• 제목/요약/키워드: external rotation

검색결과 555건 처리시간 0.021초

옆구리 부위의 거대 연부조직 결손에 대한 역넓은등근 근육피부피판을 이용한 치험례 (Flank Reconstruction of Large Soft Tissue Defect with Reverse Pedicled Latissimus Dorsi Myocutaneous Flap: A Case Report)

  • 송승용;김다한;김정헌
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.894-898
    • /
    • 2011
  • Purpose: Coverage of full-thickness large flank defect is a challenging procedure for plastic surgeons. Some authors have reported external oblique turnover muscle flap with skin grafting, inferiorly based rectus abdominis musculocutaneous flap, and two independent pedicled perforator flaps for flank reconstruction. But these flaps can cover only certain portions of the flank and may not be helpful for larger or more lateral defects. We report a case of large flank defect after resection of extraskeletal Ewing's sarcoma which is successfully reconstructed with reverse latissimus dorsi myocutaneous flap. Methods: A 24-year-old male patient had $13.0{\times}7.0{\times}14.0$ cm sized Ewing's sarcoma on his right flank area. Department of chest surgery and general surgery operation team resected the mass with 5.0 cm safety margin. Tenth, eleventh and twelfth ribs, latissimus dorsi muscle, internal and external oblique muscles and peritoneum were partially resected. The peritoneal defect was repaired with double layer of Prolene mesh by general surgeons. $24{\times}25$ cm sized soft tissue defect was noted and the authors designed reverse latissimus dorsi myocutaneous flap with $21{\times}10$ cm sized skin island on right back area. To achieve sufficient arc of rotation, the cephalic border of the origin of latissimus dorsi muscle was divided, and during this procedure, ninth intercostal vessels were also divided. The thoracodorsal vessels were ligated for 15 minutes before divided to validate sufficient vascular supply of the flap by intercostal arteries. Results: Mild congestion was found on distal portion of the skin island on the next day of operation but improved in two days with conservative management. Stitches were removed in postoperative 3 weeks. The flap was totally viable. Conclusion: The authors reconstructed large soft tissue defect on right flank area successfully with reverse latissimus dorsi myocutaneous flap even though ninth intercostal vessel that partially nourishes the flap was divided. The reverse latissimus dorsi myocutaneous flap can be used for coverage of large soft tissue defects on flank area as well as lower back area.

이축압축 조건에서 실험체/재하판 경계면상의 마찰저항 감소를 위한 롤러 지지된 피스톤 형태의 하중재하판의 개발 (Development of a roller supported piston type loading platen reducing the frictional restraint along the interfaces between the specimen and platens under the biaxial loading condition)

  • 사공명;김세철;이준석;박두희
    • 한국터널지하공간학회 논문집
    • /
    • 제10권3호
    • /
    • pp.303-312
    • /
    • 2008
  • 암석의 물성평가 및 파괴모델 실험을 위하여 다축압축 실험이 자주 사용된다. 다축압축 실험을 통한 암반의 거동 평가시 정확한 결과의 산출을 위하여 실험체와 가압판 경계면에서의 경계조건에 대한주의를 기울일 필요가 있다. 일반적으로 철제로 된 일체형 가압판의 사용시 실험체의 경계면과 하중재하판사이에서 발생하는 마찰저항으로 인하여 실험체 경계부에서부터 응력회전 현상이 발생하여 경계면에서부터 작용하는 외력의 방향은 회전하게 된다. 이와 같은 실험체/하중재하판 경계면 사이에서 발생하는 마찰저항을 감소시키기 위하여 다양한 방법이 제시되었다. 그 중 대표적인 예가 빗살구조의 하중재하판이다. 본 논문에서는 빗살구조의 하중재하판의 단점을 극복하고 하중재하판의 공간이 상대적으로 덜 차지하는 롤러로 지지된 피스톤 형태의 하중재하판을 소개하고 있다. 롤러로 지지된 피스톤 형태의 하중재하판은 지지강성이 충분한 짧은 피스톤 후면에 샤프트 형태의 롤러를 설치하여 실험체의 변형과 동시에 각 피스톤이 동반하여 거동하도록 구성되었다. 본 논문에서는 롤러 지지된 피스톤의 구조 상세 및 요구되는 기능에 대한 검증을 위하여 측면부 마찰저항 실험과 이축압축 실험이 수행되었으며 실험결과와 수치해석 결과의 비교를 통하여 장비의 적용성에 대한 검증이 이루어 졌다.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 추계학술발표회 초록집
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

