• Title/Summary/Keyword: exact methods

Search Result 1,939, Processing Time 0.031 seconds

A Comparative Study on Closed vs. Open Endotracheal Suctioning on the Newborn Infants Treated with Ventilator (인공호흡기 사용 신생아의 폐쇄형과 개방형 기관흡인에 관한 연구)

  • Park, Jeong-Won;Park, Yeong-Ae
    • 아동간호학회:학술대회논문집
    • /
    • 1997.11a
    • /
    • pp.61-74
    • /
    • 1997
  • Endotracheal suctioning is a routine procedure used for clearing secretions from the airway of the intubated infant. This procedure is not without complications. Endotracheal suctioning has been associated with decreases in $PaO_2$, decreases in systemic venous oxygenation, alterations in mean arterial Pressure, disturbances in cardiac rhythm and development of nosocomial pneumonia. So several endotracheal suctioning techniques have been developed to prevent these blown complications. Another method of Endotracheal suctioning eliminates the risk associated with disconnecting the infant from the ventilatior to perform the suctioning procedure. Studies examining closed endotracheal suctioning methods reported that the closed method results in less arterial oxygen saturation, and less systemic venous oxygen desaturation. However those studies have focused on adult patients, and there have been no published studies for newborn infants. The specific purpose of this study is to investigate the two methods and to make a comparison in terms of (1)variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning; (2)difference in occurrence of nosocomial infection; (3)difference in recovery time to arrive at pre-suction baseline after suctioning and in nursing time taken for the suctioning. The present study is based on the data obtained from two groups of newborn infants : one group comprises 8 infants with closed suctioning (a total of 304 suctions) among 17 infants treated with ventilator and the other group 9 infants with open method (a total of 629 suctions). The data were analyzed using the SPSS statistical program package. As the distribution test on dependent variables with the Skewnesser Shapiro Wilk test showed an asymmetric distribution, the Wilcoxon Matched-pairs Singled- Ranks test was used for the test of variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning. The difference in $SaO_2$ recovery time and nursing time was analyzed with the Mann-Whitney U-Test. The difference in physiologic consequences and occurrence of nosocomial infection between the two groups was analyzed with the Fisher's Exact Test. The results of the study are summarized as follows. For the hypothesis 1 (There would be a difference in $SaO_2$, heart rate, and respiration rate before and after suctioning between the two suctioning methods), the difference in $SaO_2$ turns out to be statistically significant (P=0.015), but heart rate and respiration rate do not procedure a notable difference (P=0.630). The hypothesis 2 (There would be a difference in rates at which a complication arises after suctioning between the two groups) does not prove to be statistically valid (P=0.246). For the hypothesis 3(There would be a difference in $SaO_2$ recovery time and nursing time between the two groups), the average $SaO_2$ recovery time after suctioning turned out to have somewhat significant difference (P=0.064), however the difference in nursing time taken for the suctioning was not statistically significant (P=0.610). The analyses indicate that the closed endotracheal suctioning is more efficient as compared with the open method, in maintaining pre-suction baseline $SaO_2$ and a rapid recovery of newborn infants. Based on these results we suggust to apply the closed method to newborn infants in the ventilation treatment. We also suggest to extend the investigation to include the comparison of suction cost taking into account the case in which a complication arises after endotracheal suctioning between the two groups.

  • PDF

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

Clinical Efficacy of Clomiphene Citrate and Letrozole Combined with Gonadotropins for Superovulation in Patients with Clomiphene-Induced Thin Endometrium (클로미펜에 얇은 자궁내막을 보이는 환자에서 성선자극호르몬 병합 과배란유도시 클로미펜과 레트로졸의 임상적 효용성)

