• Title/Summary/Keyword: experimental apparatuses

Search Result 50, Processing Time 0.023 seconds

A Study on the Compression Characteristics of Bi-polymer O-rings (복합소재 O-링의 압축변형 특성에 관한 연구)

  • Kim, Do-Hyun;Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • v.21 no.4
    • /
    • pp.171-176
    • /
    • 2005
  • O-ring seal is an essential component in various mechanical apparatuses for a sealing of oil container and pressure vessels. This paper presents the sealing pressure and compressive contact behaviors of hi-polymer O-rings, which is made by an outer shell of FFKM material and an inner solid ring of FKM one. The contact normal pressure and its ratios are measured by experimental method with an automatic control system of the working temperature and analyzed numerically by using the non-linear Marc FEM program. The results show reasonably good agreements between the computed FEM results and measured ones when the operating temperature is kom normal temperature of $18^{\circ}C$ and a high temperature of $300^{\circ}C$ But the compared values between the computed and tested results show a little difference because of the increased temperature, which is related to the non-linear parameter of the O-ring material. Bi-polymer 0-ring shows a good contact normal stress and compression behavior for a given operation temperature and compression ratio.

The study on the estimation of heat transfer coefficient through the counterflow concentric tube using refrigerant and moisture air (냉매와 습공기가 교차하는 2중관에서 전열계수 예측을 위한 연구)

  • 조권희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.687-694
    • /
    • 1999
  • This study was conducted to develop new drying process for automatic control and marine engi-neering system. Air-water tests were carried out to investigate dryer performance. The dispersed flow in he dryer test apparatuses was also simulated by using a numerical code which solves the Dittus-Boelter equation for continuous liquid phase and the Reynolds equation of droplet motion for continuous liquid phase and the Reynolds equation of droplet motion for dispersed phase to predict droplet removal efficiency. Proper conditions for dehumidification were optimized by response ambient conditions. When the selected indexes were constrained in the range of 85-98% moisture content above $15^{\circ}$ and more than mass flow rates of moist air 750kg/h. The numerical results were compared with the experimental data pertaining to the removal effi-ciency at chamber stage and overall pressure drop along concentric tubes Good agreement was obtained as for the efficiency while relatively poor agreement was obtained for the relative humidity. The results also showed that the efficiency depended strongly on the relative humidity at the inlet condition which indicated the importance of estimating the heat exchanger length. Effects of some design parameters in both removal efficiency and breakthrough onset condition are discussed.

  • PDF

Design and Development of Sensor-based Virtual Experiment Contents for Smart Phone (스마트폰의 센서를 이용한 가상 실험 콘텐츠의 개발 및 설계)

  • Chung, Kwang Sik;Kwon, Sooyoul;Huang, Wen-Hao
    • Journal of Digital Contents Society
    • /
    • v.14 no.2
    • /
    • pp.161-169
    • /
    • 2013
  • Experiments and practices are critical instructional activities for teaching and learning natural sciences. However, by learning the experimental procedures in advance with the help of Virtual Experiments, natural science majors may address danger of handling chemicals before carrying out experiments in the laboratories. Virtual Experiments, a mobile learning app, provides learners with interactions between the learners and the contents by using the sensor built-in Android-platform smart phones. With the app, learners may handle the chemicals and experiment apparatuses, verify the reactions and assembly of the chemicals and instruments in advance. This paper describes the design and development of the Virtual Experiments in hope to promote the integration of mobile learning apps in order to better engage learners in the laboratories.

Electrical Insulation Characteristics of Insulators in Cryogenic Liquid for a HTS Apparatus (고온초전도 기기를 위한 극저온 액체 중 절연물의 전기적 특성)

  • Baek, Seung-Myeong;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Kim, Sang-Hyun;Kim, Hyun-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.263-264
    • /
    • 2006
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of insulators in cryogenic liquid such as liquid nitrogen ($LN_2$) is essential. So in this paper, we discussed experimental investigations of breakdown and V-t characteristics of several insulators such as Kapton and glass fiber reinforced plastic (GFRP) that are candidates of insulator for HTS apparatus in cryogenic liquid. And we investigated the degradation of these insulation samples after breakdown with the microscope and SEM photograph. Moreover, survival and hazard analysis were performed.

