• 제목/요약/키워드: expansion tube

검색결과 292건 처리시간 0.024초

플랜지 형성 액압성형시 공정변수에 따른 성형 특성 (Effect of Process Parameters on Forming Characteristics of Flange Hydroforming Process)

  • 이호진;주병돈;최민규;문영훈
    • 소성∙가공
    • /
    • 제19권2호
    • /
    • pp.113-119
    • /
    • 2010
  • Hydroforming is the technology that utilizes hydraulic pressure to form tube or sheet materials into desired shapes inside die cavities. Tube hydroforming provides a number of advantages over the conventional stamping process, including fewer secondary operations, weight reduction, assembly simplification, adaptability to forming of complex structural components and improved structural strength. In many case, hydroformed parts have to be structurally joined at some point. Therefore it is useful if the hydroformed automotive parts can be given a localized attachment flange. In this study for the numerical process design FE analysis was performed with DYNAFORM 5.5. Die parting angle and circumferential expansion ratio was optimized. With optimized condition, bulge and hydroforming experiments to form flange were performed. Forming characteristic at various pressure conditions was analyzed and optimized internal pressure condition was evaluated. The results show that flanged parts can be successfully produced by tube hydroforming process.

Research on fast cool-down of orifice pulse tube refrigerator by controlling orifice valve opening

  • Kim, Hyo-Bong;Park, Jong-Ho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, a noble method for rapid cooldown of pulse tube refrigerator (PTR) was proposed and experimentally investigated. An orifice pulse tube refrigerator generates refrigeration effect by expansion PV work at the cold-end, and its amount is affected by the orifice valve opening. There exists the optimum valve opening for maximum cooling capacity and it varies as cold-end temperature. It is verified from simulation results using isothermal model that the optimum valve opening increases as the cold-end temperature increases. In the experiments, a single stage orifice pulse tube refrigerator is fabricated and tested. The fabricated PTR shows 97.5 K of no-load temperature and 10 W at 110 K of cooling capacity with the fixed orifice valve opening. From experiments, the initial cooldown curve with four cases of valve opening control scenario are obtained. And it is experimentally verified that the initial cooldown time can be reduced through the control of orifice valve opening.

Stresses in FGM pressure tubes under non-uniform temperature distribution

  • Eraslan, Ahmet N.
    • Structural Engineering and Mechanics
    • /
    • 제26권4호
    • /
    • pp.393-408
    • /
    • 2007
  • The effects of material nonhomogeneity and nonisothermal conditions on the stress response of pressurized tubes are assessed by virtue of a computational model. The modulus of elasticity, the Poisson's ratio, the yield strength, and the coefficient of thermal expansion, are assumed to vary nonlinearly in the tube. A logarithmic temperature distribution within the tube is proposed. Under these conditions, it is shown that the stress states and the magnitudes of response variables are affected significantly by both the material nonhomogeneity and the existence of the radial temperature gradient.

HOLD EFFECT IN FINITE TORSION OF A COMPRESSIBLE ELASTIC TUBE

  • Akinola, A.P;Layeni, O.P;Ldejobi, O.A.;Umoru, L.E.
    • Journal of applied mathematics & informatics
    • /
    • 제16권1_2호
    • /
    • pp.323-336
    • /
    • 2004
  • We consider the application of complex variable method to elastic problem and investigate the nonlinear effect of finite torsion of a compressible elastic composite layer. We obtain that as a result of finite deformation approach, a tube subjected to torsion decreases in radius giving rise to a “hold effect”.

영광 #1/2 복수기 누수부 보수공사 (Yeonggwang #1/2 steam condenser leakage repair works)

  • 이상철;공창식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.117-119
    • /
    • 2003
  • Power plant efficiency and availability depend greatly on condenser performance. However, during commissioning of Yeonggwang #1/2 steam condenser sodium leakage occurred, because of tube to tubesheet only roll expanding. Therefore this report is explaining that pre-test for the shake of improvement reliable repair processes & selected sampling tube re-expansion in-situ applications.

  • PDF

Collisional Excitation using Metastable Helium Jet Produced in a Graphite Tube Nozzle

  • 최익순;하영미;이상국
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권12호
    • /
    • pp.1285-1288
    • /
    • 1997
  • The graphite tube nozzle has been developed for the generation of metastable He jet by which the nitrogen molecules initially excited in a jet with Engelking type nozzle have been further excited in a corona excited supersonic expansion. The excitation process of nitrogen molecules in the jet collision has been discussed in detail by observing the emission intensity from the vibronic emission spectra of nitrogen molecules and nitrogen molecular ions upon helium jet collision.

