• Title/Summary/Keyword: external applications

Search Result 671, Processing Time 0.026 seconds

Verification of the Effectiveness of High Plank Exercise using Weightless Exercise Equipment (무중력 운동기구를 활용한 하이플랭크 운동의 효과성 검증)

  • You-Sin Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.342-347
    • /
    • 2023
  • The purpose of this study was to determine the comparison of upper arm, trunk and core muscle activities according to different performance in high Plank exercise using weightless exercise equipment. Six males(age, 23.00±0.73 years; height, 172.95±2.05 cm; body mass, 66.83±2.75 kg; and BMI, 22.33±0.72 kg/m2) completed this study as the subjects. Four type's high Plank exercises using weightless exercise equipment were performed(high plank, HP; high plank with air walker, HPAW; high plank with surf board, HPSB; high plank with waist trainer, HPWT). For the EMG analysis, we measured the body muscle activities of right side on the deltoid(DT), triceps brachii(TB), latissimus dorsi(LD), and external oblique(EO). This research's results were as follows. DT, TB, LD, & EO muscle activities were greatest during HPSB(p=.000). Therefore, these results are expected to serve as basic data for high Plank exercise using weightless exercise equipment performance applications in effective exercise programs.

Porting gcc Based eCos OS and PROFINET Communication Stack to IAR (gcc 기반 eCos 운영체제 및 PROFINET 통신 스택의 IAR 포팅 방법)

  • Jin Ho Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.4
    • /
    • pp.127-134
    • /
    • 2023
  • This paper describes how to port the eCos operating system and PROFINET communication stack developed based on gcc to the IAR compiler. The eCos operating system provides basic functions such as multi-thread, TCP/IP, and device driver for PROFINET operation, so there is no need to change it when developing PROFINET applications. Therefore, in this study, we reuse an eCos library built with gcc and it link with PROFINET communication stack that are ported to IAR complier. Due to the different of the gcc and IAR linker, symbol definitions and address of the constructors should be changed using the external tool that generates symbol definitions and address of the constructors from MAP file. In order to verify the proposed method, it was confirmed that the actual I/O was operating normally through PROFINET IRT communication by connecting to the Siemens PLC. IAR compiler has better performance in both the compile time and the size of the generated binary. The proposed method in this study is expected to help port various open sources as well as eCos and PROFINET communication stacks to other compilers.

Verification of the Difference in Effectiveness of Static Plank Exercise by Motion -Focusing on EMG Analysis- (정적 플랭크 운동의 동작 별 효과성 차이 검증 -근전도 분석을 중심으로-)

  • Kim, You-Sin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.335-339
    • /
    • 2022
  • The purpose of this research was to investigate the comparison of core muscle activities according to different performance in static Plank exercise. Ten "J" University's males(age, 23.20±0.65 years; height, 174.54±1.51 cm; body mass, 70.00±2.24 kg; and BMI, 22.94±0.51 kg/m2) completed this study as the subjects. Four type's static Plank motions were performed(full Plank, FP; elbow Plank, EP; side Plank, SP; reverse Plank, RP). For the EMG analysis, we measured the core muscle activities of right side on the rectus abdominis(RA), external oblique(EO), latissimus dorsi(LD), and erector spinae(ES). This research's results were as follows. LD and ES muscle activities were greatest during RP(p<.001). RA and EO muscle activities were greatest during EP(p<.001). Therefore, this results are anticipated to serve as basic data for static Plank performance applications in effective exercise programs.

A study on the dynamic performance of self-healing capsule based on carbonyl iron particles(CIPs) in magnetic field (자기장 환경에서 카르보닐철입자(CIPs) 기반 자가치유 캡슐의 동적 성능 분석에 관한 연구)

  • Cheng, Hao;Hu, Jie;Lim, Taeuk;Lee, Yeong Jun;Kim, Sangyou;Jung, Wonsuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.241-242
    • /
    • 2022
  • Recently, related studies on the application of bacterial spores to self-healing concrete have been widely reported. Using the self-healing method of bacterial spores as a kind of pro-environment, the green method is very attractive, but because the living environment of bacterial spores is relatively harsh, it is necessary to have a way to separate the living environment of bacterial spores from the harsh external environment, And release bacterial spores when needed. Therefore, capsules are widely used in self-healing concrete. To enhance the self-healing effect, the capsules need to be evenly distributed in the concrete. Furthermore, we develop a CIP-based smart capsule with controllability. We determined the magnetic force of each capsule by mixing CIP in resin, then mass-fabricating the capsules for self-healing by a microfluidic method, and by measuring the kinetic distance of the capsules containing different amounts of cip under the action of a magnetic field strength. The results show that with the increase of the amount of cip, the active distance of the capsule also increases. When the cip is 8wt%, the active distance reaches 1.75cm. We believe this research can provide momentum for the development of self-healing capsule applications.

