• 제목/요약/키워드: evaporative light scattering detector

검색결과 20건 처리시간 0.019초

HPLC-ELSC를 이용한 조제분유 중 fructooligosaccharides 및 raffinose 분석 (Determination of Fructooligosaccharides and Raffinose in Infant Formula by High Performance Liquid Chromatography with Evaporative Light Scattering Detector)

  • 신만섭;박재우;조미란;송성옥;김춘선;최춘배;이승원;이기웅;장치훈;곽병만
    • 한국식품과학회지
    • /
    • 제38권6호
    • /
    • pp.725-729
    • /
    • 2006
  • 본 연구에서는 1-kestose, raffinose, nystose 및 $1^{F}-{\beta}-fructofura-nosylnystose$ 등 4종 올리고당 분석을 위하여 기울기용매가 가능 한 증기화광산란검출기를 사용하여 이동상 조성, 유속 등 최적 조건을 설정하였다. 설정한 분석조건을 이용하여 표준액을 농도별로 희석(50, 100, 200, 400, 800${\mu}g/mL$)하여 검량선을 quadratic curve로 작성한 결과 상관계수는 1-kestose(1.0000), raffinose(0.9999), nystose(1.0000), $1^{F}-{\beta}-fructofuranosylnystose$(1.0000)으로 나타났다. 또한 분석조건의 재현성을 측정하기 위하여 혼합표준액 200${\mu}g/mL$을 5회 주입한 면적 값의 RSD는 1-kestose(1.47), raffinose(8.98), nystose(0.77), $1^{F}-{\beta}-fructofuranosylnystose$(2.02)으로 나타났다. 또한 사용된 시료의 프락토올리고당의 측정된 함량 결정계수에 대한 t-검정결과 모든 표준당에 대해 상관이 유의(p<0.05)함을 알 수 있어 본 HPLC-ELSD방법에 의한 정량이 타당한 것으로 나타났다. 본 방법을 통하여 fructooligosacchrides 및 raffinose분석에 유용한 것으로 사료된다.

ELSD를 이용한 레시틴중의 포스파티딜콜린의 분석 (Determination of Phosphatidylcholine in Korea Functional Foods Containing Lecithins using HPLC with Evaporative Light-Scattering Detector (ELSD))

  • 이창희;반경녀;조태용;이주연;이영자;채갑용
    • 한국식품위생안전성학회지
    • /
    • 제20권4호
    • /
    • pp.267-271
    • /
    • 2005
  • 본 연구는 세포막의 구성성분으로서 인체의 신진대사에 관여하는 물질인 인지질을 정량하기 위하여 인지질의 주요성분인 포스파티딜콜린에 대해 HPLC/ELSD를 이용한 신속, 정확한 분석법을 확립하였다. HPLC의 조건은 silica column을 사용하고 헥산:이소프로판올:물-30:60:8을 유속 0.5 ml/min으로 포스파티딜콜린을 분리하였고 ELSD 검출기를 사용하여 nebulizer온도는 $60^{\circ}C$. drift tube온도는 $75^{\circ}C$, carrier gas 30 psi로 하여 20 min내에 분리하였으며 검량선은 250 ppm$\∼$1,000 ppm으로 하여 정량하였다. 시료의 회수율은 $80\%$이상으로 높게 나타났으며 정량한계는 0.15 ppm이였다. 또한 이 분석법을 이용하여 실제 유통되고 있는 레시틴제품(난황레시틴 2종, 대두레시틴8종)에 대해 인지질의 함량과 포스파티딜함량을 조사한 결과, 인지질의 함량은 각각 81.5$\∼$83.3$\%$, $66.0\∼88.0\%$로 나타났으며 포스파티딜콜린의 함량은 각각 74.8$\∼$ 8.6$\%$$18.7\∼62.3\%$로 난황레시틴의 함량이 높게 나타났다.

