• Title/Summary/Keyword: exposure standards

Search Result 349, Processing Time 0.022 seconds

Analysis on the Risk of the Impermeable Concrete Bottom of Dikes for Nitric Acid Storage Tanks (질산 저장탱크 방류벽의 불침투성 콘크리트 바닥에 대한 위험성 평가)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.53-59
    • /
    • 2016
  • Considering the chemical reaction between concrete which is the raw material of the dike bottoms and hazardous chemicals, some chemicals can have negative effects on the impermeability of concrete dike bottoms. The impermeable standards for the concrete bottom of dikes have been made in the recent study, but the previous study was based on the exposure test to crude oil which is not corrosive and not related to the chemical reaction. It can be concluded that the test of crude oil can't represent all kinds of hazardous chemicals, especially highly corrosive chemicals. Meanwhile, this study has conducted the exposure test to nitric acid that is strongly corrosive and very hazardous. The results have showed that nitric acid has been penetrated at the maximum penetration depth of 2.9 cm for 7 days and the impermeable standards are better than the germany standard. Through this study with severe chemical, the scientific basis on the installation standards of all dike bottoms which are generally used in the industry has been obtained.

The Health Hazard Evaluation Program by NIOSH (NIOSH의 건강유해도 평가 프로그램)

  • Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.147-159
    • /
    • 2000
  • The NIOSH health hazard evaluation program (HHE program) was created in response to the mandate to determine the toxic effect and potential health hazard of workplace exposure, which is found in Occupational Safety and Health Act of 1970 and the Federal Mine Safety and Health Act of 1977, A primary benefit of HHE program is its ability to provide current health hazard data to employers and employees, which assists them in identifying solutions to occupational health and safety problems in their workplaces, The HHE program also stimulates research in the development and review of sampling methods and diagnostic tests and may prompt additional exposure assesment efforts and toxicological and epidemiological studies. HHE projects also provide human exposure-toxicity data that are used to asses the validity of existing occupational health standards and to support criteria for new standards of recommendation, The HHE request is classified into four categories: 1) category 1: As a administratively invalid, 2) category 2: These are valid requests for which a site visit is not essential to an appropriate response, 3) Category 3 : These are valid requests for which a site visit is necessary for an adequate evaluation, 4) These are valid request which present a complex problem or an opportunity for research, To carry out HHE program one or methods of investigation might be used: 1) direct observation and evaluation of production processes and employee work practices 2) employees exposure level and air contamination level 3) medical test or physical examinations of employees 4) private, confidential interviews with employees 5) review of employer's record of injuries and illness, employee exposure data, medical tests and job histories. After investigation and analysing the data, NIOSH issues a final report, giving finding and recommendation.

  • PDF

Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator (발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석)

  • Seong, Minyoung;Kim, Doo-Hyun;Kim, Seungtae
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.

Exposure Assessment to Suggest the Cause of Sinusitis Developed in Grinding Operations Utilizing Soluble Metalworking Fluids

  • Park, Dong-Uk;Choi, Byung-Soon;Kim, Shin-Bum;Kwag, Hyun-Seok
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.326-329
    • /
    • 2005
  • A worker who grinded the inner parts of camshafts for automobile engines using water-soluble metalworking fluid (MWF) for 14 years was diagnosed with sinusitis. We postulated that the outbreak of sinusitis could be associated with exposure to microbes contaminated in water-soluble MWF during the grinding operation. To suggest responsible agents for this outbreak, quantitative exposure assessment for chemical and biological agents and prevalence of work-related respiratory symptoms by questionnaire were studied. The exposure ranges of MWF mist (0.59 $mg/m^3$to 2.12 $mg/m^3$) measured during grinding exceeded 0.5 $mg/m^3$ of the recommended exposure limit (REL). Grinder's exposures to bacteria, fungi and endotoxins were also generally higher than not only the proposed standards, but also those reported by several studies to identify the cause of respiratory effects. Statistical test indicated that the prevalence rate of reported symptoms related to nasal cavities showed no significant differences among the operations. Evaluation on grinding operation characteristics and quantitative exposure assessment indicated that repeated exposure to MWF mist including microbes contaminated from the use of water-soluble MWF may cause respiratory diseases like sinusitis or at least increase susceptibility to the development of sinusitis

  • PDF

Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

Health Risk Assessment by Potential Exposure of NO2 and VOCs in Apartments (공동주택내 이산화질소(NO2) 및 휘발성유기화합물(VOCs) 노출에 따른 건강 위해성 평가)

