Ravi, Surekh;Chandy, Lazar J;Kumar, Gautam;Jacob, Biju;Emmanuel, Ami M
Clinics in Shoulder and Elbow
/
제24권1호
/
pp.32-35
/
2021
Angioleiomyoma is a benign soft tissue tumor originating from vascular smooth muscle. We report a case of a 20-year-old student who presented with pain in the right shoulder of 4 years duration. Shoulder movements were pain-free throughout the range of motion except resisted external rotation. Magnetic resonance imaging visualized a well-circumscribed lesion over the infraspinatus tendon. The lesion was surgically removed and sent for histopathological analysis. Morphology and immunohistochemistry results were suggestive of angioleiomyoma. The most common location for such a lesion is the lower limb, with less than 1% being reported in the upper arm, of which an angioleiomyoma of the shoulder is extremely rare.
This paper examines the dynamic response of rotating nanodevices under the external harmonic load. The spinning nanosystem is made of nanoscale tubes that rotate around the central nanomotor and is mathematically modeled via high-order beam theory as well as nonclassical nonlocal theory for the size impact. According to the Hamilton principle, the dynamic motion equations are derived, then the time-dependent results are obtained using the Newmark Beta technique along with the generalized differential quadratic method. The presented results are discussed dynamic deflection, resonant frequency, and natural frequency in response to the different applicable parameters, which help develop and produce nanoelectromechanical systems (NEMS) for various applications.
Anterior glenohumeral instability with an irreparable subscapularis tear is a challenging problem for the orthopedic shoulder surgeon. Current techniques, including tendon transfers, yield inconsistent results with high rates of recurrent instability. Acellular dermal allografting has been used in young patients with massive superior rotator cuff tears with early success, but acellular dermal allografting is comparatively unstudied in anterior deficiency. We present two cases of anterior capsular reconstruction with an acellular dermal allograft in patients ages 66 and 58 years with irreparable subscapularis tendon tears. Follow-up for both patients exceeded 4 years, with forward flexion >140°, external rotation exceeding 60°, a Single Assessment Numeric Evaluation score >90 points, a visual analog scale score of 0 points, and an American Shoulder and Elbow Score of 98 points. In conclusion, acellular dermal allografting can be used to reconstruct the anterior capsule in patients with massive irreparable subscapularis tears, similar to its use in superior capsular reconstruction in patients with massive posterosuperior rotator cuff tears.
