• Title/Summary/Keyword: experimental techniques

Search Result 3,189, Processing Time 0.039 seconds

Research on the Bamboo in Korea(Part 10) - On the Bending Test of Phyllostachys reticulata (한국산(韓國産)의 죽류(竹類)에 관(關)한 연구(硏究)(제(第)10보(報)) - Phyllostachys reticulata의 굴곡시험(屈曲侍險)에 대(對)하여 -)

  • Chong, Hyon Pae
    • Journal of Korean Society of Forest Science
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 1967
  • The bamboo is a plant whose culm grows straight up. This growing characteristics has been widely utilized in industry and craft. But the developments of handcraft making and horticultural techniques in recent years become to demand the bent bamboo culms. This study has been conducted at the experimental grove located at Hyunnae Ri, Okkye Myun, Myungju Gun, Kangwon Do since 1960. Although it has been known that the secret for which bamboo shoots complet growth within 40 odd days lies in their rhizomes, this writer felt the bamboo culm sheath might be another factor in addition. Hence some were stripped of sheath in this bending study as the following: 1. Time of sheath stripping. 2. Direction of sheath stripped for arbitrary bending. 3. Accuracy of bending following the size (growth) of bamboo shoots. The following results were obtained: 1. Bamboo shoots begin to appear in April. But the bamboo shot up in June showed the best bending result with 68% of bending efficiency. 2. Bending of the culm was facilitated by stripping off the sheath located on the side of the direction toward which bending was desired. By doing this, the culm could be bent as much as 90 degrees. But the culm totally stripped of sheath could be bent in any direction. 3. In order to determine the accuracy of bending of bamboo shoots growing, sheath were stripped off the shoots of which height ranged from 10 centimeter to 150 centimeters. The shoots with height of 110 centimeters showed the best result with 90%.

  • PDF

Clomiphene Citrate on Male Infertility (남성 불임증 환자에 대한 Clomiphene의 효과)

  • Lee, Kang-Hyun;Lee, Hee-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.8 no.2
    • /
    • pp.45-55
    • /
    • 1981
  • Clomiphene citrate. antiestrogen, was given to 39 infertile males whose spermatogenesis were disturbed and the efficacy of the drug was evaluated at the Department of Urology in 1980. (Table 1). Patients were divided into 3 clinical observation groups such as group I composed of 19 cases of idiopathic azoospermia, group II consisted of 15 cases of oligospermia following the vasovasostomy, and group III comprised 5 cases of testicular azoospermia. (Table 2). Clinical characteristics of these patients were as follows: Age of the patients ranged from 26 to 43 years old with mean of 34, and that of their wives ranged from 24 to 41 years old with mean of 31. Duration of marital life ranged from 1 to 21 years with mean of 5 years. Sizes of testis ranged from 6 to 25 ml with mean of 16 ml. Coital frequency ranged from 0.5 to 6 per week with mean of 2.4 per week. Levels of plasma FSH ranged from 3.15 to 23.06 lU/1 with mean of 8.15 lU/1, those of LH ranged from 2.98 to 19.89 lU/1 with mean of 8.18 lU/1 and those of testosterone ranged from 3.09 to 9.97 ng/ml with mean of 6.48 ng/ml. (Table 3). Clomiphene citrate was given in dosage of 50 mg per day (in d.) orally to 31 patients for 3 to 9 months and in dosage of 100 mg per day (b.i.d.) orally to 8 patients for 3 to 9 months. (Table 8). Semen samples were analysed monthly on each patient by routine analysis techniques. For the assessment of the efficacy of Clomiphene citrate on faulty spermatogenesis following empirical criteria were used: For semen quality: Improvement (I) represents that semen parameter increased more than 25% from basal level after the treatment, Unchange (U) expresses that semen parameter increased less than 25% of basal level or not changed after the treatment and Deterioration (D) means that semen parameter decreased from basal level after the treatment. For fertility unit (total counts ${\times}$ motility ${\times}$ morphology ${\div}10^6$): Improvement (I) represents that fertility unit increased more than 10 units after the treatment, Unchange (U) expresses that fertility unit increased less than 10 units or not changed after the treatment, and Deterioration (D) means that fertility unit decreased after the treatment. (Table 4). Results obtained from the Clomiphene therapy were as follows: Changes of spermiograme before and after the Oomiphene therapy shown in the Table 5. Sperm counts increased from 23 to 31 ${\times}10^6$/ml in group I, from 17 to 29 ${\times}10^6$/ml in group II. Other parameters of spermiogramme were not changed significantly after the treatment. Fertility units increased from 14 to 18 units after the treatment in group I, and from 16 to 18 units after the treatment in group II. Effectiveness of Clomiphene citrate on spermatogenesis was summarised in the Tables 6 and 7. After the treatment, sperm count increased in 11 patients, motility increased in 6 patients, morphology increased in 4 patients and fertility units increased in 9 patients. No sperm could be produced by Clomiphene citrate in group III of testicular azoospermia. Dosage of 50 mg of Clomiphene citrate per day for 3 to 6 months was proved to be the most effective in the present series. (Table 8). Pregnancy occurred in 2 patients after the treatment. No particular side effects were noted by the treatment. Pharmacologic compounds used for male infertility were shown in the Table 9. Reported results of Clomiphene citrate were shown in the Table 10.

