• 제목/요약/키워드: expansion tube

Search Result 292, Processing Time 0.029 seconds

Development of Steam-Generator UT System and Experimental Verification (증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발)

  • Park, Jae-Seok;Hong, Soon-Sin;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.442-448
    • /
    • 2007
  • The ultrasonic inspection system for the expansion/transition area of steam generator tube was successfully developed. Variety of artificial flaw and real track specimen was tested using the UT system to verify the performance of the system. All artificial flaws of which through-wall depth larger than 10% was clearly detected by UT system. Measurement results of through-wall depth of flaws larger than 20% had good linearity and reproducibility with 3.27 of standard deviation. Results of real crack specimen test suggested that the detection limit of real crack strongly depends on the track morphology. A potential for measurement of PRL(percentage of remaining ligament) was recognized by the real crack specimen test.

Reexpansion Pulmonary Edema (재팽창성 폐부종 3례 보고-)

  • Oh, Duck-Jin;Lee, Young;Lim, Seung-Pyeung;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.581-584
    • /
    • 1996
  • Reexpansion pulmonary edema is a rare complication of the treatment of lung collapse secondary to pneumothordx, pleural effusion, or atelectasis but occasionally life threatening. Generally, reexpansion pulmonary edema is believed to o cur only when a chronically collapsed lung is rapidly reexpanded by evacuation or large amounts of air or fluid. This complication is heralded by tachypnea, unilateral rales, and profuse expectoration of frothy secretion within several hours of reexpansion. Increased dur- ation of pneumothorax and the use o( suction are important factors in the generation of reexpansion pulmonary edema. We had experienced 3 cases of reexpansion pulmonary edema. In the two cases the pneumothorax had been present for several days, and, after insertion of a chest tube, pulmonary edema developed unilaterally but improved with supplemental oxygen. In the third case, massive pleural effusion was present. and, after insertion of a chest tube, pulmonary edema developed unilaterally, followed by cardiac arrest. He died of pulmonary edema inspire of resuscitation.

  • PDF

Re-Expansion Pulmonary Edema Associated with Resection of Ruptured Hlediastinal Thymic Cyst -A Case Report (파열된 종격동 흉선낭종의 절제술후 동반된 재팽창성 폐부종 -1례 보고-)

  • Jo, Deok-Geun;Lee, Jong-Ho;Gwak, Mun-Seop
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1149-1153
    • /
    • 1997
  • Unilateral reexpansion pulmonary edema(RPE) is generally considered a rare complication occurring when a chronically atelectatic lung is rapidly reexpanded by tube thoracostomy or thoracentesis. It can also take place when the lung collapse is of short duration or when the lung is reexpanded without intrapleural sucti n. We experienced a case of RPE following surgical resection in mediastinal thymic cyst A 26 year old female patient suffered from long-standing atelectasis of the right lung due to a huge mediastinal cyst that was misrecognized as tuberculous pleural effusion. Empyema developed after iatrogenic rupture of mediastinal cyst by pig-tailed tube thoracostomy. We successfally managed the ruptured mediastinal thymic cyst, empyema and postoperatively developed RPE following reexpansion of the collapsed lung. The patient was treated with drugs and mechanical ventilation with positive end-expiratory pressure for RPE. The remainder of her hospital course was uneventful.

  • PDF

Spray Characteristics of Supersonic Liquid Jet by a Nozzle Geometry of Miniature High-Pressure Injection System (축소형 초고압 분사 시스템의 노즐 형상에 따른 초음속 액체 제트 분무 특성에 관한 연구)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.177-180
    • /
    • 2010
  • Two-stage light gas gun, sorted with Ballistic Range System, is used to research spray characteristics of supersonic liquid jets. When high pressure tube was pressurized to the 135 bar, diaphragm films which composed with OHP film are ruptured. Expansion gases accelerate a projectile approximately 250 m/s at the exit of pump tube. And accelerated projectile collides with liquid storage part and liquid jets were injected into supersonic conditions. Supersonic liquid jets show the multiple jets and generate shockwave at the forward region of jets. Supersonic liquid jets of speed and shockwave angle have different value at each case. Supersonic liquid jets with minimum velocities are injected with M=1.53 at the geometry condition of L/d=23.8.

  • PDF

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.

A Study on the Shear Modulus of Weathered Granite Soil by Pressuremeter Tests (공내재하시험을 이용한 화강풍화토의 전단계수 산정)

  • Kim, Jong-Soo;Lee, Kyu-Hwan;Lee, Chang-Tok;Lee, Song
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.95-106
    • /
    • 1997
  • A pressuremeter is an expandable tube which is placed in the soil, and then expanded under controlled condition against the soil. From this test a pressure expansion curve of the soil can be obtained. However soil disturbance during the test has significant influence on the results of tests. A general governing equation for pressuremeter test can be theoretically derived on the basis of the hyperbolic soil model and the cavity expansion theory. The curve fitting technique was used to establish the pressure-strain curve without disturbance of soil during testing. This interpretation makes use of both the loading and unloading portions of the test. An interpretation methodology is described and illustrated with pressuremeter test data carried out in the weathered granitic soil to estimate initial shear modulus. Standard penetration test is a very common site investigation technique in Korea. Therefore the blow counts of standard penetration test are discussed by comparing them with initial shear modulus.

