• Title/Summary/Keyword: extrusion force

Search Result 111, Processing Time 0.033 seconds

Evaluation of Structural Performance of Precast Prestressed Hollow-Core Slabs with Shear Reinforcement (전단철근이 배치된 프리캐스트 프리스트레스트 중공슬래브의 구조성능 평가)

  • Sang-Yoon Kim;Seon-Hoon Kim;Deuck-Hang Lee;Sun-Jin Han;Kil-Hee Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • This study aims to investigate the structural performance of hollow-core slab (HCS) memebers with 400 mm thickness. To this end, a total of four HCS specimens were fabricated based on the individual mold method to provide shear reinforcement, unlike the extrusion method. The key variables were chosen as the presence of topping concrete, core-filling concrete, and shear reinforcements. The crack patterns and load-displacement responses of the test specimens were analyzed in detail. Test results showed that inclined shear cracking occurred all the specimens, and that the specimen with shear reinforcement on the web of HCS unit had higher strength and ductility than the specimen without shear reinforcement. In particular, shear reinforcements placed on the web of HCS unit effectively resisted not only to vertical shear force but also to horizontal shear force between the interface of HCS unit and topping concrete. In addition, it was discovered that the method in which shear reinforcements are placed on the web of HCS unit is more effective in improving structural performance than core-filling method.

A THREE-DIMENSIONAL FEM COMPARISON STUDY ABOUT THE FORCE, DISPLACEMENT AND INITIAL STRESS DISTRIBUTION ON THE MAXILLARY FIRST MOLARS BY THE APPLICATION OF VAR10US ASYMMETRIC HEAD-GEAR (비대칭 헤드기어의 적용시 상악제 1 대구치에 나타나는힘과 변위 및 초기 응력분포에 관한 3차원 유한요소법적 연구)

  • Kim, Jong-Soo;Cha, Dyung-Suk;Ju, Jin-Won;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.25-38
    • /
    • 2001
  • The purpose of this study was to compare the force, the displacement and the stress distribution on the maxillary first molars altered by the application of various asymmetric head-gear. For this study, the finite element models of unilateral Cl II maxillary dental arch was made. Also, the finite element models of asymmetric face-bow was made. Three types of asymmetric face-bow were made : each of the right side 15mm, 25mm and 35mm shorter than the left side. We compared the forces, the displacement and the distribution of stress that were generated by application of various asymmetric head-gear, The results were as follows. 1. The total forces that both maxillary first molars received were similar in all groups. But the forces that mesially positioned tooth received were increased as the length of the outer-bow shortened, and the forces that normally positioned tooth received were decreased as the length of the outer-bow shortened. 2. In lateral force comparison, the buccal forces that normally positioned tooth received were increased as the length of the outer-bow shortened, and the buccal fortes that mesially positioned tooth received were decreased as the length of the outer-bow shortened. Though the net lateral force moved to the buccal side of normally positioned tooth as the length of the outer-bow shortened, both maxillary first molars received the buccal force. That showed 'Avchiai Expansion Effect' 3. The distal forces, the extrusion forces and the magnitudes of the crown distal tipping that mesially positioned tooth received were increased as the length of the outer-bow shortened, and the forces that normally positioned tooth received were decreased as the length of the outer-bow was shortened. 4. The magnitude of the distal-in rotation that normally positioned tooth received were increased as the length of the outer-bow was shortened. But, mesially positioned tooth show two different results. For the outer-bow 15mm shortened, mesially positioned tooth showed the distal-in rotation, hut for the outer-bow 25mm and 35mn shortened, mesially positioned tooth showed the distal-out rotation. Thus, the turning point exists between 15mm and 25mm. 5. This study of the initial stress distribution of the periodontal ligament at slightly inferior of the furcation area revealed that the compressive stress in the distobuccal root of the normally positioned tooth moved from the palatal side to the distal side and the buccal side successively as the length of the outer-bow shortened. 6. This study of the initial stress distribution of the periodontal ligament at slightly inferior of the furcation area revealed that the magnitudes of stress were altered but the total stress distributions were not altered in the mesiobuccal root and the palatal root of normally positioned tooth, and also three roots of mesially positioned tooth as the length of the outer-bow shortened.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON DURING DISTAL EN MASSE MOVEMENT OF THE MAXILLARY DENTITION (상악 치열의 치군 후방이동에 관한 3 차원 유한요소법적 연구)