  • PDF

Calculation of Dry Matter Yield Damage of Whole Crop Maize in Accordance with Abnormal Climate Using Machine Learning Model (기계학습 모델을 이용한 이상기상에 따른 사일리지용 옥수수 생산량 피해량)

  • Jo, Hyun Wook;Kim, Min Kyu;Kim, Ji Yung;Jo, Mu Hwan;Kim, Moonju;Lee, Su An;Kim, Kyeong Dae;Kim, Byong Wan;Sung, Kyung Il
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.4
    • /
    • pp.287-294
    • /
    • 2021
  • The objective of this study was conducted to calculate the damage of whole crop maize in accordance with abnormal climate using the forage yield prediction model through machine learning. The forage yield prediction model was developed through 8 machine learning by processing after collecting whole crop maize and climate data, and the experimental area was selected as Gyeonggi-do. The forage yield prediction model was developed using the DeepCrossing (R2=0.5442, RMSE=0.1769) technique of the highest accuracy among machine learning techniques. The damage was calculated as the difference between the predicted dry matter yield of normal and abnormal climate. In normal climate, the predicted dry matter yield varies depending on the region, it was found in the range of 15,003~17,517 kg/ha. In abnormal temperature, precipitation, and wind speed, the predicted dry matter yield differed according to region and abnormal climate level, and ranged from 14,947 to 17,571, 14,986 to 17,525, and 14,920 to 17,557 kg/ha, respectively. In abnormal temperature, precipitation, and wind speed, the damage was in the range of -68 to 89 kg/ha, -17 to 17 kg/ha, and -112 to 121 kg/ha, respectively, which could not be judged as damage. In order to accurately calculate the damage of whole crop maize need to increase the number of abnormal climate data used in the forage yield prediction model.

Characteristics Associated with Citation Rates of the Journal of Korean Orthopaedic Association (An Analysis of Articles between 2001-2015) (대한정형외과학회지에 발표된 논문들의 피인용 횟수와 연관된 특성(2001년부터 2015년까지의 논문 분석))

  • Bae, Jung Yun;Kwak, Sang Ho;Kang, Sang Woo;Woo, Seung Hun;Ahn, Tae Young;Lee, Sang Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.487-494
    • /
    • 2020
  • Purpose: No attempt has been made to identify the relationship between the study characteristics and citation rates of articles published in the Journal of the Korean Orthopaedic Association (JKOA). This study classified the study characteristics of articles in the JKOA and analyzed the relationship between the study characteristics and citation rates. Materials and Methods: A cohort study was conducted on all articles published from February 2001 to December 2015. Three independent reviewers classified the articles according to the article type, material, time of the study, design, clinical categories, number of authors, and number of cases. The citation numbers of each article by other journals were taken in January 2020. Univariate analyses were conducted to assess the effect of each characteristic, and multivariate linear regression analysis was performed to analyze the overall relationship between the characteristics and the citation rates. Results: A total of 1,640 articles were published from 2001 to 2015, and 724 articles were cited more than once. The articles published in 2009 had the highest average number of citations. Original articles had the highest citation rates, followed in descending order by surgical techniques and reviews, instructional course lectures, and case reports (p<0.001). Among the case reports, articles dealing with general trauma scored significantly higher average citations (mean=1.5, p=0.006). Among the original articles, articles on general orthopedics had the highest citation rates, followed in order by clinical articles and experimental articles. Among the clinical articles, epidemiologic studies (mean=5.0, p<0.001) and studies on the spine (mean=1.7, p<0.001) recorded significantly higher citation rates than the others. Conclusion: Of all the articles published in the JKOA from 2001 to 2015, articles dealing with general trauma had the highest citation rates among case reports. Among the original articles, epidemiologic studies and studies concerning the spine were cited significantly more than others.

Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance (이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발)

  • Ki-Yeol Eom;Byeong-Seok Min
    • Journal of Internet Computing and Services
    • /
    • v.25 no.1
    • /
    • pp.99-107
    • /
    • 2024
  • Along with economic growth and industrial development, there is an increasing demand for various electronic components and device production of semiconductor, SMT component, and electrical battery products. However, these products may contain foreign substances coming from manufacturing process such as iron, aluminum, plastic and so on, which could lead to serious problems or malfunctioning of the product, and fire on the electric vehicle. To solve these problems, it is necessary to determine whether there are foreign materials inside the product, and may tests have been done by means of non-destructive testing methodology such as ultrasound ot X-ray. Nevertheless, there are technical challenges and limitation in acquiring X-ray images and determining the presence of foreign materials. In particular Small-sized or low-density foreign materials may not be visible even when X-ray equipment is used, and noise can also make it difficult to detect foreign objects. Moreover, in order to meet the manufacturing speed requirement, the x-ray acquisition time should be reduced, which can result in the very low signal- to-noise ratio(SNR) lowering the foreign material detection accuracy. Therefore, in this paper, we propose a five-step approach to overcome the limitations of low resolution, which make it challenging to detect foreign substances. Firstly, global contrast of X-ray images are increased through histogram stretching methodology. Second, to strengthen the high frequency signal and local contrast, we applied local contrast enhancement technique. Third, to improve the edge clearness, Unsharp masking is applied to enhance edges, making objects more visible. Forth, the super-resolution method of the Residual Dense Block (RDB) is used for noise reduction and image enhancement. Last, the Yolov5 algorithm is employed to train and detect foreign objects after learning. Using the proposed method in this study, experimental results show an improvement of more than 10% in performance metrics such as precision compared to low-density images.

Parafoveal Preview Effects on Semantic Relatedness in Eye Movement Tracking (안구운동 추적을 통해 살펴본 중심와주변 정보의 의미적 관련 정도에 따른 미리보기 효과)

  • Wang, Shang;Choo, Hyeree;Koh, Sungryoung
    • Korean Journal of Cognitive Science
    • /
    • v.35 no.2
    • /
    • pp.129-159
    • /
    • 2024
  • In the process of reading, readers can process information not only within the fixated region, known as the fovea, but also in the parafoveal region to the right of the fovea. While the parafoveal semantic preview effect has been confirmed in eye-tracking experiments using boundary techniques, research on how the parafoveal preview effects differ depending on the degree of semantic relatedness is still limited. This study investigates the parafoveal preview effects as a function of semantic relatedness with the target word. The experiment utilized Korean-Chinese bilinguals and presented mixed-language sentences as experimental stimuli. Four parafoveal preview conditions were applied to the target words in each sentence: (1) Korean identical condition, where the parafoveal word was the same as the target word (e.g., "나라," meaning "country" in English), (2) Chinese synonymous condition, where the parafoveal word had the same meaning as the target word (e.g., "国家," also meaning "country" in English), (3) Chinese semantically related condition, where the parafoveal word was semantically related to the target word (e.g., "政权," meaning "political power" in English), and (4) Chinese unrelated condition, where the parafoveal word was semantically unrelated to the target word (e.g., "围裙," meaning "apron" in English). The study explored the parafoveal preview effect in terms of the degree of semantic association with the target word. We found the most pronounced preview effect in conditions where the preview and the target word shared the same meaning, and we also observed preview effects in conditions where the semantic relatedness with the target word was relatively weak. This study suggests that the degree of semantic relatedness between the parafoveal preview word and the target word can influence readers' reading processes. It contributes to a better understanding of readers' eye movements and comprehension processes, with potential implications for the development of effective reading strategies and educational methods.

