• 제목/요약/키워드: expansion ratio

검색결과 1,154건 처리시간 0.036초

금속의 특성 및 금속수소화물의 팽창에 관한 수치해석 (Numerical Study on Properties of Metals and Expansion of Metal Hydrides)

  • 정영관;박규섭
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.257-265
    • /
    • 2004
  • Numerical analysis, as EAM(Embedded Atom Method), in the atomic level is necessary to analyze the relation between the hydrogen and hydrogen absorption metals. EAM established on density functional theory was developed as a new means for calculating various properties and phenomena of realistic metal systems. In this study, we had constructed the EAM program from constitutive formulae and parameters of the hydrogen, nickel and palladium for the purpose of predicting the expansion behavior on hydrogen absorbing. In result, not only the ground state properties of metals but also lattice constants and the volume expansion ratio of metal hydrides show good agreement with Daw's data and experiment data.

밸브 타이밍 지각과 과급에 의한 흡기관 분사식 수소기관의 고성능 실현 (The Realization of High Performance in a Hydrogen-Fueled Engine with External Mixture by Retarding Valve Timing and Super Charging)

  • 이광주;허상훈;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.464-470
    • /
    • 2009
  • In order to analysis the possibility of high expansion and performance without backfire in a hydrogenfueled engine using external mixture injection, combustion characteristics and performance enhancement were analyzed in terms of retarding valve timing and increasing the boosting pressure. As the results, it was found that thermal efficiency increased by retarding intake valve timing with the same level of supplied energy is over 6.6% by the effect of high expansion including effect of combustion enhancement due to supercharging. It was also shown that the achievement of high power (equal to that of a gasoline engine), low brake specific fuel consumption and low emission (NOx of less than 16 ppm) without backfire in a hydrogen-fueled engine is possible around a boosting pressure of 1.5 bar, intake valve opening time of TDC and $\Phi$=0.35 in fuel-air equivalence ratio.

자연기흉의 원인과 개흉술에 대한 임상적고찰 (A Study of Cause and Thoracotomy in Spontaneous Pneumothorax - A Report of 57 Cases -)

  • 김성수
    • Journal of Chest Surgery
    • /
    • 제22권5호
    • /
    • pp.788-793
    • /
    • 1989
  • We have observed 501 cases of spontaneous pneumothorax from January 1981 to June 1989 at the Department of Thoracic and Cardiovascular Surgery, Chonbuk National University Hospital. Of these, 57 patients have undergone thoracotomy to treat the pneumothorax after closed thoracostomy. These 57 patients were based on this retrospective clinical analysis, and the results were as follows: The ratio of male to female was 4.2:1 in male predominance and the old aged patients, over 50 years old, occupied 47.3% of all patients. Primary spontaneous pneumothorax was 19 cases and secondary spontaneous pneumothorax was 38 cases. The underlying pathology in secondary spontaneous pneumothorax was tuberculosis emphysema and chronic obstructive pulmonary disease in 35 cases. The indications of thoracotomy were persistent air leakage in 23 cases recurrent pneumothorax in 21 cases, inadequate expansion in 13 cases. Rupture of bullae or blebs were most frequent operative and pathologic findings in persistent air leakage group and recurrent pneumothorax group. In inadequate expansion group, predominant finding was destructive lung lesion. Bullectomy and/or bullae ligation was most effective procedures in 36 cases [63%] for operative management of spontaneous pneumothorax. Duration of preoperative and postoperative chest tube indwelling day was 13.35 days and 8.05 days in persistent pneumothorax group, 8.92 days and 7.77 days in recurrent pneumothorax group, 13.23 days and 10.21 days in inadequate expansion group.

  • PDF

In-plane ESPI를 이용한 고온에서 STS430의 열팽창계수 측정 (Thermal Expansion Coefficient Measurement of STS430 at High Temperature by In-plane ESPI)

  • 김경석;강기수;장호섭
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.69-74
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,00$0^{\circ}C$ . Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 80$0^{\circ}C$ . There needs to measure the data up to 80$0^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000'E In previous studies related to thermal strain analysis, the quantitative results have not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,00$0^{\circ}C$ and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow $600^{\circ}C$ however, there is some difference up to $600^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 80$0^{\circ}C$ . The reason is the phase transformation of STS430 probably begins at 80$0^{\circ}C$

CRS시험에 의한 2차압밀계수의 결정방법 제안 (A New Proposed Technique for a Secondary Consolidation Coefficient Based on the Constant Rate of Strain Test)

