• Title/Summary/Keyword: experimental program

Search Result 6,505, Processing Time 0.038 seconds

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

Optimal Nozzle Design of Bladeless Fan Using Design of Experiments (실험계획법을 이용한 날개 없는 선풍기의 노즐 형상 최적 설계)

  • Jeong, Siyoung;Lee, Jongsoo;Yoon, Jaehyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.711-719
    • /
    • 2017
  • Bladeless fan is becoming increasingly popular owing to its advantages, such as improved safety, easy to clean, and attractive shape. However, many people are reluctant to purchase it because of several disadvantages, such as noise and moderate wind; therefore, research on how improve wind generation without increasing the motor speed is required. This study investigates the optimization of the shape of the nozzle and nearby surface using CFD (Computational Fluid Dynamics) simulation, ANSYS fluent. The results are analyzed by ANOM (analysis of mean) and interaction analysis; therefore this study suggests the variables of affecting Coanda effect and satisfy the govern equation, the conservation of momentum. The optimal combination was found through a predictive equation. In this study, factors and levels that affect the mass flow rate were selected and experimental points were arranged using the orthogonal array table. The value of the mass flow rate was confirmed by ANSYS fluent, which is a CFD program. Through the ANOM, it was confirmed that the nozzle distance is the most influential parameter affecting the mass flow rate. Furthermore, the mass flow rate obtained from the predictive equation and the mass flow rate from the CFD correspond to the largest values. Results from this study confirmed that the mass flow rate is increased by a change in the shape, even if the motor speed did not increase.

FlaSim: A FTL Emulator using Linux Kernel Modules (FlaSim: 리눅스 커널 모듈을 이용한 FTL 에뮬레이터)

  • Choe, Hwa-Young;Kim, Sang-Hyun;Lee, Seoung-Won;Park, Sang-Won
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.11
    • /
    • pp.836-840
    • /
    • 2009
  • Many researchers have studied flash memory in order to replace hard disk storages. Many FTL algorithms have been proposed to overcome physical constraints of flash memory such as erase-before-write, wear leveling, and poor write performance. Therefore, these constraints should be considered for testing FTL algorithms and the performance evaluation of flash memory. As doing the experiments, we suffer from several problems with costs and settings in experimental configuration. When we, for example, replay the traces of Oracle to evaluate the I/O performance with flash memory, it is hard to extract exact traces of I/O operations in Oracle. Since there are only write operations in the log, it is impossible to gather read operations. In MySQL and SQLite, we can gather the read operations by changing I/O functions in the source codes. But it is not easy to search for the exact points about I/O and even if we can find out the points, we might get wrong results depending on how we modify source codes to get I/O traces. The FlaSim proposed in this paper removes the difficulties when we evaluate the performance of FTL algorithms and flash memory. Our Linux drivers emulate the flash memory as a hard disk. And we can easily obtain the usage statistics of flash memory such as the number of write, read, and erase operations. The FlaSim can be gracefully extended to support the additional modules implemented by novel algorithms and ideas. In this paper, we describe the structure of FTL emulator, development tools and operating methods. We expect this emulator to be helpful for many experiments and research with flash memory.

Springback Minimization using Bottoming in Al Can Deep Drawing Process (알루미늄 캔 딥드로잉에서 Bottoming을 이용한 스프링백 최소화)

  • Park, Sang-Min;Lee, Sa-Rang;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.302-307
    • /
    • 2016
  • The technology of multistage deep drawing has been widely applied in the metal forming industry, in order to reduce both the manufacturing cost and time. A battery can used for mobile phone production is a well-known example of multistage deep drawing. It is very difficult to manufacture a battery can, however, because of its large thickness to height aspect ratio. Furthermore, the production of the final parts may result in assembly failure due to springback after multistage deep drawing. In industry, empirical methods such as over bending, corner setting and ironing have been used to reduce springback. In this study, a bottoming approach using the finite element method is proposed as a practical and scientific method of reducing springback. Bottoming induces compression stress in the deformed blank at the final stroke of the punch and, thus, has the effect of reducing springback. Different cases of the bottoming process are studied using the finite element program, DYNAFORM, to determine the optimal die design. The results of the springback simulation after bottoming were found to be in good agreement with the experimental results. In conclusion, the proposed bottoming method is expected to be widely used as a practical method of reducing springback in industry.