  • Shin, Soo-Jung;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.563-580
    • /
    • 1998
  • This study was designed to analysis the displacement and stress distribution of individual tooth by orthodontic force during distal on masse movement of the maxillary dentition. In this study, three dimensional finite element analysis was used. Author made the finite element model of maxillary teeth, periodontal ligament, alveolar bone and bracket with anatomic and physiologic characteristics on computer. Author analysed and evaluated the displacement and stress distribution of individual tooth when extraoral force, Class II intermaxillary elastics, ideal arch wire, MEAW and tip back bend were used for distal on masse movement of the maxillary dentition. These analyses were also applied in the case of the maxillary second molar were not extracted. Author compared the results of the cases which maxillary second molar were extracted or not. The results were expressed quantitatively and visually. Author obtained following results, 1. When anterior headgear was applied, the posterior translation, posterior tipping, and vertical displacement of teeth were produced more in the anterior segment of the dentition. 2. When Class II intermaxillary elastics were applied in the ideal arch wire, the teeth displacement were usually produced in the anterior segment. But when tip back bend were added in the ideal arch wire, the orthodontic force produced by elastics were transmitted to the posterior segment. As increasing the tip back bend, posterior translation and lingual tipping of anterior teeth were decreased, posterior translation and tipping displacement of posterior teeth were increased, and extrusion of anterior teeth by Class II elastics were decreased 3. When MDAW and Class II elastics were applied, the teeth movement were sir flu with the case of ideal arch wire and Class II elastics, but more small and uniform teeth displacement were produced Compared with the ideal arch wire, posterior tipping of the posterior segment were more produced than lingual tipping displacement of the anterior segment. 4. When the maxillary second molar without orthodontic appliance existed, the displacement of maxillary first molar were decreased.

  • PDF

Finite element analysis of effectiveness of lever arm in lingual sliding mechanics (Lingual sliding mechanics의 lever arm 효과에 대한 유한요소분석)

  • Kim, Kyeong-Hee;Lee, Kee-Joon;Cha, Jung-Yul;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.324-336
    • /
    • 2011
  • Objective: The aim of this study was to conduct three-dimensional finite element analysis of individual tooth displacement and stress distribution when a posterior retraction force of 200 g was applied at different positions of the retraction hook on the transpalatal arch (TPA) of a molar, and over different lengths of the lever arm on the maxillary anterior teeth in lingual orthodontics. Methods: A three-dimensional finite element model, including the entire upper dentition, periodontal ligaments, and alveolar bones, was constructed on the basis of a sample (Nissan Dental Product, Kyoto, Japan) survey of Asian adults. Individual movement of the incisal edge and root apex was estimated along the x-, y-, and z-coordinates to analyze tooth displacement and von Mises stress distribution. Results: When the length of the lever arm was 15 mm and 20 mm, the incisal edge and root apex of the anterior teeth was displaced lingually, with a maximum lingual displacement at the lever arm length of 20 mm. When the posterior retraction hook was on the root apex, the molars showed distal displacement. When the length of the lever arm was 20 mm, anterior extrusion was reduced and the crown of the canine displaced toward the buccal side, in which case, the retraction hook was on the edge, rather than at the center, of the TPA. Conclusions: The results of the analysis showed that when 6 anterior teeth were retracted posteriorly, lateral displacement of the canine and lingual displacement of the incisal edge and root apex of the anterior teeth occur without the extrusion of the anterior segment when the length of the lever arm is longer, and the posterior retraction hook is in the midpalatal area.

