• 제목/요약/키워드: experimental apparatus

검색결과 1,175건 처리시간 0.024초

브레이크 라이닝 패드의 마찰 진동 (Friction-Induced Vibration of Brake Lining Pad)

  • 최연선;정성균
    • 한국자동차공학회논문집
    • /
    • 제2권5호
    • /
    • pp.93-100
    • /
    • 1994
  • Friction-induced vibration characteristics of automotive brake lining pad are investigated on the basis of experimental observations from a pin-on-disk type friction-induced vibration experimental apparatus. The measured responses of the experimental apparatus show limit cycles of quasi-harmonics type and beat phenomena due to the velocity dependence of friction force. To deduce the friction coefficient vs. relative velocity Lienard method is adopted with least square fit. It shows Scurve which characterizes a quasi-harmonic vibration. The calculation of amplitudes and friquencies of the limit cycles is done using slowly changing phase and amplitude method. The theoretical and numerical results show fairly good agreements with those of experiments.

  • PDF

사고전류 인가 시 초전도선재의 상전도-초전도 접합부가 통전전류와 ?치저항에 미치는 영향 (Effect on the Transport Current and Quench Resistance of the HTS Wire with Normal-Superconducting Junction During the Fault Current Applying)

  • 홍공현;두호익;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.625-629
    • /
    • 2015
  • The second-generation HTS wire its YBCO coated conductor is widely used in the superconducting power apparatus. The YBCO coated conductor uses the normal-superconducting junction to increase the transport capacity of superconducting power apparatus when it is applied. The normal-superconducting junction can be a cause of reducing the stability of the superconducting power apparatus when a fault current is applied. Thus, in this study we have conducted the effect analysing normal-superconducting junction for the fault current using transport current and quench resistance. From the experimental results when a fault current is applied, the effect on the normal-superconducting junction is reduced the larger the amplitude of the fault current and is helpful to maintain the thermal stability of the HTS wire.

로터리 압축기용 Short-Cycle 신뢰성 시험장치 제안 (Suggestion of Test Apparatus for Reliability Evaluation of a Rotary Compressor with a Short-Cycle)

  • 이태구;이상재;김현우;김상현;이재헌;유호선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.584-589
    • /
    • 2006
  • In this paper, a test apparatus for reliability evaluation of a rotary compressor has been suggested with a short-cycle concept. $CO_2$ refrigerant is adopted for this cycle to avoid phase change during cycle operation. Evaporator is not necessary in short-cycle. Utilizing a short-cycle, the test apparatus was built on the purpose of evaluating the reliability of each rotary compressor on the conveyer belt of the factory. The primary validation of the test apparatus is discussed by analyzing the experimental heat balance data. Additional validation was performed through the overload continuous operation test where the wear rate of the $CO_2$ short-cycle was found to similar to that of the R22 normal-cycle. The reliability evaluation test apparatus with a short-cycle in present investigation was found simple and efficient in the view of reducing sample numbers, costs, and test time in analyzing the reliability of rotary compressors.

  • PDF

Development of a PLD heater for continuous deposition and growth of superconducting layer

  • Jeongtae Kim;Insung Park;Gwantae Kim;Taekyu Kim;Hongsoo Ha
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.14-18
    • /
    • 2023
  • Superconducting layers deposited on the metal substrate using the pulsed laser deposition process (PLD) play a crucial role in exploring new applications of superconducting wires and enhancing the performance of superconducting devices. In order to improve the superconducting property and increase the throughput of superconducting wire fabricated by pulsed laser deposition, high temperature heating device is needed that provides high temperature stability and strong durability in high oxygen partial pressure environments while minimizing performance degradation caused by surface contamination. In this study, new heating device have been developed for PLD process that deposit and growth the superconducting material continuously on substrate using reel-to-reel transportation apparatus. New heating device is designed and fabricated using iron-chromium-aluminum wire and alumina tube as a heating element and sheath materials, respectively. Heating temperature of the heater was reached over 850 ℃ under 700 mTorr of oxygen partial pressure and is kept for 5 hours. The experimental results confirm the effectiveness of the developed heating device system in maintaining a stable and consistent temperature in PLD. These research findings make significant contributions to the exploration of new applications for superconducting materials and the enhancement of superconducting device performance.

