• Title/Summary/Keyword: extinguishing

Search Result 464, Processing Time 0.031 seconds

Effects of Particle Size of Dry Water on Fire Extinguishing Performance (드라이워터의 입자크기가 소화성능에 미치는 영향)

  • Lee, Eungwoo;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.28-35
    • /
    • 2019
  • Dry water is a core-shell structured powder which comprises a very fine water core covered with hydrophobic silica particles. Recently, the dry water has attracted attention as a new type of fire extinguishing agents. However, characteristics of the dry water as a fire extinguishing agent have not been revealed until now. To our best knowledge, this is the first work to uncover effects of particle size of the dry water on the fire extinguishing performance. Pristine dry water, which has heterogeneous particle size distribution, was carefully separated by sieving method into three fractions which were a small size (ca. $110{\mu}m$) fraction, a medium size (ca. $220{\mu}m$) fraction and a large size (ca. $400{\mu}m$) fraction. Microscopic observations confirmed the effective separation of dry water's particle size. In extinguishing tests of wood cribs fire, the medium size dry water showed most excellent fire extinguishing performance, as compared to other dry waters having small (ca. $110{\mu}m$) and large (ca. $400{\mu}m$) particle size. The good performance of the medium size (ca. $220{\mu}m$) dry water may be attributed to the balance between cooling effect of the water core and smothering effect of the silica particles. It is also revealed that small size dry water has poor flowability than large size dry water.

Trends of Onboard Fire Extinguishing System (선박용 소화설비의 국제동향)

  • Kim, Mann-Eung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.126-127
    • /
    • 2005
  • This paper provides information on the current issues and the progress of on-going researches relating onboard fixed fire extinguishing system in the IMO Sub-committee on Fire Protection. And also prepares to introduce the recent amendment to regulations and technical trends of the water mist fire extinguishing system and high expansion foam system.

  • PDF

A Study on the Extinction Concentration of Inert Gas for Extinction Performance Estimation of Kerosene (등유의 소화성능 평가를 위한 불활성 가스의 소화농도에 관한 연구)

  • Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.34-38
    • /
    • 2007
  • The experiment was done to investigate extinguishing concentrations of different inert gases of verying concentrations made in contact with Kerosene. The experimental results obtained are as follows; at a standard amount of air flow was 40L/min, the extinguishing concentration of Argon, Nitrogen, Carbon dioxide and Helium for Kerosene were 36.5%, 27.3%, 17.4%, 12.3%, respectively. And, according to these results, Helium of 12.3% showed the lowest extinguishing concentration.

A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding (전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구)

  • Lee, Se-Myeoung;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.15-23
    • /
    • 2012
  • Indirect Test Method is often used instead of direct test method in test method for extinguishing performance of $CO_2$ extinguishing facility because of high cost, environment problems and difficulties of procedure. But in the danger facilities for a unit of nation, such as a petrochemical plant, a nuclear power plant, or etc. is better to verify the performance of the extinguishment through direct discharge test. In $CO_2$ extinguishing system for total flooding system installed in dangerous facilities in Korea, each protected area in surface fire and deep-seated fire had selected and verified of extinguishing performance of $CO_2$ extinguishing facilities. To get recognized as extinguishing performance, discharged $CO_2$ concentration to protected area should be equivalence with design concentration standards (NFSC and NFPA). The Design Concentration means that $CO_2$ extinguishing agent is considerate of concentration for percentage of allowance (20 %) from extinguishing concentration which available to control of flame. As test result, surface fire and deep seated fire in protected area is obtained $CO_2$ design concentration and maintained design concentration more than 20 minutes as deep-seated fire. Through this study, we introduced direct discharging test method and decision method. And furthermore, especially in the dangerous facilities as a unit of Nation, we suggested necessity about reliability of extinguishing facilities to use direct test method.