Simultaneous determination of saikosaponin derivatives in Bupleurum falcatum by HPLC-ELSD analysis using different extraction methods

  • Choi, Jungwon;Kim, Juree;Kang, Sam Sik;Lee, Sanghyun
    • Journal of Applied Biological Chemistry
    • /
    • 제64권1호
    • /
    • pp.57-61
    • /
    • 2021
  • Saikosaponin derivatives such as saikosaponins A, B1, B2, B3, B4, C, and D present in Bupleurum falcatum were analyzed by a high performance liquid chromatograph equipped with an evaporative light scattering detector, using different extraction solvents (water and 70% ethanol). The samples were injected into a YMC Pack Pro C18 column and separated using a gradient elution system with a mobile phase composed of acetonitrile and water at a flow rate of 1.1 mL/min. The content of saikosaponin derivatives was higher in 70% ethanol extract than in water extract. This study provides an efficient analytical method for determining the optimal conditions for extraction of saikosaponin derivatives, which can be used as a basis for development of functional foods and pharmaceutical products from B. falcatum.

오징어 내장의 초임계 이산화탄소 추출 잔류물로부터 인지질의 분리 (Phospholipids Isolation from Squid Viscera Residues After Supercritical Carbon Dioxide Extraction)

  • 유병욱;전병수
    • Korean Chemical Engineering Research
    • /
    • 제48권6호
    • /
    • pp.741-746
    • /
    • 2010
  • 오징어내장에서 초임계 이산화탄소를 이용한 추출잔류물에 에탄올을 이용하거나 초임계 처리를 하지 않은 오징어내장에서 다양한 유기용매를 이용하여 인지질을 추출하였다. 초임계이산화탄소 추출은 동결 건조된 오징어 내장 시료를 이용 $45^{\circ}C$ 20 MPa 조건에서 수행되었으며 무극성 지질의 추출에 사용되었다. 동결 건조된 오징어 내장은 클로로포름, 헥산, 메탄올, 에탄올을 이용해 인지질 추출을 시행하고 초임계 이산화탄소 추출을 거친 내장 시료는 에탄올 처리하여 인지질을 추출하였다. 각 인지질 추출과정에서 pH는 5.7로 고정하여 시행하였다. 각각의 인지질의 조성을 검출하기 위하여 evaporative light scattering detector(ELSD)를 이용하여 HPLC 분석을 행하였다. 포스파티딜 콜린(PC)과 포스파티딜 이노시톨(PI)은 초임계이산화탄소 잔류물을 에탄올 추출한 것에서 동결건조물을 에탄올만을 사용하여 추출한 것보다 많은 양이 검출되었다. 하지만 포스파티딜 에탄올아민(PE)과 포스파티딕 에시드(PA)의 경우 동결 건조된 오징어내장을 에탄올만을 사용하여 추출한 인지질에서 많은 양이 검출되었다. 초임계 이산화탄소 처리 후 회수된 추잔 물질에 에탄올을 사용하여 인지질 혼합물을 분리 후 분리된 인지질 혼합물에 대해 가스크로마토그래피를 이용하여 지방산을 분석한 결과 docosahexanoic acid(DHA)의 함량이 매우 높은 것을 확인하였다.

Mobile Phase Compositions for Ceramide III by Normal Phase High Performance Liquid Chromatography

  • Hong, Seung-Pyo;Lee, Chong-Ho;Kim, Se-Kyung;Yun, Hyun-Shik;Lee, Jung-Heon;Row, Kyung-Ho
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권1호
    • /
    • pp.47-51
    • /
    • 2004
  • Ceramide III was prepared by the cultivation of Saccharomyces cerevisiae. Ceramide III was partitioned from the cell extracts by solvent extraction and analyzed by Normal Phase High Performance Liquid Chromatography (NP-HPLC) using Evaporative Light Scattering Detector (ELSD). We experimentally determined the mobile phase composition to separate ceramide III with NP-HPLC. Three binary mobile phases of n-hexane/ethanol, n-hexane/lsoprophyl Alcohol(IPA) and n-hexane/n-butanol and one ternary mobile phase of n-hexane/IPA/methanol were demonstrated. For the binary mobile phase of n-hexane/ethanol, the first mobile phase composition, 95/5(v/v), was step-increased to 72/23(v/v) at 3 min. In the binary mobile phase, the retention time of ceramide III was 7.87min, while it was 4.11 min respectively in the ternary system, where the mobile phase composition of n-hexane/IPA/methanol, 85/7/8(v/v/v), was step-increased to 75/10/15(v/v/v) at 3 min. However, in the ternary mobile phase, the more peak area of ceramide III was observed.

