• Title/Summary/Keyword: exact

Search Result 8,044, Processing Time 0.035 seconds

Utility of Acetazolamide-Enhanced Brain Perfusion SPECT in Predicting Outcome of the Patients with Aneurysmal Subarachnoid Hemorrhage (뇌동맥류파열에 의한 지주막하 출혈환자의 예후평가에 있어서 아세타졸아미드 부하 뇌혈류 SPECT의 유용성)

  • Choi, Yun-Young;Kim, Jae-Min;Kim, Kwang-Myung;Choe, Il-Seung;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.241-250
    • /
    • 2001
  • Purpose: Vasospasm is a complication of aneurysmal subarachnoid hemorrhage (aSAH). We assessed the role of acetazolamide-enhanced brain perfusion SPECT (ACZ-SPECT) with Tc-99m ECD for predicting the prognosis of patients with aSAH. Materials and methods: Two SPECT studios (baseline with 740 MBq and ACZ-SPECT with 1480 MBq) with image subtraction were performed in 21 patients with aSAH. All patients had brain CT and angiogram. Vasoreactivity on ACZ-SPECT, perfusion defect on baseline SPECT, and vasospasm on angiogram were correlated with Hunt-Hess grading, extent of SAH (unilateral or bilateral) on CT, and clinical outcome. Vasoreactivity was considered decreased when cerebral/cerebellar uptake ratio difference from baseline SPECT to ACZ-SPECT was greater than 2SD of normal control values. Results: Decreased vasoreactivity was observed in 38% (8/21), perfusion defect in 81% (17/21), and vasospasm in 38% (8/21). The preserved vasoreactivity group showed better outcome scale (92%, 12/13) and the decreased vasoreactivity group showed poorer outcome scale (62.5%, 5/8) (p=0.014). Extensive SAH was more frequently seen in the decreased vasoreactlvlty group (87.5%, 7/8) than in the preserved vasoreactivity group (30.7%, 4/13)(p=0.017). The perfusion defect and vasospasm did not show good correlation with outcome scale, extent of SAH, and Hunt-Hess grading (p=ns). Vasoreactivity represented the patient's outcome better than the vasospasm in all of the vasoreactivity/vasospasm-mismatched cases (6 cases). Conclusions: Our data show that decreased vasoreactivity on ACZ-SPECT does not always represent vasospastic condition. But patients with decreased vasoreactivity reveal poorer outcome than patients with angiographic vasospasm do. Therefore ACZ-SPECT is a valuable, noninvasive test for predicting the prognosis of patients with aSAH.

  • PDF

Relationship Between Adenosine-Induced ST Segment Depression During $^{99m}Tc$-MIBI Scintigraphy and The Severity of Coronary Artery Disease (Adenosine 부하 $^{99m}Tc$-MIBI 심근 관류스캔도중 나타나는 ST절 하강과 관상동맥 질환의 중증도와의 관계)

  • Cho, Jung-Ah;Choi, Chung-Il;Kwak, Dong-Suk;Kim, Jeong-Gyun;Bae, Sun-Kun;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Kang, Seung-Wan;Woo, Eon-Jo;Kim, Sin-Woo;Sohn, Sang-Kyun;Chae, Shung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 1994
  • Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent coronary vasodilator with rapid onset of action, short half-life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed $^{99m}Tc$-MIBI imaging after intravenous Infusion of adenosine In 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during $^{99m}Tc$-MIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused Intravenously at a dose of 0.14mg/kg per minute lot 6minutes and $^{99m}Tc$-MIBI was injected at 3 minute. We then com-pared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased $90{\pm}19$ beats/minute in the group with ST depression compared with $80{\pm}16$ beats/minute in the group without ST depression(p<0.05). Baseline systolic blood pressure was significantly higher in the group with ST depression($152{\pm}27$ mmHg) than in the group without 57 depression($140{\pm}21$mmHg, p<0.05). Double product at baseline($10.90{\pm}2.77$ versus $9.55{\pm}2.34\;beats/minute{\times}mmHg$) and during adenosine infusion($12.72{\pm}3.89$ versus $10.83{\pm}2.98\;beats/minute{\times}mmHg$) were significantly higher in the group with ST depression(p<0.05). The incidence of anginal chest pain was also significantly higher in the group with ST depression(ST versus 29%, p<0.0001). The $^{99m}Tc$-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p<0.05). In patients with ST segment depression, there were more reversible perfusion defects than in patients without ST segment depression(83 versus 55%, p<0.05). The number of abnormal segments were significantly higher in the group with ST depression($3.05{\pm}2.01$ versus $1.51{\pm}1.45$, p<0.005). In patients with ST segment depression, there were more segments of reversible perfusion defects than in patients without segment depression($2.15{\pm}2.11$ versus $0.89{\pm}1.24$, p<0.05). There were no differences in the angiographic severity by vessel(p ; NS). We concluded that ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy with Intravenous adenosine is related to the severity of coronary artery disease.