The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.
목적: 회전근 개 파열과 동반된 견봉 쇄골 관절 병변에 대해 비수술적 치료를 시행한 후 견봉 쇄골 관절 병변이 동반되지 않은 환자들과 비교함으로써 원위 쇄골 절제술의 필요성에 대해 알아 보고자 하였다. 대상 및 방법: 2005년 1월부터 2011년 6월까지 본원에서 회전근 개 봉합술을 시행받고 최소 9개월 이상 추시 관찰이 가능하였던 45예를 대상으로 연구하였다. 이학적 검사상 견봉 쇄골 관절의 압통이 있고 자기공명영상 검사상 병변이 있는 환자를 견봉쇄골 관절 병변이 동반된 군으로 분류하였으며, 그렇지 않은 환자를 병변이 동반되지 않는 군으로 분류 하였다. 두 비교군 환자의 시간적 추이에 따른 견관절 근육의 외전, 내회전 및 외회전 근력 측정 및 ASES, KSS score 를 조사하여 비교 분석하였다. 결과: 견봉쇄골 관절의 병변이 있는 군에서의 근력 측정 결과 술 전 외전 8.05 (${\pm}4.54$), 내회전 11.33 (${\pm}6.06$), 외회전 10.24 (${\pm}5.27$)에서 술 후 외전 13.26 (${\pm}5.50$), 내회전 17.51 (${\pm}6.80$), 외회전 15.60 (${\pm}5.37$)로 향상된 결과 보였으며 KSS score 는 술 전 49.07 (${\pm}15.28$)점에서 술 후 84.48 (${\pm}10.97$)점, ASES score는 술 전 48.65 (${\pm}13.27$)점에서 술 후 84.65 (${\pm}9.86$)점으로 호전된 결과를 보였다. 견봉 쇄골 관절의 병변이 없는 군의 근력 측정 결과 술 전 외전 6.42 (${\pm}3.11$), 내회전 7.59 (${\pm}4.81$), 외회전 7.93 (${\pm}4.49$)에서 술 후 외전 15.85 (${\pm}7.35$), 내회전 19.18 (${\pm}9.14$), 외회전 16.95 (${\pm}5.70$)로 향상된 결과 보였으며 KSS score는 술 전 42.12 (${\pm}6.43$)점에서 술 후 83.44 (${\pm}6.29$)점, ASES score 는 술 전 41.37 (${\pm}7.42$)점에서 술 후 83.17 (${\pm}7.01$)점으로 두 군 모두 호전된 결과를 보였으나, 견봉 쇄골 관절의 병변이 있는 군에 비해 근력 측정값의 변화 및 ASES, KSS score 수치는 통계학적으로 유의한 차이를 보이지 않았다 (p>0.05). 결론: 회전근 개 파열과 동반된 견봉 쇄골 관절 병변이 있는 군과 없는 군에서 비수술적 치료를 시행한 후 비교 분석한 결과 두 군 모두 술 전에 비해서 술 후 근력 및 ASES, KSS score는 호전된 결과를 나타냈으며, 수술적 치료 후 평가 결과 두 군간에 유의한 차이가 없음을 알 수 있었다. 따라서 수술 전 회전근 개 파열에 동반된 견봉 쇄골 관절 병변에 대한 치료로서 원위 쇄골 절제술 선택도 가능하지만 보존적인 치료도 충분히 고려해야 될 것으로 생각된다.
목적: 이 논문의 목적은 후방 십자 인대와 함께 후 외방 구조물을 동반 재건한 경우의 결과를 분석하여 보고하고자 함이다. 대상 및 방법: 동종 아킬레스건을 이용하여 후방 십자인대 및 후 외방 구조물을 동반 재건하였던 10예를 대상으로 하였으며 평균 추시 기간은 25개월 이였다. 각각의 경우에서 수술 전 후방 불안정성의 정도를 측정하기 위해 KT-2000 관절계, 후방 전위 검사을 실시하였으며 후 외방 구조물 동반 손상에 의한 회전 불안정성을 진단하기 위해 경골 외회전 검사를 실시하였다. 환자의 주관적 평가는 Tegner, Lysholm score를 측정하여 최종 추시 시의 측정치와 비교하였다. 결과: 수술 전 KT-2000 측정치는 평균 7.1mm, 후방 전위 검사는 모든 예에서 Grade 3이였으며 경골 외 회전 검사상 슬관절 30도 및 90 도 굴곡 상태에서 모두 양성 반응을 보였다. Lysholm score는 평균 65.9. Tegner score는 평균 3.1이였다. 최종 추시 시 KT-2000 측정치는 평균 2.2 mm, 후방 전위 검사상 Grade 0이 2예, Grade 1이 4예, Grade 2가 3예, Grade 3가 1예였으며 경골 외회전 검사상 슬관절 30도 및 90 도 굴곡 상태에서 모두 양성으로 측정되었던 예는 1예였으며 90도에서만 양성으로 측정되었던 예는 2예였다. Lysholm score는 평균 87.6, Tegner score는 평균 5.7로 수술 전에 비해 주관적 객관적 평가 모두에서 호전되었다. 결론: 동종 아킬레스건을 이용한 관절경하 후방 십자 인대 및 후 외방 구조물은 재건은 후방 및 후 외방 회전 불안정성이 있는 환자에서 좋은 수술적 치료 방법중의 하나로 생각된다.