쌀겨 추출물로부터 스핑고당지질의 분리와 구조결정 (Isolation and Characterization of Major Glycosphingolipid from Rice Bran Extract)

  • ;;강병원
    • Applied Biological Chemistry
    • /
    • 제50권1호
    • /
    • pp.72-76
    • /
    • 2007
  • 대표적인 스핑고지질인 글리코실세라미드의 생리적 기능을 조사하기 위하여 쌀겨 추출물로부터 cerebroside를 분리하였다. 정제하지 않은 글리코실세라미드를 flash system 칼럼으로 분리한 후 ELSD를 검출기로 사용하여 순상 HPLC로 정제하였다. 클로로포름 : 메탄올 : 증류수(99:11:1, v/v/v)을 용출용매로 사용하여 주요 cerebroside를 얻을 수 있었고, MALDI/TOF-MS, FAB-MS, GC, 600MHz $^1$H-NMR로 구조를 분석하였다. 구성당은 글루코오스였고 cerebroside의 구성 지방산은 2-hydroxy-arachidic산이었다. 장쇄 염기는 sphinga-4,8-dienine이었다.

누에에 함유된 1-Deoxynojirimycin의 분석을 위한 HPLC-ELSD 분석법 밸리데이션 (Development and Validation of a Unique HPLC-ELSD Method for Analysis of 1-Deoxynojirimycin Derived from Silkworms)

  • 조혜진;이설림;신명숙;이주환;이상현
    • 생약학회지
    • /
    • 제54권1호
    • /
    • pp.38-43
    • /
    • 2023
  • A simple and accurate assay was developed for the quantitative analysis of 1-deoxynojirimycin (1-DNJ) derived from the silkworm (Bombyx mori). Normal-phase high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD) and a hydrophilic interaction liquid chromatography column was used. Various parameters were applied to optimize the analysis method. The limits of detection and quantification of 1-DNJ were 2.97 × 10-3 and 9.00 × 10-3 mg/mL, respectively. The calibration curve showed good linearity results. The concentration range and the r2 value were 0.0625-1.0 mg/mL and 0.9997, respectively. The accuracy test demonstrated a significantly high recovery rate (89.95-103.22%). The relative standard deviation was ≤ 1.00%. Thus, a method for the accurate identification and quantitative analysis of 1-DNJ in silkworms was developed. Moreover, in this procedure, the process of derivatization of 1-DNJ, which was required in previous experiments, could be eliminated. This technique may be actively utilized for the development of pharmaceuticals and health functional foods using 1-DNJ.

Simultaneous Determination of Triterpenoid Saponins from Pulsatilla koreana using High Performance Liquid Chromatography Coupled with a Charged Aerosol Detector (HPLC-CAD)

  • Yeom, Hye-Sun;Suh, Joon-Hyuk;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1159-1164
    • /
    • 2010
  • Several triterpenoid saponins from root of Pulsatilla koreana Nakai (Ranunculaceae) were studied and their biological activities were reported. It is difficult to analyze triterpenoid saponins using HPLC-UV due to the lack of chromophores. So, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we developed and validated a novel method of high performance liquid chromatography coupled with a charged aerosol detector for the simultaneous determination of four triterpenoid saponins: pulsatilloside E, pulsatilla saponin H, anemoside B4 and cussosaponin C. Analytes were separated by the Supelco Ascentis$^{(R)}$ Express C18 column (4.6 mm ${\times}$ 150 mm, 2.7 ${\mu}m$) with gradient elution of methanol and water at a flow rate of 0.8 mL/min at $30^{\circ}C$. We examined various factors that could affect the sensitivity of the detectors, including various concentrations of additives, the pH of the mobile phase, and the CAD range. Linear calibration curves were obtained within the concentration ranges of 2 - 200 ${\mu}g$/mL for pulsatilloside E, anemoside $B_4$ and cussosaponin C, and 5 - 500 ${\mu}g$/mL for pulsatilla saponin H with correlation coefficient ($R^2$) greater than 0.995. The limit of detection (LOD) and quantification (LOQ) were 0.04 - 0.2 and 2 - 5 ${\mu}g$/mL, respectively. The validity of the developed HPLC-CAD method was confirmed by satisfactory values of linearity, intra- and inter-day accuracy and precision. This method could be successfully applied to quality evaluation, quality control and monitoring of Pulsatilla koreana.

HPLC-ELSD법에 의한 길경의 platycodin D 정량분석 (Quantitative Analysis of Platycodin D from Platycodon grandiflorum by HPLC-ELSD)

  • 김금숙;김현태;성재덕;박희생;김수동
    • 한국약용작물학회지
    • /
    • 제10권3호
    • /
    • pp.200-205
    • /
    • 2002
  • 길경의 부탄올 분획으로부터 지표성분을 분리, 정제하기 위해 $SiO_2$ 컬럼크마토그래피를 실시한 결과 1종(화합물 1)의 단일 물질을 순수 분리하였으며 화합물 1의 구조는 $^1H$, $^{13}C$ NMR 등 분광학적 관측 결과 platycodin D로 확인되었다. Platycodin D의 HPLC 정량법을 검토한 결과, 검출기는 증기화광산란검출기(ELSD)를, 컬럼은 역상컬럼을 사용하여 길경 MeOH 추출액으로부터 효율적인 지표성분 정량이 가능하였다. 추출조건을 재검토한 결과 환류추출보다는 초음파 추출이 더 효율적이었으며 추출용매로는 80% MeOH이 다른 용매조건보다 추출효율이 우수하였다. 건조조건의 검토에서는 platycodin D의 함량이 양건이나 양건과 건조기 혼용건조 보다 건조기 단독 건조시 더 높았으며 특히 $60^{\circ}C$ 열풍건조에서 그함량이 0.083%로서 가장 높았다. 묽은 에탄올 엑스 함량도 건조기만을 이용한 열풍건조가 양건과 건조기 열풍건조를 혼용한 방법보다 4% 정도 더 높았다.

Discrimination of Ginseng Habitat by Using Instrumental Analysis Techniques

  • Sohn H. J.;Lee S. K.;Cho B. G.;Kim S. J.;Lee N. Y.;Choi D. S.;Jeong M. S.;Bae H. R.;Yang J. W.
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 2002년도 학술대회지
    • /
    • pp.238-252
    • /
    • 2002
  • In order to screen out indicators for the discrimination of ginseng habitat, some physical and chemical characteristics of Korean red ginsengs (94 kinds) and Chinese red ginsengs (50 kinds) were analyzed by using a rheometer, an electronic nose system, a combined technique of solid phase micro-extraction (SPME) and gas chromatograph equipped with an electron capture detector (GC/ECD), an X-ray fluorescence spectrometer (XRF), an inductively coupled plasma mass spectrometer (ICP/MS), a near infrared spectrometer (NIRs) and high performance liquid chromatography equipped with evaporative light scattering detector (HPLC/ELSD). The results are summarized as follows: (i) The rhizome strengths of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. (ii) The electronic nose patterns of Korean red ginsengs were significantly different from those of Chinese red ginsengs. (iii) Some unidentified peaks were detected not in the headspace of Korean red ginsengs but in the headspace of Chinese red ginsengs when the headspace volatiles prepared by the SPME technique were analyzed by GC/ECD. (iv) Either the content ratios of K to Ca or Mn to Fe were significantly different between Korean red ginsengs and Chinese red ginsengs. (v) The reflectance ratios of NIRs wavenumbers such as $904\;cm^{-1}\;to\;1088\;cm^{-1}$ for Korean red ginsengs were significantly different from those for Chinese red ginsengs. (vi) The content ratios of ginsenoside-Rg to ginsenoside-Re of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. These results indicate that the rhizome strength, the electronic nose pattern, the occurrence of ECD-sensitive headspace volatile components, the content ratios of K to Ca and Mn to Fe, the NIRs pattern and the content ratio of ginsenoside-Rg to -Re may be indicators for the discrimination of ginseng habitat.

  • PDF