• 제목/요약/키워드: external rotation

검색결과 554건 처리시간 0.03초

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

노인의 고관절 ROM에 관한 연구 (A Study on Hip Joint ROM of the Elderly)

  • 엄기매;양윤권;장수경
    • 대한물리치료과학회지
    • /
    • 제9권2호
    • /
    • pp.67-75
    • /
    • 2002
  • The purpose of this study is to know the average of hip joint range of motion and difference according to the aging for the elderly. This study consisted of elder male(n=75) and elder female(n=109). The result of assessment and analysis in hip pint range of motion are as follows : 1) The average hip flexion(knee flexed) joint range of motion in 60-69(from sixty to sixty-nine)years old are $104.26^{\circ}$(Left-Male), $101.00^{\circ}$(Right-Male), $107.05^{\circ}$(Left-Female), $107.05^{\circ}$(Right-Female). 70-79years old are $104.59^{\circ}$(L-M), $102.05^{\circ}$(R-M), $105.73^{\circ}$(L-F), $108.75^{\circ}$(R-F). 80-89years old are $101.53^{\circ}$(L-M), $101.13^{\circ}$(R-M), $96.83^{\circ}$(L-F), $97.67^{\circ}$(R-F). There was significant difference in hip flexion(knee flexed) among female group(p<.01). The average hip flexion(knee extended) joint range of motion in 60-69(from sixty to sixty-nine)years old are $73.13^{\circ}$(Left-Male), $72.04^{\circ}$(Right-Male), $77.29^{\circ}$(Left-Female), $75.97^{\circ}$(Right-Female). 70-79years old are $74.95^{\circ}$(L-M), $72.19^{\circ}$(R-M), $76.73^{\circ}$(L-F), $76.65^{\circ}$(R-F). 80-89years old are $70.83^{\circ}$(L-M), $70.37^{\circ}$(R-M), $69.00^{\circ}$(L-F), $69.00^{\circ}$(R-F). There was significant difference in left hip flexion(knee extended) among female group(p<.05). 2) The average hip extension joint range of motion in 60-69years old are $13.09^{\circ}$(L-M), $12.78^{\circ}$(R-M), $10.97^{\circ}$(L-F), $10.68^{\circ}$(R-F). 70-79years old are $8.95^{\circ}$(L-M), $8.48^{\circ}$(R-M), $11.24^{\circ}$(L-F), $10.90^{\circ}$(R-F). 80-89 years old are $8.40^{\circ}$(L-M), $8.23^{\circ}$(R-M), $7.33^{\circ}$(L-F), $7.33^{\circ}$(R-F). There was significant difference in left(p<.01) and right(p<.05) hip extension among male group(p<.05). 3) The average hip abduction joint range of motion in 60-69 years old are $33.04^{\circ}$(L-M), $33.17^{\circ}$(R-M), $33.16^{\circ}$(L-F), $33.37^{\circ}$(R-F). 70-79 years old are $31.00^{\circ}$(L-M), $30.05^{\circ}$(R-M), $32.44^{\circ}$(L-F), $32.68^{\circ}$(R-F). 80-89 years old are $29.07^{\circ}$(L-M), $27.90^{\circ}$(R-M), $28.17^{\circ}$(L-F), $28.67^{\circ}$(R-F). There was no significant difference among group. 4) The average hip adduction pint range, of motion in 60-69years old are $29.57^{\circ}$(L-M), $29.35^{\circ}$(R-M), $31.87^{\circ}$(L-F), $31.89^{\circ}$(R-F). 70-79, years old are $27.41^{\circ}$(L-M), 27.00(R-M) $30.85^{\circ}$(L-F), $31.28^{\circ}$(R-F). 80-89 years old are $26.87^{\circ}$(L-M), $26.63^{\circ}$(R-M), $24.67^{\circ}$(L-F), $24.83^{\circ}$(R-F). There was significant difference in hip abduction among female group(p<01). 5) The average hip external rotation pint range of motion in 60-69years old are $32.26^{\circ}$(L-M), $31.17^{\circ}$(R-M), $33.53^{\circ}$(L-F), $34.42^{\circ}$(R-F). 70-79 years old are $31.64^{\circ}$(L-M), $28.62^{\circ}$(R-M) $31.29^{\circ}$(L-F), $31.45^{\circ}$(R-F). 80-89 years old are $26.40^{\circ}$(L-M), $26.07^{\circ}$(R-M), $24.77^{\circ}$(L-F), $24.27^{\circ}$(R-F). There was significant difference in left(male, female p<.01) and right(female p<.0l) hip external rotation among group. 6) The average hip internal rotation joint range of motion in 60-69years old are $30.30^{\circ}$(L-M), $28.13^{\circ}$(R-M), $34.27^{\circ}$(L-F), $36.03^{\circ}$(R-F). 70-79years old are $31.24^{\circ}$(L-M), $29.57^{\circ}$(R-M), $28.51^{\circ}$(L-F), $29.10^{\circ}$(R-F). 80-89 years old are $24.63^{\circ}$(L-M), $24.40^{\circ}$(R-M), $24.27^{\circ}$(L-F), $24.27^{\circ}$(R-F). There was significant difference in left(male p<.05, female p<.01) and right(female p<.01) hip internal rotation among group.