  • PDF

A Study on the Development of Automatic Ship Berthing System (선박 자동접안시스템 구축을 위한 기초연구)

  • Kim, Y.B.;Choi, Y.W.;Chae, G.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.139-146
    • /
    • 2006
  • In this paper vector code correlation(VCC) method and an algorithm to promote the image processing performance in building an effective measurement system using cameras are described for automatically berthing and controlling the ship equipped with side thrusters. In order to realize automatic ship berthing, it is indispensable that the berthing assistant system on the ship should continuously trace a target in the berth to measure the distance to the target and the ship attitude, such that we can make the ship move to the specified location. The considered system is made up of 4 apparatuses compounded from a CCD camera, a camera direction controller, a popular PC with a built in image processing board and a signal conversion unit connected to parallel port of the PC. The object of this paper is to reduce the image processing time so that the berthing system is able to ensure the safety schedule against risks during approaching to the berth. It could be achieved by composing the vector code image to utilize the gradient of an approximated plane found with the brightness of pixels forming a certain region in an image and verifying the effectiveness on a commonly used PC. From experimental results, it is clear that the proposed method can be applied to the measurement system for automatic ship berthing and has the image processing time of fourfold as compared with the typical template matching method.

  • PDF

Investigation of System Efficiency of an Electro-hydrostatic Actuator with an External Gear Pump (소형 외접기어펌프를 사용하는 EHA의 시스템 효율 분석)

  • Kim, Jong-Hyeok;Hong, Yeh-Sun
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.15-21
    • /
    • 2019
  • In this study, the maximum system efficiency of the electro-hydrostatic actuators was experimentally investigated, where small size external gear pumps with volumetric displacement under 1.3 cc/rev were combined with a 400W servomotor as the prime mover. Since the efficiency data of the servomotor, gear pumps and hydraulic cylinder were not provided by the suppliers, experimental apparatuses for their efficiency measurement were extra built up. When a gear pump with a volumetric displacement of 1.27cc/rev was used on an electro-hydrostatic actuator system, the maximum system efficiency was not higher than 70%. This was because the most effective operation ranges of the motor and pump did not coincide each other. In order to match their operation ranges as one of the most crucial design factors, a speed reduction mechanism can be used, such as a timing belt. It was shown in the study that the maximum system efficiency could be increased from 70% to 76% in that way.

A Study on the MESG of Flammable Ternary Gas Mixtures (3성분계 인화성 혼합가스의 MESG에 관한 연구)

  • Hwang, Kyungyong;Byeon, Junghwan;Rhee, Kyunam;Lee, Taeck-Kie
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.30-37
    • /
    • 2016
  • Electrical apparatuses for use in the presence of flammable gas atmospheres have to be specially designed to prevent them from igniting the explosive gas. Flameproof design implies that electrical components producing electrical sparks are contained in enclosures and withstand the maximum pressure of internal gas or vapours. In addition, any gaps in the enclosure wall have to designed in such a way that they will not transmit a gas explosion inside the enclosure to an explosive gas or vapours atmosphere outside it. In this study, we explained some of the most important physical mechanism of MESG(Maximum Experimental Safe Gap) that the jet of combustion products ejected through the flame gap to the external surroundings do not have an energy and temperature large enough to initiate an ignition of external gas or vapours. We measured the MESG and maximum explosion pressure of ternary gas mixtures(propane-acetylene-air) by the test method and procedure of IEC 60079-20-1:2010. As a result, the composition of propane gas that has lower explosive power than acetylene gas in the ternary gas mixtures makes greater effects on MESG and explosion pressure.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test (수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구)

  • Soh, Mun-Gie;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.

A Study on Secondary Students' Perceptions and Self-Efficacy of the Performance Assessments in the Science Subject (과학과 수행평가에 관한 중등학생의 인식 및 자아효능감 조사)

  • Hong, Jung-Lim;Choi, Eun-Kyung
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.2
    • /
    • pp.230-239
    • /
    • 2002
  • This study was performed to analyze the secondary students' perceptions and self-efficacy of performance assessments in the science subject. The data was obtained from 236 middle school students and 222 high school students in seoul. The students had generally proper understanding about characteristics of performance assessment which include purposes of assessment and differences from other conventional achievement assessments. They responded that the performance assessments were not useful in their science learning and developing their potential abilities. They were not satisfied with reliability and validity of the performance assessments. The middle school students more positively responded than high school students regarding the reliability of the scoring system and the originality of the evaluating materials. The female students more positively thought than males about the reliability of assessment and the usefulness for learning science. The students' self-efficacy level of performance assessment were not low in comparison with another existing assessments. They had high level of self-efficacy in understanding of experimental procedures, and utilizing of experimental apparatuses, but had low level of self-efficacy in understanding purposes of experiments or issues of discussions, processing of experimental results, answering of problems in experimental discussions. The female students' self-efficacy of performance assessment were higher than male students'. There was statistically correlated with females' scores and their level of self-efficacy of performance assessment.