  • PDF

Comparison of Estradiol Results according to Manufacturer (제조회사에 따른 Estradiol 결과값의 비교)

  • Kim, Dae-Woon;Shin, Hee-Jung;You, Tae-Min;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Purpose: Estradiol in the menstrual cycle and ovulation induction as an important test of currently national nuclear medicine laboratory in the normal patients and patients with infertility tests are being performed. For the diagnosis of menopause is an important test with follicle stimulating hormone (FSH) and Luteinizing hormone (LH). Currently participating in external quality control of the nation's hospitals that is 54 percent of 37 hospitals, 20 hospitals have been using A's reagent. The kit's test results are highly different from other kit comes with the test results of specimens have been found. And for the phenomenon is to study the problem. Materials and Methods: Estraiol test were referred to our hospital which results of samples as more than 100pg/ml 75 specimens measured by radioimmunoassay(RIA) test with company A company B company C company D Kit, Chemiluminescent assay (CMIA) to examine and compare to the results from april to August in 2010. Results: Kit for each manufacturing company as measured by the results obtained using the average value of the correlation coefficient (R2) and A company 0.8906 B 0.9527 C 0.9547 and D company correlation coefficient of 0.873 showed a good correlation that measuring the results of A company high concentrations when Company B Company C Company D with CMIA test concentrations measured low results that the two cases were discovered specimens. Conclusion: Most of the test results of 75 samples came up with a similar trend, but two cases were reported in the patients very differently. A company result reported higher than 700 pg/ml, while the rest of other test results report was approximately 10 pg/ml. The common point of two samples more than 50 years patients are estimated to be diagnosed with cancer in postmenopausal patients receiving treatment and levels of FSH were found to be greater than 50 mIU/ml. Did not identify the exact cause. I suggest if you are using A company kit that need to again check when Estradiol result and follicle stimulating hormone results is higher.

  • PDF

A Study of Recognition of Housewives on Wedding Food in Seoul Area (서울지역 주부들의 혼례음식에 대한 인지도 조사)

  • Lee, Mi-Young;Yoon, Sook-Ja
    • Journal of the Korean Society of Food Culture
    • /
    • v.17 no.5
    • /
    • pp.569-577
    • /
    • 2002
  • This study was carried out to survey the degree of the recognition and necessity of wedding food to include $Ph{\grave{a}}ebak$ and Ibaji foods prepared by bride's parents and sent to the bridgroom's. The participants of the survey were 293 housewives of 20 years old or more residing in Seoul area. The questionnaires used in this research consisted of 10 questions. The findings could be summarized as follows: 1. As to the degree of the recognition of $Ph{\grave{a}}ebak$ food, 55.2 percent of the participants perceive it as 'the food sent to the bridegroomvs house to be used when the newly-weds greet groom's relatives, whereas 35.8 percent regarded the practice as 'a traditional custom from the ancient times,' which is, in fact, correct and exact. As to its importance, 10.2 percent regarded $Ph{\grave{a}}ebak$ food very important, while 48.5 percent, 'important,' and 11.9 percent, 'not important.' 2. As for the items for $Ph{\grave{a}}ebak$ dishes, 77.5 percent answered their preferences for 'jujube prop-nut,' followed by 'ricecake,' 'liquor' and 'Korean cookies,' in descending order. 3. As for the meaning of Ibaji dishes, 48.2% understand them as 'a set of dishes prepared by the bride's parents to be sent to the bridegroom's'; and as for their willingness or necessity of sending the Ibaji dishes, 15.5 percent indicated that they might prepare them, whereas 78.7 percent said that they would prepare them if the situation required. On the other hand 5.8 percent did not feel the necessity. The overall result is that most females surveyed recognized the two types of food important and were inclined to prepare them when the occasion demanded.