  • Lee, Eun-Joo;Park, Hyun-Jong;Yang, Hyo-In;Lee, Kyung-Eun;Seo, Seok-Kyo;Kim, Hye-Yeon;Cho, Si-Hyun;Choi, Young-Sik;Lee, Byung-Seok;Park, Ki-Hyun;Cho, Dong-Jae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2009
  • Objective: The aim of this study was to compare the clinical efficacy of clomiphene citrate (CC) and letrozole combined with gonadotropins for controlled ovarian stimulation (COS) in patients with CC-induced thin endometrium Methods: Fifty-one intrauterine insemination cycles performed in patients who previously had a thin endometrium (<8 mm) to ovulation induction using CC were included in this study. A CC 100 mg/day (CC+gonadotropin group, n=26) or letrozole 2.5 or 5 mg/day (letrozole+gonadotropin group, n=25) was administered on day 3~7 of the menstrual cycle, combined with gonadotropins at dose 75~150 IU every other day starting on day 5~7. We compared total dose of gonadotropin used, endometrial thickness, endometrial pattern, number of follicles ${\geq}14\;mm$ on hCG day, pregnancy rate and multiple pregnancy rate between the two groups, which were statistically analyzed using Mann-Whitney U test or Fisher's exact test, where appropriate. Results: There were no significant differences in clinical characteristics such as age, duration of infertility, number of previous IUI cycles, basal serum hormone levels and cause of infertility between the two groups. In both groups, the endometrium was significantly thicker than that of previous ovulation induction cycles using CC. No significant differences were found in the total dose of gonadotropin used, day of hCG administration, the rate of triple endometrium and pregnancy rate. The number of follicles ${\geq}14\;mm$ was significantly lower ($3.7{\pm}1.7$ vs. $2.8{\pm}1.7$, p=0.03) and the endometrium on hCG day was significantly thicker ($7.7{\pm}1.5$ vs. $9.1{\pm}1.7$, p=0.001) in letrozole+gonadotropin group compared to CC+gonadotropin group. Conclusion: The clomiphene citrate and letrozole combined with gonadotropins appear to avoid the undesirable effects on the endometrium frequently seen with CC for ovulation induction. However, in terms of adequate endometrial development or optimal follicular growth, letrozole may be more beneficial than CC for gonadotropin-combined COS in patients with CC-induced thin endometrium. Further prospective randomized controlled studies in a larger scale will be necessary to confirm our findings.

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Clinical Efficacy of Erdosteine in Patients with Acute or Chronic Bronchitis -A Randomized, Double Blind, Comparative Study vs. Ambroxol- (급.만성 기관지염 환자에서 엘도스$^{(R)}$(Erdosteine)의 임상효과 -염산 암브록솔과의 무작위 이중맹검 비교시험-)

  • Kim, Seok-Chan;Lee, Sang-Hoak;Song, So-Hyang;Kim, Young-Kyoon;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1296-1307
    • /
    • 1997
  • Background : Erdosteine is a thiol derivative developed for the treatement of chronic obstructive bronchitis, including acute infective exacerbation of chronic bronchitis. Erdosteine has mucomodulating and antioxidant properties and especially exhibits excellent gastrointestinal tolerability. Methods : The study was conducted as a prospective evaluation, with 2 comparative groups orally treated with erdosteine 300mg (bid.) or ambroxol 30mg (b.i.d.) for 7 days and the design of trial was double-blind. The treatments have been assigned randomly to patients (n=80) with acute or chronic bronchitis. The primary end-point used to determine efficacy in this study was subjective symptoms including expectorating frequence, expectoration volume, expectorating difficulty, expectoration viscosity, cough intensity and dyspnea. The secondary end-points of efficacy was the result of arterial blood gas analysis and pulmonary function test. Safety was evaluated with adverse drug reactions and laboratory tests monitoring. 61 patients was included in the efficacy analysis, due to the fact that 19 patients drop-out for different reasons. The obtained values have been analyzed with paired Hest., ANOVA test., multivariate $t^2$-test, repeated measures analysis of covariance, two sample t-test, loglinear-logit model analysis, Fisher's exact test. Results : 1) There was no significant difference on demographic data and vital signs between erdosteine and ambroxol treated groups. 2) The comparison between erdosteine and ambroxol treated groups showed no significant difference in improvement of each symptom in spite of the more favorable efficacy obtained with erdosteine. No difference on the contrary was observed for arterial blood gas analysis and pulmonary function test. 3) As safety is concerned, no clinical significant changes in laboratory test and symptom were induced in erdosteine and ambroxol treated group and two patients in ambroxol treated group drop-out for adverse reactions in symptom. 4) In the evaluation of final clinical efficacy, erdosteine improved more effectively patient's overall symptoms {very good effect (11/31), good effect (12/31), moderate effect (6/31), no effect (2/31), aggravation (0/31)} than ambroxol {very good effect (6/30), good effect (14/30), moderate effect (5/30), no effect (4/30), aggravation (2/30)}. And the probability of symptomatic improvement by erdosteine compared to ambroxol was 2.5 times. (p<0.05). Conclusion : This study showed that erdosteine was clinically effective and safe drug for treatment of acute and chronic bronchitis.

  • PDF

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.