  • PDF

소아마비에서 4절 연쇄 장하지보조기 사례연구 (Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis)

  • 김장환;권오윤;이충휘;조상현;신헌석;최흥식
    • 한국전문물리치료학회지
    • /
    • 제20권1호
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료 (The Treatment of Humerus Shaft Simple Fracture by MIPO Technique)

  • 고상훈;이선호;조범근
    • Clinics in Shoulder and Elbow
    • /
    • 제16권1호
    • /
    • pp.27-32
    • /
    • 2013
  • 목적: 상완골 간부 단순 골절의 수술적 치료에서 잠김 압박 금속판을 이용한 최소 침습적 금속판 골유합술의 임상적 및 방사선학적 결과를 분석하였다. 대상 및 방법: 2010년 8월부터 2011년 5월까지 상완골 간부 단순 골절 골절에 대해 최소 침습적 금속판 골 유합술을 통해 수술을 시행하고 전향적으로 12개월 이상 추시한 6례의 환자를 대상으로 하였으며, 임상적 및 방사선학적 골유합 기간 및 술 후 관절 운동 범위와 기능을 확인하였다. 결과: 임상적 및 방사선학적 평균 골유합 기간은 각각 7.2주, 8주였다. 술 후 골 정렬에서 전후상 평균 2.8도, 측면상 내반 2도의 변형을 보였다. 술 후 12개월째 견관절 운동 범위는 전방거상 167도, 외회전 50도, 내회전 수위는 흉추 11번이었고, 평균 VAS는 1.2점, KSS는 91.3점, ASES는 26.5점, UCLA 점수는 31.5점이었다. 결론: 상완골 간부 단순 골절의 수술적 치료에서 최소 침습적 금속판 골유합술은 방사선학적 및 기능적으로 우수한 결과를 보였으며 상완골 간부 단순 골절에서 고려해 볼 수 있는 유용한 치료 방법 중 하나라고 생각된다.