Review and Improvement of Highway Design Consistency Evaluation Models (설계 일관성 평가 모형의 고찰과 개선방안 연구)

  • Kim, Sang-Youp;Choi, Jai-Sung;Yang, Ji-Eun;Kim, Moon-Kyum
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.63-74
    • /
    • 2006
  • It's essential to meet the expectations of drivers through reasonable road design, which makes the drivers to recognize the conditions of road sufficiently. In this case, we could say that because the roads are consistently designed, drivers can make a safe and comfortable drive. There are so many studies about the alignment design consistency methods which are previously mentioned. In this study, Firstly we categorize the studies which are concerned with the estimation of the alignment design consistency methods and then apply the method which fits for the actual condition into the practice. And we'll make a realistic method by using the data which aye collected from the National Road. The developed model in this study is the predicting model including speed($V_t$) as the variable on the upper stream 100m of the curve. This model was developed which divided to two cases in the all directions of two lanes; One case is the $R{\leq}200m$ and another case is the R>200m. In the section of the $R{\leq}200m$, this case was influenced on the road alignment(R) and($V_t$) and another section was found that is affected to the speed($V_t$) on the upper stream loom rather than the effect of road alignment(R). In the case of all directions of four lanes, however, this study is predicted divided to two sections on the 400m of R, these section have more influenced to($V_t$) than the road alignment factors. This result of the four lanes was represented to different result with the two lanes. This study will further need development of the predicting model with the higher confidence through collecting data with more the exact data, the various road alignment data and speed of the several sections on the upper stream on the curve.

  • PDF

Clinical Analysis of Patients with Abdomen or Neck-penetrating Trauma (복부와 경부 관통상 환자에 대한 임상적 고찰)

  • Noh, Ha-Ny;Kim, Kwang-Min;Park, Joon-Beom;Ryu, Hoon;Bae, Keum-Seok;Kang, Seong-Joon
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.107-112
    • /
    • 2010
  • Purpose: Recently, the change to a more complex social structure has led to an increased frequency of traumas due to violence, accident and so on. In addition, the severity of the traumas and the frequency of penetrating injuries have also increased. Traumas to cervical and abdominal areas, what are commonly seen by general surgeons, can have mild to fatal consequences because in these areas, various organs that are vital to sustaining life are located. The exact location and characteristics of the injury are vital to treating patients with the trauma to these areas. Thus, with this background in mind, we studied, compared, and analyzed clinical manifestations of patients who were admitted to Wonju Christian hospital for penetrating injuries inflicted by themselves or others. Methods: We selected and performed a retrospective study of 64 patients who had been admitted to Wonju Christian Hospital from January 2005 to December 2009 and who had cervical or abdominal penetrating injuries clearly inflicted by themselves or others. Results: There were 51 male (79.7%) and 13 female (20.3%) patients, and the number of male patients was more dominant in this study, having a sex ratio of 3.9 to 1. The range of ages was between 20 and 86 years, and mean age was 43.2 years. There were 5 self-inflicted cervical injuries, and 19 self-inflicted abdominal injuries, making the total number of self-inflicted injury 24. Cervical and abdominal injuries caused by others were found in 11 and 29 patients, respectively. The most common area involved in self-inflicted injuries to the abdomen was the epigastric area, nine cases, and the right-side zone II was the most commonly involved area. On the other hand, in injuries inflicted by others, the left upper quadrant of the abdomen was the most common site of the injury, 14 cases. In the neck, the left-side zone II was the most injured site. In cases of self-inflicted neck injury, jugular vein damage and cervical muscle damage without deep organ injury were observed in two cases each, making them the most common. In cases with abdominal injuries, seven cases had limited abdominal wall injury, making it the most common injury. The most common deep organ injury was small bowel wounds, five cases. In patients with injuries caused by others, six had cervical muscle damage, making it the most common injury found in that area. In the abdomen, small bowel injury was found to be the most common injury, being evidenced in 13 cases. In self-inflicted injuries, a statistical analysis discovered that the total duration of admission and the number of patients admitted to the intensive care unit were significantly shorter and smaller, retrospectively, than in the patient group that had injuries caused by others. No statistically significant difference was found when the injury sequels were compared between the self-inflicted-injury and the injury-inflicted-by-others groups. Conclusion: This study revealed that, in self-inflicted abdominal injuries, injuries limited to the abdominal wall were found to be the most common, and in injuries to the cervical area inflicted by others, injuries restricted to the cervical muscle were found to be the most common. As a whole, the total duration of admission and the ICU admission time were significantly shorter in cases of self-inflicted injury. Especially, in cases of self inflicted injuries, abdominal injuries generally had a limited degree of injury. Thus, in our consideration, accurate injury assessment and an ideal treatment plan are necessary to treat these patients, and minimally invasive equipment, such as laparoscope, should be used. Also, further studies that persistently utilize aggressive surgical observations, such as abdominal ultrasound and computed tomography, for patients with penetrating injuries are needed.

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF