• Title/Summary/Keyword: evaporation characteristics

Search Result 926, Processing Time 0.03 seconds

Examination of Factors Influencing Urban Higher Temperature using E-GIS DB (E-GIS DB를 활용한 도시 고온화 영향인자 검토)

  • Kim, Keum-Ji;Yoko, Kamata;Lee, Jung-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.44-49
    • /
    • 2009
  • In this study, we performed urrban climate simulation how both the factor of environmental land and artificial factors influence on the formation of urban temperature. With deducing quantitative data, this study could get more accurate results of the urban temperature using urban climate simulation system. In the case of natural land cover, it appeared that there are effects on the lowering temperature and the lower temperature rate appeared in the water land cover on the whole. This is considered as temperature in water land was low because of the characteristics of water land having evaporation latent heat was high and convective sensible heat was low. In case of building which has building coverage ratio, 5% with 10 floors and building coverage ratio, 15 % with 6 floors, it appears that the temperature in the water land is $33.6^{\circ}C$. In case of building coverage ratio 5%, temperature dropped when buildings has more than 4 stories. This is regarded as the size of building is bigger, the temperature dropped in relatively because of the fluctuation of the rate of solar heat from the land. At the present time, the urban temperature are higher because of various artificial factors in the city. With these results, this study supposed to be a basies of the future studies for considering both the composition of building coverate ratio and floor plan.

  • PDF

An Organic Electrophosphorescent Device Driven by All-Organic Thin-Film Transistor using Polymeric Gate Insulator

  • Pyo, S.W.;Shim, J.H.;Kim, Y.K.
    • Journal of Information Display
    • /
    • v.4 no.2
    • /
    • pp.1-6
    • /
    • 2003
  • In this paper, we demonstrate that the organic electrophosphorescent device is driven by the organic thin film transistor with spin-coated photoacryl gate insulator. It was found that electrical output characteristics in our organic thin film transistors using the staggered-inverted top-contact structure showed the non-saturated slope in the saturation region and the sub-threshold nonlinearity in the triode region, where we obtained the maximum power luminance that was about 90 $cd/m^2$. Field effect mobility, threshold voltage, and on-off current ratio in 0.45 ${\mu}m$ thick gate dielectric layer were 0.17 $cm^2/Vs$, -7 V, and $10^6$ , respectively. In order to form polyimide as a gate insulator, vapor deposition polymerization process was also introduced instead of spin-coating process, where polyimide film was co-deposited by high-vacuum thermal evaporation from 4,4'-oxydiphthalic anhydride (ODPA) and 4,4'-oxydianiline (ODA) and cured at 150${\sqsubset}$for 1hr. It was also found that field effect mobility, threshold voltage, on-off current ratio, and sub-threshold slope with 0.45 ${\mu}m$ thick gate dielectric films were 0.134 $cm^2/Vs$, -7 V, and $10^6$ A/A, and 1 V/decade, respectively.

Fabrication and Characteristics of $CuInS_2$ thin films produced by Vacuum Evaporation (진공증착에 의해 제조된 $CuInS_2$ 박막의 제작 및 특성)

  • Yang, Hyeon-Hun;Kim, Young-Jun;So, Soon-Youl;Jeong, Woon-Jo;Park, Gye-Choon;Lee, Jin;Chung, Hae-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.68-70
    • /
    • 2006
  • $CuInS_2$ thin films were synthesized by sulpurization of Cu/In Stacked elemental layer deposited onto glass Substrates by vacuum furance annealing at temperature 200[$^{\circ}C$]. And structural and electrical properties were measured in order to certify optimum conditions for growth of the ternary compound semiconductor $CuInS_2$ thin films with non-stoichiometry composition. $CuInS_2$ thin film was well made at the heat treatment 200 [$^{\circ}C$] of SLG/Cu/In/S stacked elemental layer which was prepared by thermal evaporator, and chemical composition of the thin film was analyzed nearly as the proportion of 1:1:2. Physical properties of the thin film were investigated at various fabrication conditions substrate temperature, annealing and temperature, annealing time by XRD, FE-SEM and hall measurement system. At the same time, carrier concentration, hall mobility and resistivity of the thin films was $9.10568{\times}10^{17}[cm^{-3}]$, $312.502[cm^2/V{\cdot}s]$ and $2.36{\times}10^{-2}[{\Omega}{\cdot}cm]$, respectively.