피동 원자로건물 냉각계통 실험에 관한 수치적 연구 (Numerical Investigation on Experiment for Passive Containment Cooling System)

  • 하희운;서정수
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.96-104
    • /
    • 2020
  • The numerical simulations were conducted to investigate the thermal-fluid phenomena occurred inside the experimental apparatus during a PCCS, used to remove heat released in accidents from a containment of light water nuclear power plant, operation. Numerical simulations of the flow and heat transfer caused by wall condensation inside the containment simulation vessel (CSV), which equipped with 18 vertical heat exchanger tubes, were conducted using the commercial computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the wall condensation model were used for turbulence closure and wall condensation, respectively. The simulation using the actual size of the apparatus. However, rather than simulating the whole experimental apparatus in consideration of the experimental cases, calculation resources, and calculation time, the simulation model was prepared only in CSV. Selective simulation was conducted to verify the effects of non-condensable gas(NC gas) concentration, CSV internal pressure, and wall sub-cooling conditions. First, as a result of the internal flow of CSV, it was observed that downward flow due to condensation occurred surface of the vertical tube and upward flow occurred in the distant place. Natural convection occurred actively around the heat exchanger tube. Due to this rising and falling internal flow, natural circulation occurred actively around the heat exchanger tubes. Next, in order to check the performance of built-in condensation model using according to the non-condensable gas concentration, CSV internal flow and wall sub-cooling, the heat flux values were compared with the experimental results. On average, the results were underestimated with and error of about 25%. In addition, the influence of CSV internal pressure and wall sub-cooling was small, but when the condensate was highly generated due to the low non-condensable gas concentration, the error was large compared to the experimental values. This is considered to be due to the nature of the condensation model of the CFX code. However, in spite of the limitations of CFD, it is valid to use the built-in condensation model of CFD for PCCS performance prediction from a conservative perspective.

수조모델을 이용한 구조체의 전위상승에 대한 측정값과 계산값의 비교 (Comparison of Measured Data and Theoretical Results for Potential Rise of Structure Using Electrolytic Tank Model)

  • 길형준;김동우;최충석;이복희
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.72-77
    • /
    • 2006
  • 본 논문에서는 구조체의 전위상승에 대해 수조실험장치에 의한 측정값과 CDEGS 프로그램에 의한 계산값의 비교를 나타낸다. 시험전류가 구조체 모형을 통해 흐를 때, 실시간으로 수조실험장치를 이용하여 구조체의 유형에 따른 전위상승이 측정 및 분석되었고, CDEGS 프로그램에 의해 계산되었다. 구조체 모형은 160:1의 축척으로 4가지 유형에 대해 설계 및 제작되었다. 측정값과 계산값이 비교되었을 때, 유사한 분포를 나타내었으며 이를 통해 측정의 신뢰성을 얻게 되었다. 망상형 철골구조로서 전기적 케이지 방식인 구조체 모형 B에서 가장 낮은 전위상승이 발생하였으며, 전위상승 분포는 구조체에 부착된 콘크리트의 저항률 및 흡수율에 의존하는 특성을 나타내었다.