Studies on the Environmental Factors Affecting the Cocoon Crops in Summer and Autumn in Korea (한국의 하추잠작 안정을 위한 환경요인에 관한 연구)

  • 이상풍
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.2
    • /
    • pp.1-34
    • /
    • 1974
  • These experiments pertain to various factors influencing the quantitative characters of cocoon crops in summer and early autumn seasons. Initially, in order to establish the possible ways of the silkworm rearing more than three times a year in Korea, the author attempted to get further information about the various factors affecting the cocoon crop in every silkworm rearing season. The trials were conducted eleven times a year at four places for three years. The field trial was conducted with 19 typical sericultural farmers who had been surveyed. At the same time the author statistically analyzed the various factors in close relation to tile cocoon crop in autumn season. The effect of guidance on 40 sericultural farmers was analyzed, comparing higher level farmers with lower level farmers ; and the author surveyed 758 non-guided farmers near the guided farmers during both spring and autumn seasons. In addition, another trial on the seasonal change of leaf quality was attempted with artificial diets prepared with leaves grown in each season. It was found that related factors to cocoon crops in summer and early autumn seasons appeared to be leaf quality, and temperature for young and grown larvae. A 2$^4$ factorial experiment was designed in summer season, and another design with one more level of varied temperature or hard leaf added to a 24 factorial experiment was conducted in early autumn. The experimental results can be summarized: 1. Study on the cocoon crops in the different rearing seasons 1) It was shown that earlier brushing of silkworm generally produced the most abundant cocoon crop in spring season, and earlier or later than the conventional brushing season, especially earlier brushing was unfavorable for the abundant cocoon crop in autumn season. 2) The cocoon crop was affected by the rearing season, and decreases in order of sire with spring, autumn, late autumn, summer and early autumn seasons. 3) It was Proved that ordinary rearing and branch rearing were possibles 4 times a year ; in the 1st, 3rd, 8th, and 10th brushing season. But the 11th brushing season was more favorable for the most abundant cocoon crop of branch rearing, instead of the 10th brushing season with ordinary rearing. 2. Study on the main factors affecting the cocoon crop in autumn season 1) Accumulated pathogens were a lethal factor leading to a bad cocoon crop through neglect of disinfection of rearing room and instruments. 2) Additional factors leading to a poor cocoon crop were unfavorable for rearing temperature and humidity, dense population, poor choice of moderately ripened leaf, and poor feeding techniques. However, it seemed that there was no relationship between the cocoon crop and management of farm. 3) The percentage of cocoon shell seemed to be mostly affected by leaf quality, and secondarily affected by the accumulation of pathogens. 3. Study on the effect of guidance on rearing techniques 1) The guided farms produced an average yearly yield of 29.0kg of cocoons, which varied from 32.3kg to 25.817g of cocoon yield per box in spring versus autumn, respectively. Those figures indicated an annual average increase of 26% of cocoon yield over yields of non-guided farmers. An increase of 20% of cocoon yield in spring and 35% of cocoon yield in autumn were responsible. 2) On guided farms 77.1 and 83.7% of total cocoon yields in the spring and autumn seasons, respectively, exceeded 3rd grade. This amounted to increases of 14.1 and 11.3% in cocoon yield and quality over those of non-guided farms. 3) The average annual cocoon yield on guided farms was 28.9kg per box, based on a range of 31.2kg to 26.9kg per box in spring and autumn seasons, respectively. This represented an 8% increase in cocoon yield on farms one year after guidance, as opposed to non-guided farms. This yield increase was due to 3 and 16% cocoon yield increases in spring and autumn crops. 4) Guidance had no effect on higher level farms, but was responsible for 19% of the increases in production on lower level farms. 4. Study on the seasonal change of leaf quality 1) In tests with grown larvae, leaves of tile spring crop incorporated in artificial diets produced the best cocoon crop; followed by leaves of the late autumn, summer, autumn, and early autumn crops. 2) The cocoon crop for young larvae as well as for grown larvae varied with the season of leaf used. 5. Study on factors affecting the cocoon crops in summer and early autumn A. Early autumn season 1) Survival rate and cocoon yield were significantly decreased at high rearing temperatures for young larvae 2) Survival rate, cocoon yield, and cocoon quality were adversely affected by high rearing temperatures for grown larvae. Therefore increases of cocoon quantity and improvement of cocoon quality are dependent on maintaining optimum temperatures. 3) Decreases in individual cocoon weight and longer larval periods resulted with feeding of soft leaf and hard leaf to young larvae, but the survival rate, cocoon yield and weight of cocoon shell were not influenced. 4) Cocoon yield and cocoon quality were influenced by feeding of hard leaf to grown larvae, but survival rate was not influenced by the feeding of soft leaf and hard leaf. 5) When grown larvae were inevitably raised at varied temperatures, application of varied temperature in the raising of both young and grown larvae was desirable. Further research concerning this matter must be considered. B. Summer season 1) Cocoon yield and single cocoon weight were decreased at high temperatures for young larvae and survival rate was also affected. 2) Cocoon yield, survival rate. and cocoon quality were considerably decreased at high rearing temperatures for grown larval stages.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