Effects of Alkaline reagents on Textural and Sensory Properties of Ramyon (알카리제의 조성에 따른 라면의 조직감과 관능적 특성)

  • Jeong, Jae-Hong
    • Journal of the Korean Society of Food Culture
    • /
    • v.13 no.4
    • /
    • pp.261-266
    • /
    • 1998
  • In an attempt to evaluate the effects of alkali agents on properties of Ramyon, cooking quality, textural and sensory properties were examined. The shear extrusion force of Ramyon made from sample A(potassium carbonate 64%, sodium carbonate 14%, sodium pyrophosphate 2% and sodium metaphosphate 20%), sample B(potassium carbonate 31%, sodium carbonate 39% , sodium pyrophosphate 1%, sodium metaphosphate 15%, sodium polyphosphate 8%, sodium phosphate monobasic 4% and sodium phosphate dibasic 2%), sample C(potassium carbonate 60%, sodium carbonate 33% and sodium pyrophosphate 7%), and sample D(potassium carbonate 44%, sodium carbonate 27%, sodium metaphosphate 27% and sodium polyphosphate 2%) were 12.80(kgf), 10.35(kgf), 9.05(kgf) and 8.45(kgf), respectively, but that of control I was 5.24(kgf). The hardness of Ramyon manufactured with sample A, B, C and D were 18.57(kgf), 16.48(kgf), 14.26(kgf) and 12.34(kgf), respectively, but that of control I was 11.23(kgf). At cooking quality examination of Ramyon made from several alkali agents, weight of cooked Ramyon was increased but volume was appeared in vice versa. Extraction amounts of Ramyon manufactured with several alkali agents during cooking were from 35% to 38%, but that of control I was 70%. These changes will provided many advantages in the preparation of Ramyon. The $I_2$ reaction value(${\alpha}-degree$ of noodle) of Ramyon manufactured with several alkali agents and control were shown to almost same values, from 2.10 to 2.20. Sensory properties of cooked Ramyon which was manufactured with several alkali agents showed quite acceptable.

  • PDF

ERUPTION GUIDANCE OF IMPACTED MANDIBULAR FIRST MOLAR (매복된 하악 제1대구치의 맹출 유도)

  • Lee, Doo-Young;Song, Je-Seon;Lee, Jae-Ho;Choi, Byung-Jai;Kim, Seong-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.226-232
    • /
    • 2010
  • Incidence of tooth impaction varies from 5.6 to 18.8% of the population. Failure of eruption of the first and second permanent molars is rare; the prevalence in the normal population is 0.01% in case of the first permanent molar, and 0.06% in case of the second permanent molar. Permanent molars are particularly important for providing sufficient occlusal support and co-ordinating facial growth. Failure of eruption of permanent molars may result in various complications such as decrease in vertical dimension, posterior open bite, extrusion of antagonistic teeth, resorption and inclination of adjacent teeth, formation of cyst and so on. Treatment options of impacted teeth are periodic observation, surgical exposure, surgical exposure with subluxation, orthodontic relocation, and surgical extraction before prosthetic treatment. Early diagnosis and treatment are important, because delayed treatment induces various problems such as decreased spontaneous eruptive force, decreased successful percentage, increased treatment period, increased various complications. Prevalence of the failure of mandibular first molars is rare but eruptive guidance before extraction of impacted teeth is necessary due to importance of permanent molars. We reported two cases of surgical exposure of impacted mandibular first molar. In these cases, we could observe different result of the impacted mandibular first molar after surgical exposure.

Clinical evaluation of a new extraction method for intentional replantation (의도적 재식술을 위한 새로운 발치법의 임상 평가)

  • Choi, Yong-Hoon;Bae, Ji-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: Intentional replantation (IR) is a suitable treatment option when nonsurgical retreatment and periradicular surgery are unfeasible. For successful IR, fracture-free safe extraction is crucial step. Recently, a new extraction method of atraumatic safe extraction (ASE) for IR has been introduced. Patients and Methods: Ninety-six patients with the following conditions who underwent IR at the Department of Conservative Dentistry, Seoul National University Bundang Hospital, in 2010 were enrolled in this study: failed nonsurgical retreatment and periradicular surgery not recommended because of anatomical limitations or when rejected by the patient. Preoperative orthodontic extrusive force was applied for 2-3 weeks to increase mobility and periodontal ligament volume. A Physics Forceps was used for extraction and the success rate of ASE was assessed. Results: Ninety-six premolars and molars were treated by IR. The complete success rate (no crown and root fracture) was 93% (n = 89); the limited success rates because of partial root tip fracture and partial osteotomy were 2% (n = 2) and 5% (n = 5), respectively. The clinical and overall success rates of ASE were 95% and 100%, respectively; no failure was observed. Conclusions: ASE can be regarded as a reproducible, predictable method of extraction for IR.