  • PDF

TEM Study on the Growth Characteristics of Self-Assembled InAs/GaAs Quantum Dots

  • Kim, Hyung-Seok;Suh, Ju-Hyung;Park, Chan-Gyung;Lee, Sang-Jun;Noh, Sam-Gyu;Song, Jin-Dong;Park, Yong-Ju;Lee, Jung-Il
    • Applied Microscopy
    • /
    • v.36 no.spc1
    • /
    • pp.35-40
    • /
    • 2006
  • Self-assembled InAs/GaAs quantum dots (QDs) were grown by the atomic layer epitaxy (ALE) and molecular beam epitaxy (MBE) techniques, The structure and the thermal stability of QDs have been studied by high resolution electron microscopy with in-situ heating experiment capability, The ALE and MBE QDs were found to form a hemispherical structure with side facets in the early stage of growth, Upon capping by GaAs layer, however, the apex of QDs changed to a flat one. The ALE QDs have larger size and more regular shape than those of MBE QDs. The QDs collapse due to elevated temperature was observed directly in atomic scale, In situ heating experiment within TEM revealed that the uncapped QDs remained stable up to $580^{\circ}C$, However, at temperature above $600^{\circ}C$, the QDs collapsed due to the diffusion and evaporation of In and As from the QDs, The density of the QDs decreased abruptly by this collapse and most of them disappeared at above $600^{\circ}C$.

A Study on Hydrochemistry Characteristics of Groundwater and Surface water near a Petroleum Contaminated area (유류오염지 주변 지하수와 지표수의 수화학적인 특성 연구)

  • Lim, Hong-Gyun;Lee, Jin-Yong;Park, Youngyun;Park, Yu-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.5
    • /
    • pp.10-19
    • /
    • 2012
  • The aim of this study was to examine chemical and isotopic compositions of groundwater and lake water near an area contaminated by petroleum and to evaluate influence of petroleum on them during the period from March to August 2011. In dry season, $Ca^{2+}$ and $SO{_4}^{2-}$ were dominant in the groundwater and lake water and $Ca^{2+}$ and $HCO{_3}^-$ were significant in wet season. ${\delta}^{18}O$ and ${\delta}D$ of the groundwater and lake water were plotted near LMWL (${\delta}D=8.06{\delta}^{18}O+12.5$). ${\delta}^{18}O$ and ${\delta}D$ of the lake water did not show seasonal variation. However, ${\delta}^{18}O$ and ${\delta}D$ of the groundwater were enriched in wet season compared with those in dry season because of influence of small ponds around wells where evaporation losses were slightly experienced. Redox condition of most lake water was oxidation environment in contact with the atmosphere during the study period. However, redox condition of groundwater was transitional environment in dry season and oxidation environment in wet season because of influence of contaminant such as petroleum. In some groundwater, the concentrations of $NO{_3}^-$ in some groundwater were less than 1 mg/L because of denitrification. Also, $NO{_3}^-$ showed positive correlation with $SO{_4}^{2-}$ and weak negative correlation with $HCO{_3}^-$, because of influence of denitrification.

Effect of Vapor-dam Treatment on the Air Circulating oven Drying Characteristics of Bamboo Tubes (수증기댐 처리가 통죽(筒竹)의 송풍오븐건조 특성에 미치는 영향)

  • Lee, Nam-Ho;Jung, Hee-Suk;Hayashi, Kazuo;Li, Cheng-Yuan;Zhao, Xue-Feng;Hwang, Ui-Do
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.11-16
    • /
    • 2007
  • This study was carried out to investigate the effect of Vapor-dam treatment on drying drying rates, prevention of checks and V-shaped split during air circulating oven drying bamboo (Phyllostachys pubescens Mazel et Z) tube. It was shown that the drying time from green to around 7~8 % of moisture content was required less as drying schedule was more severe, and distinctly dominated by the drying rate during the initial drying stage. Area shrinkages in cross section and thickness shrinkages measured during air circulating oven drying test were very large. Surface checks and V-shaped splits were occurred in untreated samples just after the beginning of drying, while sixty seven percentages of all the Vapor-dam treated samples could be produced without drying defects. The V-shaped splits occurred in the Vapor-dam treated samples were influenced more by the sealing of the vapor evaporation through the cross section than drying schedule.

Preparation of Polymer-Metal Complexed Membranes using Ethylcellulose and Metal salts, and Their Characteristics of Gas Separation. (Ethylcellulose와 금속염을 이용한 고분자-금속 착체막의 제조 및 기체투과특성)

  • 변홍식;서성호;박병규;홍병표;백승욱;박영규
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.200-209
    • /
    • 2003
  • Polymer-metal complexed membranes were prepared by solvent evaporation method using ethylcellulose, platinum(II)acetylacetonate, and rhodium(III)acetylacetonate. The various composition of metal salt(0.3-4.0 wt%) were employed to obtain the optimum performance of final membrane. EC-metal complexed membranes were characterized by FTIR and scanning electron microscopy(SEM) to observe the morphology and the performance of oxygen, nitrogen, carbon dioxide, and methane gases was tested. It was shown that the metal salts enhanced the permeability of all gases without decrease of selectivity. However, it was found that Pt had more effects on the permeability of oxygen and nitrogen gases while Rh had more effects on the permeability of carbon dioxide and methane gases. EC-Pt complexed membrane(Pt 1.0 wt%) even showed the enhanced selectivity of oxygen/nitrogen(37%) due to the affinity characteristic of Pt to oxygen.

Fabrication and performance evaluation of ultraviolet photodetector based on organic /inorganic heterojunction

  • Abdel-Khalek, H.;El-Samahi, M.I.;Salam, Mohamed Abd-El;El-Mahalawy, Ahmed M.
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1496-1506
    • /
    • 2018
  • Organic/inorganic ultraviolet photodetector was fabricated using thermal evaporation technique. Organic/inorganic heterojunction based on thermally evaporated copper (II) acetylacetonate thin film of thickness 200 nm deposited on an n-type silicon substrate is introduced. I-V characteristics of the fabricated heterojunction were investigated under UV illumination of intensity $65mW/cm^2$. The diode parameters such as ideality factor, n, barrier height, ${\Phi}_B$, and reverse saturation current, $I_s$, were determined using thermionic emission theory. The series resistance of the fabricated diode was determined using modified Nord's method. The estimated values of series resistance and barrier height of the diode were about $0.33K{\Omega}$ and 0.72 eV, respectively. The fabricated photodetector exhibited a responsivity and specific detectivity about 9 mA/W and $4.6{\times}10^9$ Jones, respectively. The response behavior of the fabricated photodetector was analyzed through ON-OFF switching behavior. The estimated values of rise and fall time of the present architecture under UV illumination were about 199 ms and 154 ms, respectively. Finally, enhancing the photoresponsivity of the fabricated photodetector, post-deposition plasma treatment process was employed. A remarkable modification of the device performance was noticed as a result of plasma treatment. These modifications are representative in a decrease of series resistance and an increase of photoresponsivity and specific detectivity. The process of plasma treatment achieved an increment of external quantum efficiency from 5.53% to 8.34% at -3.5 V under UV illumination.

Controlling Factors of Open-Loop Combustion Response to Acoustic Pressures in Liquid Propellant Rocket Engine (강한 압력파동에 구속된 액체 추진제 연소응답의 지배인자)

  • Yoon Woongsup;Lee Gilyong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.267-273
    • /
    • 2004
  • This paper targets to define controlling factors of pressure-coupled combustion response and estimate their effects on droplet evaporation process. Dynamic characteristics of hydrocarbon propellant vaporization perturbed by acoustic pressure are numerically simulated and analyzed. 1-D droplet model including phase equilibrium between two phases is applied and acoustic wave is expressed by harmonic function. Effects of various design factors and acoustic pressure on combustion response are investigated with parametric studies. Results show that driving frequency of acoustic perturbation and ambient pressure have important roles in determining magnitude and phase of combustion response. On the other hand, other parameters such as gas temperature, initial droplet size and temperature, and amplitude of acoustic wave cause only minor changes to magnitude of combustion response. Resultant changes in phase of heat of vaporization and thermal wave in droplet highly influence magnitude and phase of combustion response.

  • PDF

Characteristics of Energy Consumption for a Household Refrigerator under Influence of Non-condensable Gases (가정용 냉장고의 불응축 가스량에 따른 소비 전력 특성)

  • Kim, Doo-Hyun;Hwang, Yu-Jin;Park, Jae-Hong;Chung, Seong-Ir;Jeong, Young-Man;Ku, Bon-Cheol;Lee, Jae-Keun;Ahn, Young-Chull;Bang, Sun-Wook;Kim, Seok-Ro
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.381-387
    • /
    • 2008
  • The presence of non-condensable gases as an additional thermal resistance inside a refrigerating circuit has been found for a general refrigerator, The effect of non-condensable gases was varied by controlling the injection amount of dry air into the refrigerating circuit to increase a thermal resistance. Energy consumption tests for the refrigerator were conducted under the various amounts of non-condensable gases. The tested refrigerating circuit was the household refrigerator. As the molar fraction of non-condensable gases was increased from 0% to 1.46%, the amount of energy consumption was found to increase up to 25%. The increase of the amount of non-condensable gases in refrigerating circuit was found to result in increasing the condensation temperature at the condenser and decreasing the evaporation temperature at the evaporator, which were presumably caused by the low specific heat and increased partial pressure of non-condensable gas.