A Study of the Relationship between Realistic Expression of Objects and Graphic Novel in Korean Comics - Focused on the work by Kwon, Ga-Ya - (한국만화에 있어 대상의 사실적 표현과 그래픽 노블의 연관관계에 대한 연구 - 권가야의 <남한산성>작품을 중심으로 -)

  • Park, Hee-Bok;Kim, Kwang-Su
    • Cartoon and Animation Studies
    • /
    • s.37
    • /
    • pp.361-392
    • /
    • 2014
  • Regarding works that express objects realistically in painting, Gustave Courbet advocated realism in the mid-19th century, France, resisting the then academist style of painting, and works in realist style were produced in earnest by painters such as H. Daumier or Jean F. Millet, who went along with him. Later, realism has expanded into the realm of general literature, including fine art, which has had profound impacts on works of art and literary works. In comics, too, in the same historical context as a form of painting, realistic comics began to be produced by painters or cartoonists at the time. These realism comics are those dealing with stories based on facts, and in terms of contents, objective description and representation of the social realities of the times is one of the most important objectives, but it could not be concluded that in their visual aspect, that is, that of expressing the objects, they were realistic. In the meantime, a graphic novel was born, which was the intermediate form between comics and novels around the United States and Europe since the 1980s. Graphic novels appeared in forms and styles with strong literary and artistic values in the comics market in the U.S. which was full of the superhero genre (comics around heroes), and their major characteristics are very realistic expressions in terms of contents and visual aspect. They are complex and delicate and even have artistic, literary values as if readers read a fiction or literary work of which its narrative structures or pictures are produced with graphics. The characteristics of realistic expressions shown in graphic novels are very different from the previous works of comics. It is noteworthy that they began to be acknowledged as works of art like painting or illustration, thanks to their features of strongly individual auteurist painting style, a fairly high degree of completion of the works, and creative and experimental expression techniques or methods, instead of following the fashion of the times. In recent years, in South Korea, Hollywood blockbuster films have been released one after another and become box office hits, there are increasing interest and demand for the original graphic novels. Accordingly, many original graphic novels have been translated and started to be sold, and keeping pace with this global flow of fashion, some writers in Korea began to produce works of graphic novels. However, to look into the domestic works produced claiming to be graphic novels, there are various opinions on their format and authenticity. In this sense, this study focused on Ga-ya Kwon's Namhansanseong, one the representative works of Korean style graphic novels, and in particular, it attempted to analyze their characteristics and commonalities focusing on the visual aspect of realistic expressions of objects. It is expected that there would be an opportunity to seek for ways so that Korean style graphic novel can be further developed as a genre of comics, with competitiveness by looking back on the identity and present state of domestic graphic novels and developing and applying Korea's original subject matters differentiated from those of graphic novels in the U.S., Europe or Japan through this study. In addition, it is desired that they will be a new energizer for the stagnant domestic comics market.