조적벽체의 형상비에 따른 접착형 보강재의 보강효과에 관한 실험적 연구 (An Experimental Study for Reinforcement Effect of Adhesive Stiffeners Depending on the Aspect Ratio of Masonry Wall)

  • 박병태;권기혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.13-20
    • /
    • 2017
  • 비보강 조적조 건축물은 재료의 특성상 지진과 같은 횡력에 취약하지만, 국내에는 여전히 많은 조적조 건물이 존재한다. 특히 현재 남아있는 조적조 건축물의 대부분이 20년 이상 노후화됨에 따라 재해감소를 위한 경제성 있는 보강법의 개발이 요구된다. 본 논문에서는 이러한 노후 된 조적조 건축물의 보강법의 하나로 접착형 보강재를 활용한 조적벽체의 외부 보강법을 제시하였으며, 보강효과 검증을 위해 총 6개의 실험체를 형상비(L/H=1.0, 1.3, 2.0)를 변수로 제작하여 정적가력실험을 실시하였다. 실험결과, 보강전 후 조적벽체는 강체회전 및 미끄러짐에 의해 파괴가 발생하였고, 접착형 보강재 부착후 벽체의 최대내력, 최대변위, 소산에너지량은 증가하여 우수한 보강효과를 확인하였다. 또한 기존 유리섬유를 활용한 증가된 전단강도식에 착안하여 비보강 조적벽체에 대한 접착형 보강재의 설계안을 도출하여 적용을 위한 기초자료를 제공하였다.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향 (Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws)

  • 신현모;조욱;정창모
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.53-59
    • /
    • 2009
  • 본 연구는 external butt joint 연결 형태를 가진 임플랜트 시스템에서 티타늄 합금 나사와 텅스텐 카바이드와 탄소로 코팅한 나사의 압축력 및 조임 회전각 측정을 통해 동일한 전하중을 얻는 데 있어 코팅나사 사용이 갖는 임상적 효율성을 간접적으로 비교해 보고자 하였다. 본 연구에서는 Osstem Implant의 US II 시스템 고정체(${\phi}=4mm$)와 Cemented abutment를 사용하여 티타늄 합금(Ta) 지대주 나사 및 텅스텐 카바이드와 탄소로 표면 처리한(WC/CTa) 지대주 나사에 30Ncm의 조임 회전력을 적용한 후 압축력 및 조임 회전각을 측정하였다. 다음 WC/CTa 지대주 나사에서 측정된 압축력의 평균값을 계산하고 이를 Ta 지대주 나사에 적용하여 동일한 압축력이 가해질 때의 조임 회전력 값을 측정하였다. 그리고 실험결과 측정된 조임 회전력의 평균값을 Ta 나사에 적용한 후 조임 회전각을 측정하여 비교해 본 결과 다음과 같은 결론을 얻었다. 30Ncm의 조임 회전력에서 텅스텐 카바이드/탄소 코팅 나사가 티타늄 합금 나사보다 압축력과 회전각이 더 높게 나타났다. 텅스텐 카바이드/탄소 코팅 나사에 30Ncm의 조임 회전력을 적용하여 발생한 압축력을 얻기 위해서는 티타늄 합금 나사의 경우 55.6Ncm의 조임 회전력이 필요하였으며, 회전각에는 두 나사 간에 차이가 없었다.

Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC

  • Kim, Young-Rok;Park, Eunseo;Oh, Hyungjik Jay;Park, Sang-Young;Lim, Hyung-Chul;Park, Chandeok
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.269-277
    • /
    • 2013
  • In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion $X_P$ and $Y_P$ are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.

유리 공장 피판술 후 외부 감시 피판의 유용성 (Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap)

  • 김백규;장학;민경원;홍준표;고경석
    • Archives of Plastic Surgery
    • /
    • 제34권4호
    • /
    • pp.432-435
    • /
    • 2007
  • Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.