An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents (소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구)

  • Han, Yong-Taek;Kim, Dong-Ho;Kwon, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • Several complex devices and equipments are installed in the car's engine room, including various kind of oils or other flammable materials. So re-ignition is very likely to take place in it. In addition, it is restrictive for the driver or the occupant to open the bonnet and to spray the fire extinguisher in the engine room due to the high possibility of explosion. Therefore, a fire extinguishing system, which can detect a fire and inject the fire extinguishing agent to extinguish it, and fire extinguishing agents including HFC-227ea, which can stand the high temperature within the engine room and hold the viscosity sufficient to keep it in the kind of foam, were developed and tested. And the suffocation effect and the cooling effect come from the fire extinguishing principle of the foam fire extinguishing agent and the inhibiter catalyst effect come from the one of HFC-227ea was led simultaneously, and fire extinguishing agents without the secondary damage caused by residuals after the fire extinguishment like a case of the powder fire extinguishing agent, were developed. And experiments using a vehicle collision after the discharge is complete, foreign material can be removed without extinguishing the advantage that experimental results obtained.

Wetting Agent Performance Evaluation Using Scale Model (축소모형 실험을 통한 침윤소화약제 소화성능 평가)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.20-25
    • /
    • 2014
  • In this study, the extinguishing performance evaluation of wetting agent for wood crib was conducted by using a scale model equipment that we designed. To confirm the optimal conditions of the experiment, a test was changed amount of fire extinguishing water and the number of timber. As a result, the discrimination of the fire extinguishing performance was seen only when 20 pieces of wood and the extinguishing water of 100 mL were used. After evaluating the extinguishing performance of domestic and foreign wetting extinguishing agents under these conditions, a reignition was occurred in only when we used water. In addition, the discrimination of extinguishing performance was seen through the temperature distribution according to the time of watering. Based on the results of this experiment, this study is expected to be able to use as a basis on presenting a method of optimized performance evaluation of wetting extinguishing agent.

Characteristics of Fixed Aerosol Auto Fire-Extinguishing Systems (고체에어로졸 자동소화장치 특성)

  • Choi, Byoung-O;Hong, Chang-Su;Kwon, Seong-Won;Park, Sun-Gyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.277-282
    • /
    • 2008
  • We developed fixed aerosol auto fire-extinguishing systems which are different from fire suppression systems like powder extinguisher or halon extinguishing system, etc. Fixed aerosol auto fire-extinguishing substances which are including solid alkali salts generated by combustion of solid composition. It represents high fire suppression ability due to particle friendly auto fire-extinguishing systems for the reason of excluding toxic substances in it's composition.

  • PDF

A Study on Measuring of Fire Extinguishing Concentration for Organic Material Using Novec (노벡을 이용한 유기물의 소화농도 측정에 관한 연구)

  • Lim, Woo-Sub;SaKong, Seong-Ho;Jung, Jong-Jin;Nam, Dong-Gun;Choi, Kenu-Joo;An, Sang-Su;Kim, Jong-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.456-460
    • /
    • 2008
  • This study was on basic step to develop a good clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using Novec which is inert gas. In study used to Cup Burner Test its made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test. The finding is that a new clean agent, Novec has a very efficient extinguishing ability in a state of gas.

  • PDF

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.

A Study on the auto fire-extinguishing system in the subway train (지하철 전동차내 자동소화 시스템 연구)

  • Lee Tae-Shik;Moon Young-Hyun;Hong Hyo-Sik
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.168-173
    • /
    • 2004
  • This research shows the method about the auto extinguishing system construction for the subway train's safety operation. The safety system is the total auto extinguishing system which it is able to overcome the emergency situation, to see fast using the sensing system, to interface using the communication system, finally to extinguish the large-scale fire happened. The system model is the total disaster mitigation system model preventing the arson or terror. and to apply a method of the fire extinguishing system using reinforced fire extinguishing agency in the world first. It is to use the subway train and the railroad train which is prevented and mitigated the large-scale demage the same as the arson and the terror.

  • PDF