  • PDF

Case Study of Moving up the Charts in K-pop : Focusing on Brave Girls' 「Rollin'」 (K-pop 음원 역주행에 대한 사례 분석 : 브레이브걸스(Brave Girls)의 「롤린(Rollin')」을 중심으로)

  • Jung, Seung-Hwan
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.5
    • /
    • pp.69-83
    • /
    • 2021
  • To understand 'Moving up the charts' as a dynamic phenomenon in the K-pop entertainment industry, this study specifically analyzed the 'Moving up the charts' of 「Rollin'」 sung by 'Brave Girls'. First, the context and process related to 「Rollin'」 were described in detail, and the performance as a sound source and business were described. Subsequently, six factors were analyzed and presented as causes for 'Moving up the charts': 'Existence of specific possible triggers', 'Attractions of content itself', 'Inflow of new male fans', 'Turning weaknesses into strengths as idol', 'Psychological empathy with stories of real group' and 'Fast response and communication of agency'. Due to the influence of 'Moving up the charts', two changes were presented: 'Expansion of popularity and interest and expansion beyond songs' and 'Forming a consumer group with high purchasing power'. Through this, this study discussed the meaning, role, and possibility of 'Moving up the charts' in the K-pop entertainment industry. In the future, it will be necessary to recognize 'Moving up the charts' in the music market as a remarkable phenomenon, and to understand the importance of new idol consumer class as well as the use of related media such as YouTube.

Re-expansion Pulmonary Edema in a patient with Secondary Spontaneous Pneumothorax Following Closed Thoracostomy: A Case Report (이차성 자연기흉 환자에게 폐쇄식 흉관삽입술로 인한 재팽창성 폐부종에 관한 증례보고)

  • Seon Woo Oh;Su Wan Kim
    • Journal of Medicine and Life Science
    • /
    • v.18 no.3
    • /
    • pp.61-65
    • /
    • 2021
  • Although re-expansion pulmonary edema (RPE) is rare (incidence rate <1%), it is associated with a mortality rate of >20%; therefore, early diagnosis and treatment are important. We report a case of RPE following chest tube insertion in a patient with spontaneous pneumothorax. We have specifically focused on the mechanism underlying RPE and the possible etiology. An 82-year-old man with a history of chronic anemia, chronic obstructive pulmonary disease, diabetes mellitus, and hypertension was referred to the emergency department for management of recurrent right-sided pneumothorax. We performed emergency closed thoracostomy for suspected tension pneumothorax, which led to stabilization of the patient's vital signs; however, he coughed up frothy pink sputum accompanied by severe right-sided chest pain 30 min postoperatively. The patient showed new-onset right pulmonary consolidation on chest radiography, as well as desaturation, tachycardia, and tachypnea and was diagnosed with RPE. He was transferred to the intensive care unit for mechanical ventilation and supportive treatment using diuretics, ionotropic agents, and prophylactic antibiotics. RPE gradually resolved, and the patient was extubated 3 days after admission. He has not experienced recurrent pneumothorax or pulmonary disease for 4 months. We emphasize the importance of RPE prevention and that aggressive ventilator care and supportive treatment can effectively treat RPE following an accurate understanding of the underlying pathogenetic mechanisms and risk factors.

Investigating the load-displacement restorative force model for steel slag self-stressing concrete-filled circular steel tubular columns

  • Feng Yu;Bo Xu;Chi Yao;Alei Dong;Yuan Fang
    • Steel and Composite Structures
    • /
    • v.49 no.6
    • /
    • pp.615-631
    • /
    • 2023
  • To investigate the seismic behavior of steel slag self-stressing concrete-filled circular steel tubular (SSSCFCST) columns, 14 specimens were designed, namely, 10 SSSCFCST columns and four ordinary steel slag (SS) concrete (SSC)-filled circular steel tubular (SSCFCST) columns. Comparative tests were conducted under low reversed cyclic loading considering various parameters, such as the axial compression ratio, diameter-thickness ratio, shear-span ratio, and expansion ratio of SSC. The failure process of the specimens was observed, and hysteretic and skeleton curves were obtained. Next, the influence of these parameters on the hysteretic behavior of the SSSCFCST columns was analyzed. The self stress of SS considerably increased the bearing capacity and ductility of the specimens. Results indicated that specimens with a shear-span ratio of 1.83 exhibited compression bending failure, whereas those with shear-span ratios of 0.91 or 1.37 exhibited drum-shaped cracking failure. However, shear-bond failure occurred in the nonloading direction. The stiffness of the falling section of the specimens decreased with increasing shear-span ratio. The hysteretic curves exhibited a weak pinch phenomenon, and their shapes evolved from a full shuttle shape to a bow shape during loading. The skeleton curves of the specimens were nearly complete, progressing through elastic, elastoplastic, and plastic stages. Based on the experimental study and considering the effects of the SSC expansion rate, shear-span ratio, diameter-thickness ratio, and axial compression ratio on the seismic behavior, a peak displacement coefficient of 0.91 was introduced through regression analysis. A simplified method for calculating load-displacement skeleton curves was proposed and loading and unloading rules for SSSCFCST columns were provided. The load-displacement restorative force model of the specimens was established. These findings can serve as a guide for further research and practical application of SSSCFCST columns.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.