외부 자력을 이용한 촉수 생명체 애니매트로닉스 시뮬레이션 (Simulating tentacle Creature with External Magnetism for Animatronics)

  • 김예영;김도희;김주란;오나현;최명걸
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제29권5호
    • /
    • pp.1-9
    • /
    • 2023
  • 애니매트로닉스 제어 기술은 공학, 의학, 예술 등 여러 학문 분야에서 흥미로운 주제이며 관련 연구가 활발히 진행되고 있다. 애니매트로닉스의 움직임을 제어하는 일반적인 방법은 몸체 내부에 장착된 전동 모터를 사용하는 것이다. 하지만 이러한 방식은 몸체 내부의 공간이 좁을 경우 적용하기 어렵다. 본 연구에서는 몸체가 가늘고 긴 촉수 생명체의 움직임을 제어하기 위해 몸체 내부에 기계 장치를 장착하는 대신 외부 자력을 이용하는 방법을 제안한다. 구체적으로 본 연구에서는 애니매 트로닉스의 관절체 몸체를 자성이 있는 금속 소재로 만들어 외부에 설치된 전자석의 인력에 영향을 받도록 하였다. 그리고 전자석의 세기를 PID 제어기로 제어하여 애니매트로닉스 몸체의 위치를 실시간으로 제어할 수 있도록 하였다. 또한 자석이 회전 운동을 하도록 하고 회전의 속도를 변화시켜 다양한 움직임을 연출할 수 있도록 하였다. 본 연구의 실험은 가상 환경에 구현하여 시뮬레이션을 통해 수행되었다. 사용자에 의한 실시간 제어의 결과뿐만 아니라 다양한 스타일의 애니메이션 생성 방법 및 결과를 제시하여 그 효용성을 증명하였다.

Influence of Anticipation on Landing Patterns during Side-Cutting Maneuver in Female Collegiate Soccer Players

  • Park, Eun-Jung;Lee, Jung-Ho;Ryue, Jae-Jin;Sohn, Ji-Hoon;Lee, Ki-Kwang
    • 한국운동역학회지
    • /
    • 제21권4호
    • /
    • pp.391-395
    • /
    • 2011
  • To investigate the anticipatory effect on landing patterns during side-cutting maneuver, thirteen healthy female elite college soccer players participated in this study. Three-dimensional knee kinematics, effective mass and correlation between both these were measured and analyzed using a motion analysis and force plates. Each testing session included anticipated tasks, $45^{\circ}$ side-cutting tasks (AC), followed by a set of unexpected side-cutting (UC) in a random order. Knee flexion/extension, valgus/varus and internal/external rotation angles and effect mass were compared by using paired t-test. Also, correlation analysis was performed to identify the relationship between knee angles and effective mass. Effective mass during UC was greater than that during AC. Effective mass and maximum knee flexion angle were positively correlated during AC and not during UC. Based on the relationship between effective mass and knee flexion angle in AC, shock absorption can be controlled by knee joint flexion in pre-predicted movement condition. However, effective mass can not be controlled by knee flexion in UC condition. The unexpected load affects were more irregular on the knee joint, which may be one of the injury mechanisms of anterior cruciate ligament (ACL) in female soccer players.

뇌졸중 환자의 견관절 통증과 운동 기능 및 삶의 만족도와의 관계 (The Shoulder Pain after Stroke and the relationship with Motor Function, and Quality of Life)

  • 이동진;안승헌
    • 대한물리의학회지
    • /
    • 제6권3호
    • /
    • pp.257-266
    • /
    • 2011
  • Purpose : To assess the relationship between post-stroke shoulder pain, motor function, and pain-related quality of life(QOL) Methods : Volunteer sample of 62 chronic stroke survivors with post-stroke shoulder pain and glenohumeral subluxation. The patients answered the question in shoulder pain with the Brief Pain Inventory question 12 (BP1-12), Pain-related Quality of life(BPI-23). Therapists measured the performance of combined upper-limb movement including the hand-behind-neck(HBN), hand-behind-beck(HBB) maneuver, added passive pain-free shoulder external rotation range of motion, and Modified Ashworth Scale(MAS) score of the elbow flexors. Physical performance assessments were used to measure basic activity daily living(Modified Barthel Index-self care, MBI-S/C), motor function of upper limb(Fugl-Meyer Upper/Lower Extremity, FM-U/E). Results : Stepwise regression analyses indicated that post-stroke shoulder pain is associated with the BPI 23, but not with the FM-U/E, MBI-S/C. Thus, the presence of shoulder pain is more important predicting pain-related QOL than its degree in predicting motor function of upper limb and basic activity daily living. Conclusion : Post-stroke shoulder pain was associated with reduced quality of life related to pain. The pain was not associated with the motor function of upper limb and basic activity daily living. The result imply that management of shoulder pain & anatomical position of shoulder joint after stroke should be emphasized. This provides a further incentive to develop effective rehabilitation prevention and treatment strategies for post-stroke shoulder pain.