  • PDF

Light Emitting Diode with Multi-step Quantum Well Structure for Sensing Applications (계단형 양자우물 구조가 적용된 센서 광원 용 발광다이오드 소자)

  • Seongmin Park;Seungjoo Lee;Jajeong Woo;Yukyung Kim;Soohwan Jang
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.441-446
    • /
    • 2023
  • Electrical and optical characteristics of the GaN-based light-emitting diode (LED) with the improved multi-quantum well (MQW) structure have been studied for light source in bio-sensing systems. Novel GaN/In0.1GaN/In0.2GaN/In0.1GaN/GaN and Al0.1GaN/GaN/In0.2GaN/GaN/Al0.1GaN (MQW) structures were suggested, and their radiative recombination rate, light output power, electroluminescence, and external quantum efficiency were compared with those of the conventional GaN/In0.2GaN/GaN MQW structure using device simulation. The LED with the GaN/In0.1GaN/In0.2GaN/In0.1GaN/GaN MQW structure showed an excellent recombination rate of 5.57 × 1028 cm-3·s-1 that was more than one order improvement over that of the conventional LED. In addition, the efficiency droop was relieved by the suggested stepped MQW structure.

Dynamic analysis of nanotube-based nanodevices for drug delivery in sports-induced varied conditions applying the modified theories

  • Shaopeng Song;Tao Zhang;Zhiewn Zhui
    • Steel and Composite Structures
    • /
    • v.49 no.5
    • /
    • pp.487-502
    • /
    • 2023
  • In the realm of nanotechnology, the nonlocal strain gradient theory takes center stage as it scrutinizes the behavior of spinning cantilever nanobeams and nanotubes, pivotal components supporting various mechanical movements in sport structures. The dynamics of these structures have sparked debates within the scientific community, with some contending that nonlocal cantilever models fail to predict dynamic softening, while others propose that they can indeed exhibit stiffness softening characteristics. To address these disparities, this paper investigates the dynamic response of a nonlocal cantilever cylindrical beam under the influence of external discontinuous dynamic loads. The study employs four distinct models: the Euler-Bernoulli beam model, Timoshenko beam model, higher-order beam model, and a novel higher-order tube model. These models account for the effects of functionally graded materials (FGMs) in the radial tube direction, giving rise to nanotubes with varying properties. The Hamilton principle is employed to formulate the governing differential equations and precise boundary conditions. These equations are subsequently solved using the generalized differential quadrature element technique (GDQEM). This research not only advances our understanding of the dynamic behavior of nanotubes but also reveals the intriguing phenomena of both hardening and softening in the nonlocal parameter within cantilever nanostructures. Moreover, the findings hold promise for practical applications, including drug delivery, where the controlled vibrations of nanotubes can enhance the precision and efficiency of medication transport within the human body. By exploring the multifaceted characteristics of nanotubes, this study not only contributes to the design and manufacturing of rotating nanostructures but also offers insights into their potential role in revolutionizing drug delivery systems.

Electrical and Optical Properties of Fluorine-Doped Tin Oxide Films Fabricated at Different Substrate Rotating Speeds during Ultrasonic Spray Pyrolysis Deposition (초음파 분무 열분해 증착 중 기판 회전 속도에 따른 플루오린 도핑 된 주석산화물 막의 전기적 및 광학적 특성)

  • Ki-Won Lee;yeong-Hun Jo;Hyo-Jin Ahn
    • Korean Journal of Materials Research
    • /
    • v.34 no.1
    • /
    • pp.55-62
    • /
    • 2024
  • Fluorine-doped tin oxide (FTO) has been used as a representative transparent conductive oxide (TCO) in various optoelectronic applications, including light emitting diodes, solar cells, photo-detectors, and electrochromic devices. The FTO plays an important role in providing electron transfer between active layers and external circuits while maintaining high transmittance in the devices. Herein, we report the effects of substrate rotation speed on the electrical and optical properties of FTO films during ultrasonic spray pyrolysis deposition (USPD). The substrate rotation speeds were adjusted to 2, 6, 10, and 14 rpm. As the substrate rotation speed increased from 2 to 14 rpm, the FTO films exhibited different film morphologies, including crystallite size, surface roughness, crystal texture, and film thickness. This FTO film engineering can be attributed to the variable nucleation and growth behaviors of FTO crystallites according to substrate rotation speeds during USPD. Among the FTO films with different substrate rotation speeds, the FTO film fabricated at 6 rpm showed the best optimized TCO characteristics when considering both electrical (sheet resistance of 13.73 Ω/□) and optical (average transmittance of 86.76 % at 400~700 nm) properties with a figure of merit (0.018 Ω-1).