Short-term of Reverse Total Shoulder Arthroplasty for the Treatment of Irreparable Massive Rotator Cuff Tear

  • Park, Jong-Hyuk;Wang, Seong-Il;Lee, Byung-Chang
    • Clinics in Shoulder and Elbow
    • /
    • 제17권4호
    • /
    • pp.152-158
    • /
    • 2014
  • Background: To investigate the effectiveness of reverse total shoulder arthroplasty (RTSA) in treating irreparable massive rotator cuff tears (RCTs). Methods: Twenty-nine patients who underwent RTSA for the treatment of irreparable massive RCTs and completed follow-up for at least 1 year were selected. Their mean age was 69.7 years (range, 59-80 years). The mean follow-up was 17.7 months (range, 12-42 months). The shoulder range of motion was measured preoperatively and at final follow-up. The functional result was evaluated using visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeon (ASES) score, and Korean Shoulder Society (KSS) score. Additionally, the shoulders were categorized into two groups depending on prior history of surgery and the clinical outcomes were analyzed between two groups. Results: Mean pain VAS improved, from $6.6{\pm}1.2$ to $2.7{\pm}0.9$ (p=0.001), and the mean functional VAS from $35.7{\pm}4.2$ to $73.3{\pm}5.4$ (p=0.006). The mean ASES score improved from $37.2{\pm}2.8$ to $75.0{\pm}3.8$ (p=0.012). The mean KSS improved from $36.5{\pm}7.2$ to $75.6{\pm}5.4$ (p=0.009), the mean forward elevation from $66.3{\pm}4.7$ to $135.6{\pm}8.4$ (p=0.0001), and the mean abduction from $45.2{\pm}4.2$ to $119.0{\pm}6.5o$ (p=0.0001). Internal rotation differed significantly from the first sacral to the third lumbar vertebrae (p=0.036). External rotation did not change significantly (p=0.076). There was also no statistically significant difference between groups (no previous operation versus none). Four complications occurred: one superficial infection, one with anterior dislocation, one acromial fracture, and one clavicle fracture. Conclusions: RTSA provides reliable pain relief and recovery of shoulder function in patients with massive irreparable RCTs in short-term follow-up.

폴라루스 골수정을 이용한 상완골 근위부 골절의 치료 (Treatment of Proximal Humerus Fracture by Polarus Nailing)

  • 최창혁;권굉우;정대의;장호진
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.169-175
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the usefullness of polarus nailing in the treatment of proximal humerus fractures including 2 part, 3 part and proximal comminuted fractures. Materials and methods: Fifteen cases of proximal humerus fracture treated with Polarus nailing from March, 2002 to March, 2004 were selected. Man was 3 cases, and woman was 11 cases. There were one case of follow up loss due to decease. Average age was 60 years old (range, 23 to 84), and there were 6 cases of 2 part fracture, 3 cases of proximal segmental fracture, 5 cases of 3 part fracture. We analyzed the outcom results between 2 part fracture and 3 part fracture. The average follow up period after the operation was 1.5(range, 1 to 2) years. Range of motion (ROM), pain and functional outcome were evaluated by visual analogue scale(VAS) and american shoulder and elbow surgery (ASES) activity of daily living (ADL) functional scoring system. Results: All cases showed union on radiologic evaluation, with 2.3 months follow up. In 5 cases of 3 part fracture, average union time was 1.9 months regardless of proximal screw loosening in 4 cases. In 2 part fracture union time was 2.2 months (P>0.05). VAS pain score was 1.3, ROM was $160^{\circ}$ in forward flexion, $40^{\circ}$ in external rotation, L3 level in internal rotation, and ASES, ADL functional score was 21 in 2 part fracture. VAS pain score was 1.25, ROM was $160^{\circ}$, $43^{\circ}$ and L1 level, and ASES, ADL functional score was 21 in 3 part fracture. There were no statistically significant difference between two groups (P>0.05) VAS pain score was 1.6, ROM was $170^{\circ}$, $47^{\circ}$ and L3 level, and ASES, ADL functional score was 23 in proximal comminuted fracture. Conclusion: Polarus nailing could be used as an effective modality in certain cases of proximal humeral fracture including 2 part, proximal segmental and in cases of 3 part fractures with large greater tuberosity fragment.