ERUPTION GUIDANCE FOR TOOTH GERM OF PREMOLAR DISPLACED BY INFRAOCCLUDED UPPER DECIDUOUS MOLAR (저위교합된 상악 유구치에 의해 변위된 소구치 치배의 맹출유도)

  • Jung, Jung-Hwa;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.390-396
    • /
    • 2012
  • Infraocclusion is defined as tooth whose relative occlusal movement was blocked during the period of active eruption due to ankylosis and so on. Then infraoccluded tooth remains under the occlusal plane composed by adjacent structures showing normal eruption patterns. Untreated infraocclusion may cause: prolonged retention of infraoccluded teeth; extrusion of apposed teeth; destruction of periodontal tissues by occlusal force and food packing; increased sensitivity for dental caries; and disturbances on eruption pathway of succedaneous teeth. Therefore, periodic check-ups and proper treatments are required. There are many treatment options on infraoccluded deciduous molars such as periodic observation, conservative method, restoration and space regaining with extraction of the teeth. The choice of treatment may depend on the presence of succedaneous teeth, time of diagnosis and degree of infraocclusion. In this case report, three patients showing displacement of the second premolars due to infraocclusion of upper second primary molars, were treated by means of space regaining with removable orthodontic appliances and extraction of ankylosed primary molars. All malpositioned permanent premolars in the 3 cases showed ordinary eruption pathways after treatment.

Three-Dimensional Kinematic Model of the Human Knee Joint during Gait

  • Mun, Joung-Hwan;Seichi Takeuchi
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.171-179
    • /
    • 2002
  • It is well known that the geometry of the articular surface plays a major role in the kinematic and kinetic analysis to understand human knee joint function during motion. The functionality of the knee joint cannot be accurately modeled without considering the effects of sliding and lolling motions. We Present a 3-D human knee joint model considering sliding and rotting motion and major ligaments. We employ more realistic articular geometry using two cam profiles obtained from the extrusion of the sagittal Plain view of the representative Computerized Tomography image of the knee joint compared to the previously reported model. Our model shows good agreement with the already reported experimental results on Prediction of the lines of force through the human joint during gait. The contact point between femur and tibia moves toward the Posterior direction as the knee undergoes flexion, reflecting the coupling of anterior and Posterior motion with flexion/extension. The anterior/posterior displacement of the contact Point on the tibia plateau during one gait cycle is about 16 mm. for the lateral condyle and 25 mm. for the medial condyle using the employed model Also. the femur motion on the tibia undergoes lateral/medial movement about 7 mm. and 10 mm. during one gait cycle for the lateral condyle and medial condyle. respectively. The developed computational model maybe Potentially employed to identify the joint degeneration.

Evaluation of Fluidity Over Time and Mechanical Properties of Cement-based Composite Materials for 3D Printing (3D 프린팅용 시멘트계 복합재료의 경시변화 및 역학적 특성평가)

  • Seo, Eun-A;Lee, Ho-Jae;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.73-80
    • /
    • 2022
  • This study evaluated changes in fluidity and rheological properties over time for 3D printed composite materials, and evaluated compressive strength and splitting tensile strength properties for laminated and molded specimens. The composite material for 3D printing starts to change rapidly after 30 minutes of extrusion, and the viscosity of the material tends to be maintained up to 90 minutes, but it was confirmed that construction within 60 minutes after mixing is effective. The compressive strength of the laminated test specimen showed equivalent or better performance at all ages compared to the molded test specimen. In the stress-strain curve of the laminated specimen, the initial slope was similar to that of the molded specimen, but the descending slope was on average 1.9 times higher than that of the molded specimen, indicating relatively brittle behavior. The splitting tensile strength of the P-V laminated specimen was about 6% lower than that of the molded specimen. It is judged that this is because the interfacial adhesion force against the vertical load is affected by the pattern direction of the laminated test specimen.