• Title/Summary/Keyword: existing controller

Search Result 730, Processing Time 0.029 seconds

Design of an LMI- Based H^{\infty} Servo Controller for Tandem Cold Mill (LMI 에 기초한 연속 냉간압연기의 H^{\infty} 서보 제어기 설계)

  • Kim, In-Soo;Hwang, I-Cheol;Lee, Man-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.1
    • /
    • pp.25-34
    • /
    • 2000
  • In this paper, we design a H^\infty servo controller for gauge control of tandem cold mill. To improve the performance of the AGC(Aotomatic Gauge Control) system based on the Taylor linearized model of tandem cold mill, the H^\infty servo controller is designed to satisfy robust stability, disturbance attenuation and robust tracking properties. The H^\infty servo controller problem is modified as an usual H^\infty control problem, and the solvability condition of the H^\infty servo problem depends on the solvability of the modified H^\infty control problem. Since this modified problem does not satisfied standard assumptions for the H^\infty control problem, it is solved by an LMI(Linear Matrix Inequality) technique. Consequently, the comparison between the H^\infty servo controller and the existing PID/FF(FeedForward) controller shows the usefulness of this study.

  • PDF

Steady-State Integral Proportional Integral Controller for PI Motor Speed Controllers

  • Hoo, Choon Lih;Haris, Sallehuddin Mohamed;Chung, Edwin Chin Yau;Mohamed, Nik Abdullah Nik
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.177-189
    • /
    • 2015
  • The output of the controller is said to exceed the input limits of the plant being controlled when a control system operates in a non-linear region. This process is called the windup phenomenon. The windup phenomenon is not preferable in the control system because it leads to performance degradation, such as overshoot and system instability. Many anti-windup strategies involve switching, where the integral component differently operates between the linear and the non-linear states. The range of state for the non-overshoot performance is better illustrated by the boundary integral error plane than the proportional-integral (PI) plane in windup inspection. This study proposes a PI controller with a separate closed-loop integral controller and reference value set with respect to the input command and external torque. The PI controller is compared with existing conventional proportional integral, conditional integration, tracking back calculation, and integral state prediction schemes by using ScicosLab simulations. The controller is also experimentally verified on a direct current motor under no-load and loading conditions. The proposed controller shows a promising potential with its ability to eliminate overshoot with short settling time using the decoupling mode in both conditions.

Full-Envelope Controller Switching Scheme Using Bumpless Transfer Implementation Algorithm (무충돌 전환 구현 알고리즘을 사용한 전비행영역 제어기 교체법)

  • Kim, Tae-Shin;Kwon, Oh-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.6
    • /
    • pp.574-580
    • /
    • 2008
  • This paper has proposed a controller switching scheme for full-envelope aircraft control using the bumpless transfer implementation algorithm developed recently. This switching scheme has combined by proper rules the common existing method which switches the controller according to attitude and mach number of the aircraft with an optimization method which uses the cost function relating to bump phenomenon by means of controller switching criterion. This paper exemplifies the control performance improvement via simulations applied to a high performance aircraft benchmark problem in a wide operating range to test the proposed controller switching scheme.

Design and Implementation of RAID Controller using Serial ATA Interface (Serial ATA Interface를 통한 RAID Controller 보드의 설계 및 구현)

  • Lim, Seung-Ho;Lee, Ju-Pyung;Park, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.665-668
    • /
    • 2003
  • In this paper, we have designed and implemented the RAID controller board which connects to the host computer with serial ATA interface and connects to the disks with parallel ATA interface. Serial ATA interface is proposed to overcome the design limitation of parallel ATA while enabling the storage interface to scale with the slowing media rate demands for PC platforms. Serial ATA is to replace parallel ATA with the compatibility with existing operating systems and drivers, adding performance headroom for years to come. It Moreover, serial ATA provides even faster transfer rate of 150 Mbytes/s which is larger than that of current parallel ATA. The RAID controller board designed in this paper combines up to 4 disks with parallel ATA interface, and connects to PC host computer with serial ATA interface. We have implemented RAID controller using Verilog HDL language with FPGA chip. The RAID controller supports RAID level 0 and 1 functionality. Experimently, the average read/write performance of parallel ATA interface is about 30 Mbytes/s. Therefore, when 4 parallel disks is connected to the RAID controller board, we can get almost full throughput of serial ATA protocol using the RAID level 0 configuration with 4 disks.

  • PDF

Convergence of MPLS applied SDN to Optimize IPTV Broadcast Transmission for IPv6 and IPv4 (IPv6와 IPv4 환경에서 IPTV 전송 최적화 위한 SDN을 응용한 MPLS)

  • Hwang, Seong-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.819-824
    • /
    • 2015
  • SDN (Software Defined Network) technology, hardware and network control functions should be separated independently of existing switches or routers and data transfer functions and are also refers to a separate network architecture that can develop and run. When planning a network and designed to reflect the network control function by applying the SDN may reflect the resources efficiently. In this study, one people suggest Applications SDN, which offer an absolutely necessary part of a coded program that combines the benefits of the existing IOS (Combined Benefits) applying the model to complete the Controller part through the MPLS IOS. The OpenFlow Controller is a command to the router LER(Label Edge Router), and transmits the packet in accordance with the command to the destination according to the EXP bit. To configure TCP / IP to the IOS through the optimized coding. Using the OpenFlow protocol controller transmits an encapsulation header as defined in the MPLS packet.