견봉쇄골 관절의 급성 탈구에서 원추인대 기능의 강화를 위한 봉합 나사못을 추가한 변형된 Phemister 술식 (The Modified Phemister Operation with the Suture Anchor Added for the Augmentation of Conoid Ligament in Acute Acromioclavicular Dislocation)

  • 문기혁;남일현;이영현;김기철;이재훈;안길영
    • Clinics in Shoulder and Elbow
    • /
    • 제13권1호
    • /
    • pp.34-39
    • /
    • 2010
  • 목적: 견봉쇄골 관절의 급성 탈구에서 원추인대 기능의 강화를 위한 봉합 나사못을 추가한 변형된 Phemister 술식의 치료 방법을 소개하고 그 결과를 알아보고자 하였다. 대상 및 방법: 14예의 환자를 대상으로 하였으며 Rockwood 제 3형이 11예, 5형이 3예 였고 환자의 평균나이는 45.2세 였다. 변형된 Phemister 술식에 원추인대 기능의 강화를 위한 봉합 나사못을 추가하여 수술하였다. 추시 기간은 평균 14개월이었으며 술 후 임상적 평가는 Weitzman 분류 및 VAS 점수와 Constant 점수, KSS 점수를 사용하였다. 결과: Weitzman 분류상 13예에서 우수, 1예에서 양호로 평가되었고 평균 관절 운동 범위는 전방거상 170.7도, 외전 166.4도, 외회전 68.2도, 내회전 T7 였다. 평균 VAS 점수는 1.9, 평균 Constant 점수는 90.8점, 평균 KSS 점수는 91점이었다. 방사선학적 평가 결과는 모든 예에서 양호한 결과를 얻었다. 결론: 견봉쇄골 관절의 급성 탈구에서 원추인대 기능의 강화를 위한 봉합 나사못을 추가한 변형된 Phemister 술식은 임상적으로 유용한 수술 방법으로 사료된다.

그립 유형에 따른 탄력밴드 저항운동 효과의 비교 연구 ; 유방절제술로 발생한 팔 림프부종 환자에 대한 통증 및 어깨관절가동범위에 대하여 (A Comparative Study of the Effect of Resisted Exercise Using Thera-bands according to Grip Type: Pain and Range of Motion of the Shoulder in a Patient with Lymphedema after Mastectomy)

  • 조예진;이상열
    • 대한통합의학회지
    • /
    • 제8권1호
    • /
    • pp.47-56
    • /
    • 2020
  • Purpose : The purpose of this study was to determine the effects of upper extremity volume, pain, and range of motion after participation in thera-band exercises according to the hand grip type in patients with breast cancer with upper extremity edema. We also aimed to determine the most efficient type of grip. Methods : The subjects were 10 female patients diagnosed with stage 2 breast cancer who had stage 2 lymphedema. Randomly, 5 patients each were allocated to the experimental and control groups. For six weeks, the patients in both the experimental and control groups exercised daily. In both groups, manual lymph drainage was applied for 1 hour. Afterward, patients in the experimental group placed their hands in the thera-band ring and exercised with their fingers outstretched. Patients in the control group exercised while holding the thera-band ring with a finger. Both the experimental group and the control group underwent measurements of the circumference of the upper extremity, pain, and range of motion of the shoulder joint at weeks 1, 2, 4, and 6 before and after exercise. Results : The upper arm circumference decreased by more in the experimental group in all weeks than before than that in the control group, and there was a statistically significant difference at 6 weeks. Compared with the difference between pre-exercise and 6 weeks post-exercise, the change in pain significantly decreased in the experimental group and showed a statistically significant difference. The shoulder range of motion increased in extension, external rotation, and internal rotation compared with that in the control group, and there was a statistically significant difference. Although the operating range increased in flexion and abduction, there were no statistically significant differences. Conclusion : In this study, we found that thera-band exercises with an open-hand grip are more efficient than thera-band exercises with a closed-hand grip in edema reduction, pain, and range of motion. In addition, it was found that it was more effective to continue the thera-band exercises with open-hand grip extended for at least 6 weeks rather than for a short time.