  • Jung, Soon-Won;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.242-249
    • /
    • 2007
  • Indoor air quality has become a topic of interest and concern. Especially changes in construction design and the increased use of synthetic products may result in an increasing of complaints and health effects about the quality of indoor air at home. In this study, nitrogen dioxide($NO_2$) and volatile organic compounds(VOCs) within new and established apartments on the basis of 4 years of building year were measured every 3 days consecutively during 60 days. We selected each 10 house in Seoul, Asan and Daegu, respectively, and produced risk numbers for hazard quotients, and predicted increases in incidence of cancer. The calculations were made for the adult with default exposure values and also made for a worst case scenario using Monte-Carlo simulation as describing the reasonable exposure(RME). Mean of Monte carlo analysis by benzene, in the construction under 4 years (male: $9.2{\times}10^{-5}$, female: $1.0{\times}10^{-4}$) and over 4 years (male: $6.8{\times}10^{-5}$, female: $8.3{\times}10^{-5}$) exceeded $10^{-6}$ of permitted standards in US EPA, RME of Monte carlo analysis. In construction under 4 yews (male: $9.9{\times}10^{-3}$, female: $9.6{\times}10^{-3}$) and over 4 years (male: $9.8{\times}10^{-3}$, female: $7.8{\times}10^{-3}$) exceeded $10^{-4}$ of maximum permitted standards in US EPA. The hazard index of non-carcinogenic pollutants by nitrogen dioxide, toluene, m,p-xylene and o-xylene, both male and female in apartment constructed under 4 yews and over 4 years was found less than the permitted standards of hazardous health effects in CTE. Significant cancer risks and non-cancer hazard quotients were predicted in under 4 yews of building year.

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.

Modeling Human Exposure Levels to Airborne Volatile Organic Compounds by the Hebei Spirit Oil Spill

  • Kim, Jong-Ho;Kwak, Byoung-Kyu;Ha, Min-A;Cheong, Hae-Kwan;Yi, Jong-Heop
    • Environmental Analysis Health and Toxicology
    • /
    • v.27
    • /
    • pp.8.1-8.10
    • /
    • 2012
  • Objectives: The goal was to model and quantify the atmospheric concentrations of volatile organic compounds (VOCs) as the result of the Hebei Spirit oil spill, and to predict whether the exposure levels were abnormally high or not. Methods: We developed a model for calculating the airborne concentration of VOCs that are produced in an oil spill accident. The model was applied to a practical situation, namely the Hebei Spirit oil spill. The accuracy of the model was verified by comparing the results with previous observation data. The concentrations were compared with the currently used air quality standards. Results: Evaporation was found to be 10- to 1,000-fold higher than the emissions produced from a surrounding industrial complex. The modeled concentrations for benzene failed to meet current labor environmental standards, and the concentration of benzene, toluene, orthometa- para-xylene were higher than the values specified by air quality standards and guideline values on the ocean. The concentrations of total VOCs were much higher than indoor environmental criteria for the entire Taean area for a few days. Conclusions: The extent of airborne exposure was clearly not the same as that for normal conditions.

An Experimental Study on the Durability and Reinforcement Corrosion of Polymer Cement Based Repair Material (폴리머시멘트계 단면복구재의 내구성 및 철근부식특성에 관한 실험적 연구)

  • Kim Young Sun;Kim Young Duck;Na Chul Sung;Cho Bong Suk;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.487-490
    • /
    • 2005
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the data of indoor durability test and the data of the long term exposure test under the coast are accumulated and analyzed. As a result of the indoor test, durability of repair material was more superior to that of plain concrete, but as a result of investigating and evaluating exposure test at 30 month of exposure age under the coastal environment, the difference in electric potential and the reinforcement corrosion at place replaced with repair material are found.

  • PDF

Investigation of Validity of Exposure Limits for Electromagnetic Field in RF Band (RF 대역 전자계 노출기준의 타당성에 관한 연구)

  • 백정기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.4
    • /
    • pp.520-529
    • /
    • 1999
  • Exposure limits for human protection are determined by converting basic limits for induced current, SAR(specific absorption rate), or power density, which are based upon biological effects, to measurable electric and magnetic field intensities. As a part of studies for the establishment of a domestic guideline for exposure limits, the validity of the exposure limits of five representative guidelines or standards, which are derived from basic limits, are investigated in this paper, using the published results for coupling mechanisms of electromagnetic field into a human body, and problems in each standard are analyzed and compared with each other.

  • PDF