집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발 (Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen)

  • 김동회
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.557-563
    • /
    • 2022
  • 극세 공극 직물의 알레르겐 투과율을 측정하기 위해서는 극세 공극 직물의 공극을 측정하는 편리하고 적절한 실험 장치의 연구 개발이 필요하다. 본 연구에서는 중량 감소율을 측정하여 극세 공극 직물의 공극 크기를 측정하기 위한 간단하고 경제적인 실험 방범을 개발하였다. 또한, 개발된 미세 입자 투과 장치를 사용하여 다양한 직물의 공극 크기를 측정하여 알레르겐 차단 성능을 평가하였다. 본 연구에 의하면 극세 공극 직물의 공극의 크기는 중량 감소 비율을 측정함으로써 구할 수 있었다. 또한 중량 감소 비율의 값은 입자 투과 장치를 통과하는 흡입 압력이 작을수록, 흡입 시간이 길수록 큰 값을 나타났으며, 이 값으로부터 직선 삽입 방법을 통하여 실험 직물의 공극 크기를 측정 할 수 있었다. 개발된 실험 장치 및 방법은 집먼지 진드기 차단 침구에 사용되는 극세 공극 직물에 대하여 그 효과를 검증하는 품질 관리 방법의 실험 기준으로 사용될 수 있을 것으로 기대된다.

초전도 기기의 전기절연 (Electrical Insulation for Superconducting Apparatus)

  • 곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 1989
  • Some experimental studies on the dielectric strength characteristics of organic material under compressive stress associated with high magnetic fields and of liquid coolant in the presence of thermally induced bubble, which might be generated at unexpected quench of immersed-cooling superconducting devices, was performed to obtain the basic data on the electrical insulation design for superconducting apparatus. PET and liquid nitrogen were used as test mediums.

  • PDF

수열원 펌프에서의 R-22 대체냉매의 응축열전달특성에 관한 연구 (Condensing Heat Transfer Charactristics of R-22 Alternative Refrigerants on Water Sources Heat Pump)

  • 김기수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.285-293
    • /
    • 1998
  • This paper presents an experimental study on condensing heat transfer characteristics of R-22 alternative refrigerants, R-290 and R-410a on water sources heat pump. The apparatus mainly consisted of vapor pump condenser used to the test section evaporator manual expansion valve and measuring device. Test section constructed a smoothed tube of 10.07 mm ID and 12.7mm OD with a total length 6,300 mm was horizontal double pipe counterflow condenser. The refrigerants R-22, R-290 and R-410a were cooled by a coolant circulated in a surrounding annulus. Experimental range of mass velocities was changed from about 100 to 300 kg/($m^2$.s) and inlet quality 1.0 The credibility of experimental apparatus was 6 percent between heating capacity and cooling capacity added to compressor shaft power. The condensing heat transfer coefficients were increased with increasing mass velocity. However in case of R-290 they were more increasing than those of R-410a and R-22 Comparing the heat transfer coefficient between the experimental data and other's data the Cavallini-Zecchin's data was revealed to more similar prediction of author's experimental results on the average heat transfer coefficients.

  • PDF

Tag 개방식 장치를 이용한 n-Propanol+n-Decane 계의 하부인화점 측정 및 예측 (Measurement and Prediction of the Lower flash Point for n-Propanol+n-Decane System Using the Tag Open-Cup Apparatus)

  • 하동맹
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.162-168
    • /
    • 2005
  • 노말프로판올과 노말데칸의 가연성혼합물의 하부인화점을 Tag개방식 장치를 이용하여 측정하였다. 실험결과 인화점과 조성의 관계에서 혼합물 보다 낮은 인화점을 보여주었다. 노말 프로판올의 몰분율 0.71에서 $27^{\circ}C$였으며, 노말프로판올의 인화점은 $28^{\circ}C$였다. 실험 결과는 이상용액을 근거로 한 예측 값과 활동도계수 예측식인 van Laar식을 사용하여 계산된 값을 각각 비교하였다. 이상용액 개념을 이용한 예측 값은 실험 값과 차이를 보였으나, van Laar 식에 의한 예측 값은 실험 값과 일치하였으며, van Laar식에 의한 예측 값과 실험 값은 평균 $0.83^{\circ}C$차이를 보였다. 본 연구에서 제시된 방법론은 가연성물질에 대해 안전한 저장 및 취급하는 조건의 결정과 같은 화학공정 설계의 본질적 안전 설계에 적용할 수 있다.