Performance Ability after CPR Education of the ground workers in an airport (공항 지상 근무자의 심폐소생술 수행능력)

  • Shin, Ji-Hoon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.29-40
    • /
    • 2009
  • Objective : This study is an experimental study which is designed to examine the differences between knowledge and self-confidence before and after theory education(CPR PPT material) based on guidelines of CPR and emergency cardiac treatment of American Heart Association(AHA, 2005) and video self-instruction program for the general public by Korean Association of Cardiopulmonary Resuscitation(KACPR), trace CPR performance ability after CPR and AED education and investigate the accuracy of artificial respiration and chest compression, and know the difference in CPR performance abilities including AED. Methods : Subjects of this study include ground crews and staffs at M airport in G province equipped with emergency equipments for CPR according to Art. 47, Sec. 2 of Emergency Medical Law, airport police, rent-a-cops, security guard, quarantine officer, custom officer, and communication, electricity, civil engineering, facility management staff, airport fire fighting staff, air mechanic, traffic controller, and airport management team among airport facility management staffs. They were given explanation of necessity of research and 147 of 220 subjects who gave consent to this research but 73 who were absent from survey were excluded were used as subjects of this study. of 147 subjects, there were 102 men and 45 women. Results : 1) Knowledge score of CPR was $6.18{\pm}0.87$ before instruction and it was increased to $15.12{\pm}1.78$ after instruction, and there was statistically significant difference. 2) Self-confidence score in CPR was $3.16{\pm}0.96$ before instruction and it was increased to $7.05{\pm}0.75$ after instruction, and there was statistically significant difference. 3) Total average score in CPR performance ability after instruction was 7.46 out of 9, performance ability was highest in confirmation of response as 144(97.95%), follwed by request of help as 140(95.25%) and confirmation of respiration as 135(91.83%), and lowest in performing artificial respiration twice(gross elevation of chest) as 97(65.98%). Accuracy of artificial respiration(%) was $28.60{\pm}16.88$ and that of chest compression(%) was $73.10{\pm}22.16$. 4) Performance ability of AED after instruction showed proper performance in power on by 141(95.91%) and attaching pad by 135(91.83%), hand-off for analyzing rhythm showed 'accuracy' in 115(78.23%) and 'non-performance' in 32(21.77%), delivery of shock and hand-off confirmation showed 'accuracy' in 109(74.14%) and 'inaccuracy' in 38(25.86%), and beginning chest compression immediately after AED was done by 105(71.42%).

  • PDF

The Effect of Mental Practice with Task Activities on Upper Limbs Movement Speed and Accuracy of Ideomotor Apraxia Patients : Single Subject Experimental Research (상상연습과 과제활동 병행 치료가 관념운동 실행증 환자의 상지 움직임 속도와 정확성에 미치는 효과: 단일사례 실험연구)

  • Lee, Jae-Hong;Jang, Jong-Sik;Lee, Jae-Shin
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.11-22
    • /
    • 2014
  • Objective : The purpose of this study is to investigate the effect of mental practice with task activities through upper limbs movement speed and accuracy in ideomotor apraxia patient. Methods : As a single subject research design with multiple baseline across individuals, the patients were two ideomotor apraxia patients, employed in this study. The employed program included receiving mental practice and task activities, measuring change of the total performance times, time to put down the last cups and amount of water in cups for 4 weeks, including baseline and intervention periods. The subject were measured by Ideomotor apraxia test and MFT were analyzed. The analyses were performed using visually and two-standard deviation band method. Results : All subjects were a reduction in symptoms of apraxia, but noticeable change in upper limbs function was not there. Total time of performance from 376.67 to 355.24 seconds, 391.33 seconds to 434.60 seconds, reduced. Put down the cup of performance time from 15.67 to 13.30 seconds, 20.80 seconds to 10.73 seconds, reduced. The amount of water transferred from 52.38ml to 49.70ml, 50.89ml to 50.09ml, all results were closer to 50ml. Conclusion : As a result of this study, mental practice with task activities can be an effective method to ideomotor apraxia patients. This study would serve a fundamental data on ideomotor apraxia patients to the further studies.

  • PDF

Relationship of Orofacial Pain and Sleep Quality (수면의 질과 구강 안면 통증의 관계)

  • Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.91-99
    • /
    • 2006
  • This study was performed to investigate about sleep quality and orofacial pain pattern between experimental and control group. 101 subjects with temporomandibular disorders without any psychologic and neurologic problem were selected from the patients presented to Wonkwang University dental hospital. Routine clinical examination for TMD was carried out, especially for the frequency of headache and the craniocervical muscles were also done by the author in the first visit. All the subjects filled out the questionnaires, that was, for the evaluation of sleep quality using Pittsburgh sleep quality index(PSQI), and for the analysis of behavioral pain scale questionnaires. Data obtained were statistically processed by the SPSS Windows program and the results of this study were as follows: 1. Subjective sleep index, sleep latency, sleep disturbance, global score in control group were significantly lower than 2. Subjective sleep index, sleep disturbance, global score in subject with headache were significantly lower than subject without headache(P<0.05). 3. Medicine taker have sleeping drug. Caffeine drinkers was significantly higher in daytime dysfunction, global score than no drinker. 4. It have more frequent head and neck pain, pain spreading, daily life difficult in poor sleeper than good sleeper.