Simulations of fluidelastic forces and fretting wear in U-bend tube bundles of steam generators: Effect of tube-support conditions

  • Hassan, Marwan;Mohany, Atef
    • Wind and Structures
    • /
    • 제23권2호
    • /
    • pp.157-169
    • /
    • 2016
  • The structural integrity of tube bundles represents a major concern when dealing with high risk industries, such as nuclear steam generators, where the rupture of a tube or tubes will lead to the undesired mixing of the primary and secondary fluids. Flow-induced vibration is one of the major concerns that could compromise the structural integrity. The vibration is caused by fluid flow excitation. While there are several excitation mechanisms that could contribute to these vibrations, fluidelastic instability is generally regarded as the most severe. When this mechanism prevails, it could cause serious damage to tube arrays in a very short period of time. The tubes are therefore stiffened by means of supports to avoid these vibrations. To accommodate the thermal expansion of the tube, as well as to facilitate the installation of these tube bundles, clearances are allowed between the tubes and their supports. Progressive tube wear and chemical cleaning gradually increases the clearances between the tubes and their supports, which can lead to more frequent and severe tube/support impact and rubbing. These increased impacts can lead to tube damage due to fatigue and/or wear at the support locations. This paper presents simulations of a loosely supported multi-span U-bend tube subjected to turbulence and fluidelastic instability forces. The mathematical model for the loosely-supported tubes and the fluidelastic instability model is presented. The model is then utilized to simulate the nonlinear response of a U-bend tube with flat bar supports subjected to cross-flow. The effect of the support clearance as well as the support offset are investigated. Special attention is given to the tube/support interaction parameters that affect wear, such as impact and normal work rate.

자동차용 범퍼레일의 하이드로포밍 기술 연구 (A Study on the Hydroforming Technology of an Automotive Bumper Rail)

  • 손성만;이문용;이상용
    • 소성∙가공
    • /
    • 제9권6호
    • /
    • pp.561-566
    • /
    • 2000
  • Recently, the hydroforming technology has been recognized as a general technique in manufacturing industry, especially in automotive industry. Hydroforming is applied to increase strength, and to decrease weight, cost and parts. Hydroforming is based on the inflation of, for Instance, a tube, coupled with axial or radial compression and by subsequent expansion and sizing against the die wall. Expansion, axial feeding, calibration are important parameters in this process. In this paper, the effects of various parameters such as internal pressure, axial feeding and friction on hydroforming of automotive bumper rail have been considered.

  • PDF

Micro-Shock Tube 유동에 대한 실험적 연구 (Experimental Study of Micro-Shock Tube Flow)

  • 박진욱;김규완;;김희동
    • 대한기계학회논문집B
    • /
    • 제39권5호
    • /
    • pp.385-390
    • /
    • 2015
  • Micro shock tube에서 발생하는 비정상파 거동을 실험적으로 조사 하기위해 파막 실험을 수행하였다. 실험은 스테인리스 재질의 micro shock tube를 사용하였으며, 총 8개의 압력센서를 설치하여, 충격파관에서 발생하는 충격파 및 팽창파를 측정하였다. 초기 압력비는 6.3에서 30.5까지 변화시켰으며, 관의 직경은 3mm와 6mm로 하였다. 그리고 두 가지 재질의 격막을 사용하여 격막 조건을 다양하게 실험을 수행하였다. 그 결과로부터 초기 압력비 및 관 직경의 증가에 따라 관내에서 발생되는 충격파 강도는 커지며, 가장 얇은 재질의 격막 조건에서 가장 큰 충격파 강도가 발생했다. 그리고 충격파 감쇠는 관의 직경에 가장 큰 영향을 받았다.

평면 음극선관의 재생률 향상을 위한 유리재료의 열적 특성에 관한 연구 (A Study on the Thermal Properties of Glass for Effective Salvage Process of Flat Cathode-ray Tube)

  • 박상후;이부윤;김원진;허보석
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.1988-1994
    • /
    • 2001
  • The CRT(Cathode-ray Tube) of salvage is a process of separating the panel and funnel to recycle a cathode-ray tube. In this paper, the thermal properties of glass for CRT were studied to improve its recycling ratio. In the salvage process, several patterns of breakage, as called 'comer pull', were easily generated on the sealing surface of panel or funnel glass due to the residual tensile stress, which had correlations with some parameters of the manufacturing process of CRT and the initial material properties of glass. Finite element analyses and experimental approaches on the flit sealing process were carried out to obtain the major characteristic of glass related to the residual stress. From this study, it was identified that the thermal expansion coefficient of glass had much influence on the residual stress of panel glass after frit sealing process. Therefore, the optimal conditions of thermal properties for CRT glass were proposed to achieve an effective salvage process. By using these optimal conditions, the size of comer pull on the panel and funnel glass was reduced to 10% level compared with the original size, and the recycling ratio of CRT was increased in the salvage process.