  • 김형주;이민선;이용주;김대우
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.113-121
    • /
    • 2004
  • 본 연구는 사전압밀재하공법에 의해 연약지반을 개량시 재하-제하-재재하와 같은 다양한 응력변화에 의한 2차압밀량을 추정하고자, 일정변형률 압밀시험기(CRS)를 응용한 일정재하시험장치(CLR)와 표준압밀시험기를 이용한 단계 재하시험(IL)에 의해 군산점토의 압밀특성을 비교 고찰하였다. 또한 CRS시험 후 임의 팽창시점에서 재재하시 유효과압밀비에 따른 2차압밀특성과 간극비-유효응력-시간관계 등을 파악하였다. 군산점토는 유효 과압밀비가 클수록 팽창량은 크고 2차압밀 침하량은 작게 발생하고 있으며, 일시에 하중 제거 후, 재하하는 경우에서 2차압밀계수 $C'_{\alpha}$ 는 완속제거시 보다 작게 평가되고, 유효 과압밀비가 1.4이상인 경우는 유사한 값을 제시하고 있다. 재재하시 발생되는 전체침하량을 기준으로 한 2차압밀계수 $C"_{\alpha}$는 경과시간에 따라 비선형적으로 증가하나 최종값은 급속제거시와 비교하여 유사한 값을 제시하고 있다. 간극비 변형속도는 재하시간이 증가할수록 유효 과압밀비에 관계없이 2개의 시험 모두 일정한 선형관계이고, 유효 과압밀비가 증가할수록 작게 나타나고 있다.고 있다.

냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount)

  • 손창효;유태근;장승일;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.

Improvement of Input Current Waveform for Soft-Switching Boost DCM Converter with Unity Power Factor

  • Taniguchi K.;Watanabe T.;Morizane T.;Kimura N.;Lee Hyun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.556-560
    • /
    • 2001
  • In this paper, a soft-switching discontinuous mode (DCM) power factor corrected (PFC) converter is analyzed by applying the double Fourier series expansion. It is found that the fundamental component and higher-order harmonics included in the input current waveform are obtained by the Fourier series expansion of the mean value of the inductor current. From the theoretical analysis, a new method removing the distortion of the input current waveform is proposed. In spite of an open loop system, the proposed method makes a great improvement of the total harmonic distortion even if the ratio of output voltage to input voltage is very low.

  • PDF

고강도 시멘트 경화체의 특성에 미치는 수용성 폴리머의 영향 (Effect of Water-Soluble Polymer on the Properties of High Strength Hardened Cement Paste)

  • 김정환;최상흘;한기성
    • 한국세라믹학회지
    • /
    • 제26권5호
    • /
    • pp.698-704
    • /
    • 1989
  • Basic investigation for the flexural strength and water stability of hardened cement pastes using ordinary portland cement with water-soluble polyer (hydroxypropyl methyl cellulose ; HPMC) was carried out with 0.2 of water cement ratio. For molding of the specimen, the paste was mixed by twin roll mill. According to increase in the content of HPMC, the setting time of cement paste was delayed and the flexural strength was increased. The maximum flexural strength of hardened cement paste with 5.0wt% of HPMC was about 330 kg/$\textrm{cm}^2$. The expansion of the hardened cement paste immersed in water was increased with the content of water soluble polymer(HPMC). Consequently, the strength and the water stability of the hardened cement pastes were remarkably reduced by the expansion of them.

  • PDF

학교시설내 노인복지시설의 복합화에 관한 연구 (A Study On Planning for Mixed-use of Elderly Welfare Facilities in School)

  • 최재영;이종국
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.77-81
    • /
    • 2009
  • The elderly population ratio of domestic is the actual condition where the countermeasure which is various for there is a possibility of saying that is already experiencing the aging society, is considered. The expansion of the elderly welfare facility of the area where is located among the rest in the situation as a matter of metropolitan area of domestic ephemerality and the price of land which the earth has, duplication operation etc. is having a problem point and the ephemerality which are various. About of composition different facility and leads with alternative and expansion and function of function and facility leads and the synergy effect which is various shows. So this study is consequently does the school facility which is located in life circle of the city center in middle of composition of the elderly welfare facility and other facility and in the object and under proposing boil the complex at the time of spatial composition blueprint with the elderly welfare facility and the school.

  • PDF

히트펌프에서 탄화수소냉매 적용에 관한 실험적 연구 (An Experimental Study on Application of Hydrocarbon Refrigerants for Heat Pump)

  • 유성연;박동성;강태석;이제묘
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1264-1269
    • /
    • 2004
  • This research describes the application of hydrocarbon refrigerants for heat pump system which is needed for fish farm. Tested refrigerants are HCFC-22 and hydrocarbon refrigerants(CARE 50 and ASR-20). CARE 50 is mixture of R-290 and R-170, and ASR-20 is mixture of R-152a, R-290 and other additives. Heat pump consist of shell and tube heat exchanger, scroll compressor, expansion valve and accumulator. Manual expansion valve is used for testing of wide range evaporating temperature. Hydrocarbon refrigerants show a good performance as an alternative for HCFC-22 in the range of evaporating temperature from $-6^{\circ}C$ to $6^{\circ}C$.

  • PDF