Evaluation on machining accuracy according to convergence angle and radius of curvature value used for fabricating custom abutments (맞춤형 지대주 제작에 사용되는 수렴 각과 곡률 반경의 값에 따른 가공 정확도 평가)

  • Hong, Min-Ho;Choi, Sung-Min;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.329-336
    • /
    • 2017
  • This study evaluates the machining accuracy of the custom abutment design according to the selected convergence angle and radius of curvature value in the CAD program. Ten custom abutments were designed based on dental CAD. And then, the fabricated custom abutment was scanned ten times using a contact scanner. The data of the scanned custom abutment was saved as "Test STL" file. The Geomagic studio software was used to superposition each exported as an "Test STL" file with the CAD-reference-model STL file (CRM) specified by the same name. In the experimental results, the A8 group (convergence angle $8^{\circ}$) showed lower error than the A4 group (convergence angle $4^{\circ}$) . In addition, the higher the radius of curvature, the less error in the top and chamfer regions of the custom abutment (p< 0.05). Overall, the convergence angle and radius of curvature value in the custom abutment design were found to affect the machining accuracy.

Cardiac physiologic regulation of sub-type specific adrenergic receptors in transgenic mice overexpressing β1- and β2-adrenergic receptors.

  • Kim, Ka Eul;Tae, Hyun-Jin;Natalia, Petrashevskaya;Lee, Jae-Chul;Ahn, Ji Hyeon;Park, Joon Ha;Kim, In Hye;Ohk, Taek Geun;Park, Chan Woo;Cho, Jun Hwi;Won, Moo-Ho
    • Clinical and Experimental Emergency Medicine
    • /
    • v.3 no.3
    • /
    • pp.175-180
    • /
    • 2016
  • Objective Combination of ${\beta}_1-adrenergic$ receptor (AR) blockade and ${\beta}_2-AR$ activation might be a potential novel therapy for treating heart failure. However, use of ${\beta}-AR$ agonists and/or antagonists in the clinical setting is controversial because of the lack of information on cardiac inotropic or chronotropic regulation by AR signaling. Methods In this study, we performed hemodynamic evaluation by examining force frequency response (FFR), Frank-Starling relationship, and response to a non-selective ${\beta}-AR$ agonist (isoproterenol) in hearts isolated from 6-month-old transgenic (TG) mice overexpressing ${\beta}_1-$ and ${\beta}_2-ARs$ (${\beta}_1-$ and ${\beta}_2-AR$ TG mice, respectively). Results Cardiac physiologic consequences of ${\beta}_1-$ and ${\beta}_2-AR$ overexpression resulted in similar maximal response to isoproterenol and faster temporary decline of positive inotropic response in ${\beta}_2-AR$ TG mice. ${\beta}_1-AR$ TG mice showed a pronounced negative limb of FFR, whereas ${\beta}_2-AR$ TG mice showed high stimulation frequencies with low contractile depression during FFR. In contrast, Frank-Starling relationship was equally enhanced in both ${\beta}_1-$ and ${\beta}_2-AR$ TG mice. Conclusion Hemodynamic evaluation performed in the present showed a difference in ${\beta}_1-$ and ${\beta}_2-AR$ signaling, which may be due to the difference in the desensitization of ${\beta}_1-$ and ${\beta}_2-ARs$.

Effects of Retort Sterilization on Quality Characteristics of the Imitation Crab Leg (레토르트 살균처리가 게맛어묵의 품질특성에 미치는 영향)

  • Kang, Jin-Yeong;Yun, Jae-Ung;Hwang, Seok-Min;Kang, Jeong-Gu;Kim, Nam-Woo;Oh, Kwang-Soo
    • Journal of agriculture & life science
    • /
    • v.44 no.6
    • /
    • pp.147-157
    • /
    • 2010
  • This study was carried out to develop the normal temperature-circulatable retort sterilized imitation crab leg (RSIC) with long shelf-life by retort sterilization. We have examined the optimum retort sterilization conditions and quality characteristics of the RSIC. Central composite design for response surface methodology (RSM) was adopted for optimization of retort sterilization, and experimental central composite design consisted of 11 samples such as 4 factorial points; 4 star points; 3 central points. Sterilization temperature and $F_0-value$ for retort sterilization were chosen for independent variables, and shearing force, whiteness and sensory score about texture were selected as a dependent variable. As a results of RSM analysis, multiple response optimization for the RSIC by Minitap statistical programing was $F_0-value$ 3.3 min. at $117.5{^{\circ}C}$. Also RSM analysis indicated such as sterilization temperature during retort sterilization was the most influential factor, while $F_0-value$ little affected on quality of the RSIC.