목적: 관절와 골 결손을 동반한 견관절 전방 불안정증에 대해 시행한 Latarjet 술식의 임상적 결과를 분석하고자 하였다. 대상 및 방법: 2006년 10월부터 2007년 5월까지 관절와의 현저한 골 결손을 동반한 재발성 전방 불안정증으로 Latarjet 술식을 시행 받은 14예를 대상으로 하였다. 추시 기간은 평균 15개월 (12~19개월), 평균 연령은 29.9세 (19~44세)였고, 남자가 13예였다. 우측이 8예, 좌측이 6예였으며, 우세수가 8예, 비우세수가 6예였다. 6예는 이전에 관절경적 뱅카르트 봉합술을 받은 후 재발하여 Latarjet 술식을 시행한 경우였다. 2예는 간질로 치료받는 환자였다. 결과: Rowe 점수는 수술 전 평균 51.8점에서 수술 후 평균 80.2점으로 향상되었고, 최우수 9예, 우수 4예, 양호 1예였다. Korean shoulder score for instability도 수술 전 평균 61.6점에서 수술 후 평균 82.1점으로 향상되었다. 능동적 전방 거상과 중립위 외회전 운동 범위는 수술후 건측과 비교하여 각각 8도와 16도 감소되었다. 전방 거상력과 중립위 외회전력은 수술 후 건측의 근력에 대해 각각 78.7%와 82.5%였다. 1예에서 간질 발작으로 재탈구가 발생하였고, 1예에서 일시적으로 한차례 아탈구가 있었다. 섬유성 골 유합이 2예, 전이된 오구 돌기의 흡수가 1예, 수술 중 나사에 의한 골 파괴가 1예, 수술 후 일시적 근피 신경 손상이 1예, 수술 후 견관절 강직이 1예 있었다. 결론: Latarjet 술식은 현저한 전방 관절와 골 결손을 동반한 견관절 전방 불안정증에서 수술 후 외회전 운동 범위의 감소를 유발할 수 있으나 관절 호의 길이를 연장시켜 견관절의 기능과 안정을 회복하는데 효과적인 방법이다. 오구 돌기 전이와 관련된 합병증이 많이 발생할 수 있어 이에 대한 주의가 요한다.
Jo, Na Young;Yeo, In Ho;Jung, Se Ho;Sung, Hee Jin;Lee, Cham Geol;Lee, Eun Yong;Roh, Jeong Du
Journal of Acupuncture Research
/
제31권2호
/
pp.111-118
/
2014
Objectives : Through an analysis of the previous studies, It is estimated that Chuna(shoulder traction) is effective in reducing the pain and increasing motion range of shoulder joint of the patient. So this study is to investigate the effects of Chuna(shoulder traction) on frozen shoulder. Methods : After treated with acupuncture and electro stimulating therapy, the subjects were measured list of measurement. And then treated with Chuna(shoulder traction) therapy, the subjects were measured list of measurement again. All treatment was performed by the same doctor who is a highly qualified about Chuna(shoulder traction). Chuna(shoulder traction) treatment takes 15 minutes. Three kind of Chuna(shoulder traction) therapy were performed for 5 minutes each. Depending on the degree of the subject's pain, treatment strength was adjusted. Results : - Chuna simultaneous treatment group, shoulder joint range of flexion, extension, abduction, adduction, external rotation and internal rotation movement improved statistically significant. - Chuna simultaneous and acupuncture treatment group, visual analogue scale(VAS) scores of two groups decreased statistically significant. Conclusions : The result suggests that Chuna(shoulder traction) can be effective to recover range of motion and reduce pain on patients with frozen shoulder.
Objective: The aim of this study was to examine the effect of foot landing type (forefoot vs. rearfoot landing) on kinematics, kinetics, and energy absorption of hip, knee, and ankle joints. Method: Twenty-five healthy men performed single-leg landings with two different foot landing types: forefoot and rearfoot landing. A motion-capture system equipped with eight infrared cameras and a synchronized force plate embedded in the floor was used. Three-dimensional kinematic and kinetic parameters were compared using paired two-tailed Student's t-tests at a significance level of .05. Results: On initial contact, a greater knee flexion angle was shown during rearfoot landing (p < .001), but the lower knee flexion angle was found at peak vertical ground reaction force (GRF) (p < .001). On initial contact, ankles showed plantarflexion, inversion, and external rotation during forefoot landing, while dorsiflexion, eversion, and internal rotation were shown during rearfoot landing (p < .001, all). At peak vertical GRF, the knee extension moment and ankle plantarflexion moment were lower in rearfoot landing than in forefoot landing (p = .003 and p < .001, respectively). From initial contact to peak vertical GRF, the negative work of the hip, knee, and ankle joint was significantly reduced during rearfoot landing (p < .001, all). The contribution to the total work of the ankle joint was the greatest during forefoot landing, whereas the contribution to the total work of the hip joint was the greatest during rearfoot landing. Conclusion: These results suggest that the energy absorption strategy was changed during rearfoot landing compared with forefoot landing according to lower-extremity joint kinematics and kinetics.
The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.