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens

ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구

  • Received : 2007.08.13
  • Published : 2007.11.30

Abstract

The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

본 연구는 ez NANOsence II RGP 콘택트렌즈를 사용하여 굴절이상 눈의 피검자에 대한 시력과 각막에 미치는 임상적 검증을 하였다. 피검자는 성인 121명(남성 29인, 여성 92명; 연령은 17세와 43세 사이, 평균 22.86세)을 대상으로 실시하였다. 피검자는 콘택트렌즈 착용 전의 증상을 포함하는 문진을 실시하였고, 또한 콘택트렌즈 착용전후의 눈에 대한 자각과 타각증상 변화도 검진하였다. 시력측정은 콘택트렌즈를 착용하여 원거리에서 실시하였고, 굴절검사는 타각적 방법(Topcon KR-8100, Japan)으로 나안 상태에서 실시하였다. 입체시 검사는 Titmus fly(Stereo Optical Co., U.S.A)와 TNO(Tech, The Netherlands)로서 콘택트렌즈 착용 후 근거리에서 시행하였고, 대비감도 진단은 콘택트렌즈 착용 후 대비감도 챠드(pelli-Robertson, USA)로 1m 거리에서 실시하였다. 각막 지형도검사는 콘택트렌즈 착용 후 나안상태에서 ORB scan(Bausch Lomb, U.S.A.)을 사용하였다. 콘택트렌즈의 표면미세구조는 SEM(JSM-5800, Japan)을 이용해서 관찰하였고, 콘택트렌즈의 화학 성분은 EDS 프로그램을 사용해서 분석하였다. 연구 결과는 다음과 같다. 1. 렌즈의 착용 기간이 길수록 피검자는 대게 개선된 시각기능을 획득했다. 2. 렌즈 착용에 따른 눈의 부작용은 거의 없었다. 3. 피검자의 렌즈 사용은 잘하고 있다. 4. 렌즈 착용기간이 길수록 각막의 굴절 값은 약간 감소하고, 곡률반경은 약간 증가하며, 각막난시는 감소(P<0.01)하고, 각막의 중앙부 두께도 감소하였다. 5. 렌즈 사용 기간이 길수록, 입체시와 대비감도는 더욱 정상 값을 가졌다. 6. 각막지형도 분석에서 대부분 피검자들은 착용기간의 차이에도 비슷한 형태를 나타내었다. 7. 새로운 렌즈와 사용한 콘택트렌즈의 표면미세구조는 미세 형태에서 비슷한 상태이다. 8. 새로운 렌즈와 사용된 콘택트렌즈의 화학적 구성 성분은 거의 같았다. 결론적으로 본 연구는 새로운 것과 사용된 콘택트렌즈의 표면 미세구조와 화학적 구성성분이 유사함을 확인하였다. 또한 렌즈의 장기 착용에도 피검자의 시기능은 개선되고, 눈의 부작용은 적게 나타났으며, 각막난시 값은 감소되었다. 본 검사는 콘택트렌즈 착용자의 시각기능은 콘택트렌즈의 성분과 미세구조가 시각 기능에 관련이 있다고 여겨진다. 본 연구에서 저자들은 ez NANOsence II RGP 콘택트렌즈는 굴절 이상 눈의 교정시력에 좋은 효과가 있다고 추측된다.

Keywords