In vivo 3-dimensional Kinematics of Cubitus Valgus after Non-united Lateral Humeral Condyle Fracture

  • Kim, Eugene;Park, Se-Jin;Lee, Ho-Seok;Park, Jai-Hyung;Park, Jong Kuen;Ha, Sang Hoon;Murase, Tsuyoshi;Sugamoto, Kazuomi
    • Clinics in Shoulder and Elbow
    • /
    • 제21권3호
    • /
    • pp.151-157
    • /
    • 2018
  • Background: Nonunion of lateral humeral condyle fracture causes cubitus valgus deformity. Although corrective osteotomy or osteosynthesis can be considered, there are controversies regarding its treatment. To evaluate elbow joint biomechanics in non-united lateral humeral condyle fractures, we analyzed the motion of elbow joint and pseudo-joint via in vivo three-dimensional (3D) kinematics, using 3D images obtained by computed tomography (CT) scan. Methods: Eight non-united lateral humeral condyle fractures with cubitus valgus and 8 normal elbows were evaluated in this study. CT scan was performed at 3 different elbow positions (full flexion, $90^{\circ}$ flexion and full extension). With bone surface model, 3D elbow motion was reconstructed. We calculated the axis of rotation in both the normal and non-united joints, as well as the rotational movement of the ulno-humeral joint and pseudo-joint of non-united lateral condyle in 3D space from full extension to full flexion. Results: Ulno-humeral joint moved to the varus on the coronal plane during flexion, $25.45^{\circ}$ in the non-united cubitus valgus group and $-2.03^{\circ}$ in normal group, with statistically significant difference. Moreover, it moved to rotate externally on the axial plane $-26.75^{\circ}$ in the non-united cubitus valgus group and $-3.09^{\circ}$ in the normal group, with statistical significance. Movement of the pseudo-joint of fragment of lateral condyle showed irregular pattern. Conclusions: The non-united cubitus valgus group moved to the varus with external rotation during elbow flexion. The pseudo-joint showed a diverse and irregular motion. In vivo 3D motion analysis for the non-united cubitus valgus could be helpful to evaluate its kinematics.

스테레오 카메라 기반 트윈 카메라 모듈 시스템 설계 및 구현 (Design and Implementation Stereo Camera based Twin Camera Module System)

  • 김태연
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.537-546
    • /
    • 2019
  • 본 논문에서는 휴대하기 편하고 3D 콘텐츠 제작이 용이한 트윈 카메라 모듈 시스템을 구현하고자 하였다. 제안한 트윈 카메라 모듈 시스템은 2D 스테레오 카메라로 부터 입력되는 영상을 변환하여 3차원 영상으로 출력할 수 있는 시스템이다. 본 눈문에서 제안한 시스템의 성능평가를 위해 Test Platform을 이용하여 좌, 우 두 개의 렌즈로 촬영된 스테레오 입체 영상의 좌, 우 영상 간의 시차에 따른 회전(Rotation), 기울기(Tilt)에 대한 보정을 평가하였다. 또한 SIFT(Scale Invariant Feature Transform) 알고리즘을 이용하여 3D 입체 영상의 거리오차(Depth Error)를 검증하여 트윈 카메라 모듈 시스템의 효율성을 검증하고자 하였다. 본 논문에서 제안한 트윈 카메라 모듈 시스템은 촬영된 영상을 3D 입체 영상과 준비 영상으로 변화하여 외부에 출력하면 각기 다른 3D 입체 영상 제작 방식에 따른 출력장치에 맞춰 디스플레이가 가능하다. 또한 생성된 영상을 준비 영상과 입체 영상을 각기 다른 채널을 통해 출력하여 많은 제품에 적용하기 쉽고 간편하게 3D 입체 영상 콘텐츠를 제작하는데 이용할 수 있을 거라 기대한다.