Study of the Usability Factors of Remote Controllers for Multifunction A/V Appliances (다기능 A/V제품 리모컨의 사용성 결정 인자에 관한 연구)

  • Yi, Sang-Sun
    • Archives of design research
    • /
    • v.18 no.2 s.60
    • /
    • pp.201-210
    • /
    • 2005
  • In order to develop a more useful and ergonomically attractive remote controller, I peformed experiments with various subjects to define factors that may obstruct the usability of remote controllers for multifunction A/V appliances. I also performed the experiments to evaluate other factors that were created to improve the usability of them, and showed that remote controllers with the improved factors are more efficient and more attractive to use. I analyzed about 40 types of remote controllers for various A/V appliances to understand impediment factors of usability. By this analysis I found the factors that affected the usability of them, and developed three types of improved remote controllers for the next version of $Play@TV^{TM}$ also set the subjects with the task of usability tests with an existing remote controller and the three newly chosen remote controllers, and those results were analyzed qualitatively and quantitatively. The results showed that the 'B type' remote controller took less time to perform the same tasks by 9.2% than the existing remote controller. I concluded that the usability factors of remote controllers - function receptivity, presentation of a tactile clue, reasonable size and weight, how to arrange the main buttons, grouping of related functions - will be useful and effective to improve the usability of A/V appliances.

  • PDF

Design of the Fuzzy Traffic Controller by the Input-Output Data Clustering (입출력 데이터 클러스터링에 의한 퍼지 교통 제어기의 설계)

  • 지연상;최완규;이성주
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.3
    • /
    • pp.241-245
    • /
    • 2001
  • The existing fuzzy traffic controllers construct the rule-base based on the intuitive knowledge and experience or the standard rule-base, but the rule-base constructed by the above methods has difficulty in representing exactly and detailedly the control knowledge of the export and the operator. Therefore, in this paper, we propose a method that can improve the performance of the fuzzy traffic control by designing the fuzzy traffic controller which represents the control knowledge more exactly. The proposed method so modifies the position and shape of the fuzzy membership function based on the input-output data clustering that the fuzzy traffic controller can represent the control knowledge more exactly. Our method use the rough control knowledge based on intuitive knowledge and experience as the evaluation function for clustering the input-output data. The fuzzy traffic controller designed by the our method could represent the control knowledge of the expert and the operator more exactly, and it outperformed the existing controller in terms of the number of passed vehicles and the wasted green-time.

  • PDF

A Study on the Improvement of Security Threat Analysis and Response Technology by IoT Layer (IoT 계층별 보안위협 분석 및 대응기술 개선 방안 연구)

  • Won, Jong-Hyuk;Hong, Jung-Wan;You, Yen-Yoo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.149-157
    • /
    • 2018
  • In this paper, we propose an attack detection technology using SDN Controller to study security threats in IoT environment. The research methodology has been developed by applying IoT security threat management technology to the IoT layer and analyzing the research trend of applied security technology. The study results show that the effectiveness of the detection method using the sampling method is studied by adding OpenFlow based SDN Controller to the network switch equipment of the existing IoT network. This method can detect the monitoring and attack of the whole network by interworking with IDS and IPS without affecting the performance of existing IoT devices. By applying such improved security threat countermeasure technology, we expect to be able to relieve anxiety of IoT security threat and increase service reliability.

A Study on the On-Line Fuzzy ULTC Controller Design Based on Multiple Load Center Points (다중 부하중심점에 기반한 온라인 퍼지 ULTC 제어기 설계에 대한 연구)

  • Ko, Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.514-521
    • /
    • 2006
  • The existing ULTC operation control strategy based on the measured data deteriorates the voltage compensation capability making the efficient corresponding to the load variation difficult by following the fixed load center point voltage. Accordingly, this paper proposes a new on-line fuzzy ULTC controller based on the designed multiple load center points which can improve the voltage compensation capability of ULTC and minimize voltage deviation by moving in real-time the load center point according to the load variation to an adequate position among the multiple load center points designed using the clustering technique. The Max-Min distance technique is adopted as the clustering technique for the decision of multiple load points from measured MTr load current and PTr voltage, and the minimum distance classifier is adopted for the decision of fuzzy output membership function. To verify the effectiveness of the proposed strategy, Visual C++ MFC-based simulation environments is developed. Finally, the superiority the proposed strategy is proved by comparing the fuzzy ULTC operation control results based on multiple load center points with the existing ULTC operation control results based on fixed load center point using the data for three day.

The Generator Excitation Control Based on the Quasi-sliding Mode Pseudo-variable Structure Control

  • Hu, Jian;Fu, Lijun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1474-1482
    • /
    • 2018
  • As an essential means of generator voltage regulation, excitation control plays an important role in controlling the stability of the power system. Therefore, the reasonable design of an excitation controller can help improve the system stability. In order to raise the robustness of the generator exciting system under outside interference and parametric perturbation and eliminate chattering in the sliding mode control, this paper presents a generator excitation control based on the quasi-sliding mode pseudo-variable structure control. A mathematical model of the synchronous generator is established by selecting its power, speed and voltage deviation as state variables. Then, according to the existing conditions of the quasi-sliding mode, a quasi-sliding mode pseudo-variable structure controller is designed, and the parameters of the controller are obtained with the method of pole configuration. Simulations show that compared with the existing methods, the proposed method is not only useful for accurate voltage regulation, but also beneficial to improving the robustness of the system at a time when perturbance happens in the system.