Enhancing Transparency and Trust in Agrifood Supply Chains through Novel Blockchain-based Architecture

  • Sakthivel V;Prakash Periyaswamy;Jae-Woo Lee;Prabu P
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.7
    • /
    • pp.1968-1985
    • /
    • 2024
  • At present, the world is witnessing a rapid change in all the fields of human civilization business interests and goals of all the sectors are changing very fast. Global changes are taking place quickly in all fields - manufacturing, service, agriculture, and external sectors. There are plenty of hurdles in the emerging technologies in agriculture in the modern days. While adopting such technologies as transparency and trust issues among stakeholders, there arises a pressurized necessity on food suppliers because it has to create sustainable systems not only addressing demand-supply disparities but also ensuring food authenticity. Recent studies have attempted to explore the potential of technologies like blockchain and practices for smart and sustainable agriculture. Besides, this well-researched work investigates how a scientific cum technological blockchain architecture addresses supply chain challenges in Precision Agriculture to take up challenges related to transparency traceability, and security. A robust registration phase, efficient authentication mechanisms, and optimized data management strategies are the key components of the proposed architecture. Through secured key exchange mechanisms and encryption techniques, client's identities are verified with inevitable complexity. The confluence of IoT and blockchain technologies that set up modern farms amplify control within supply chain networks. The practical manifestation of the researchers' novel blockchain architecture that has been executed on the Hyperledger network, exposes a clear validation using corroboration of concept. Through exhaustive experimental analyses that encompass, transaction confirmation time and scalability metrics, the proposed architecture not only demonstrates efficiency but also underscores its usability to meet the demands of contemporary Precision Agriculture systems. However, the scholarly paper based upon a comprehensive overview resolves a solution as a fruitful and impactful contribution to blockchain applications in agriculture supply chains.

Evaluation on the Lost Prestressing Force of an External Tendon Using the Combination of FEM and HGA: II. Experimental Verification and Field Applications (FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가: II. 실험적 검증 및 현장적용)

  • Jang, Hang-Teak;Noh, Myung-Hyun;Park, Kyu-Sik;Park, Taehyo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.121-132
    • /
    • 2009
  • This paper introduces an experimental verification and a field application of the proposed technique using the combination of FEM and HGA about the loss prestressing force of an exteranl tendon by above same authors. The vibration tests have been conducted by using a laboratory models and the externally prestressed tendon at the field and the natural frequencies are extracted from the vibration tests. The proposed technique based on the extracted natural frequencies is applied. It is seen that the errors in the tension and lost prestressing force by proposed technique are about 4% from a laboratory model test. For the model verification at field, exact modeling has beem made with Rayleigh damping. It is seen that the error in the tension by proposed technique is less than 1% and the estimated lost prestressing force converges less than the exact value.

Bladder And Rectum Dose Define 3D Treatment Planning for Cervix Cancer Brachtherapy Comparison of Dose-Volume Histograms for Organ Contour and Organ Wall Contour (자궁경부암의 고선량률 근접치료시 장기묘사 방법에 따른 직장과 방광의 선량비교 분석)

  • Kim, Jong-Won;Kim, Dae-Hyun;Choi, Joon-Yong;Won, Yeong-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.327-333
    • /
    • 2012
  • Purpose: To analyze the correlation between dose volume histograms(DVH) based on organ outer wall contour and organ wall delineation for bladder and rectum, and to compare the doses to these organs with the absorbed doses at the bladder and rectum. Material and methods: Individual CT based brachytherapy treatment planning was performed in 13 patients with cervical cancer as part of a prospective comparative trial. The external contours and the organ walls were delineated for the bladder and rectum in order to compute the corresponding dose volume histograms. The minimum dose in 0.1 $cm^3$, 1 $cm^3$, 2 $cm^3$, 5 $cm^3$, 10 $cm^3$ volumes receiving the highest dose were compared with the absorbed dose at the rectum and bladder reference point. Results: The bladder and rectal doses derived from organ outer wall contour and computed for volumes of 2 $cm^3$, provided a good estimate for the doses computed for the organ wall contour only. This correspondence was no longer true when large volumes were considered. Conclusion: For clinical applications, when volumes smaller than 5 $cm^2$ are considered, the dose-volume histograms computed from external organ contours for the bladder and rectum can be used instead of dose -volume histograms computed for the organ walls only. External organ contours are indeed easier to obtain. The dose at the ICRU rectum reference point provides a good estimate of the rectal dose computed for volumes smaller than 2 $cm^2$ only for a midline position of the rectum. The ICRU bladder reference point provides a good estimate of the dose computed for the bladder wall only in cases of appropriate balloon position.