• Title/Summary/Keyword: evaluation procedure

Search Result 2,461, Processing Time 0.035 seconds

The Survey on Actual Condition Depending on Type of Degraded area and Suggestion for Restoration Species Based on Vegetation Information in the Mt. Jirisan Section of Baekdudaegan (식생정보에 기초한 백두대간 지리산권역 내 훼손지 유형별 실태조사)

  • Lee, Hye-Jeong;Kim, Ju-Young;Nam, Kyeong-Bae;An, Ji-Hong
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.6
    • /
    • pp.558-572
    • /
    • 2020
  • The purpose of this study was to classify the types of degraded areas of Mt. Jirisan section in Baekdudaegan and survey the actual condition of each damage type to use it as basic data for the direction of the restoration of damaged areas according to damage type based on the vegetation information of reference ecosystem. The analysis of the Mt. Jirisan section's actual degraded conditions showed that the total number of patches of degraded areas was 57, and the number of patches and size of degraded areas was higher at the low average altitude and gentle slope. Grasslands (deserted lands) and cultivated areas accounted for a high portion of the damage types, indicating that agricultural land use was a major damage factor. The survey on the conditions of 14 degraded areas showed that the types of damage were classified into the grassland, cultivated area, restoration area, logged-off land, and bare ground. The analysis of the degree of disturbance (the ratio of annual and biennial herb, urbanized index, and disturbance index) by each type showed that the simple single-layer vegetation structure mostly composed of the herbaceous and the degree of disturbance were high in the grassland and cultivated land. The double-layer vegetation structure appeared in the restoration area where the pine seedlings were planted, and the inflow of naturalized plants was especially high compared to other degraded areas due to disturbances caused by the restoration project and the nearby hiking trails. Although the inflow of naturalized plants was low because of high altitude in bare ground, the proportion of annual and biennial herb was high, indicating that all surveyed degraded areas were in early succession stages. The stand ordination by type of damage showed the restoration area on the I-axis, cultivated area, grassland, logged-off land, and bare ground in that order, indicating the arrangement by the damage type. Moreover, the stand ordination of the degraded areas and reference ecosystem based on floristic variation showed a clear difference in species composition. This study diagnosed the status of each damage type based on the reference ecosystem information according to the ecological restoration procedure and confirmed the difference in species composition between the diagnosis result and the reference ecosystem. These findings can be useful basic data for establishing the restoration goal and direction in the future.

A study on the manufacturing method and usefulness of Bolus-helmet used for malignant scalp tumor patients (악성두피종양환자에게 사용되는 보루스헬멧(Bolus-helmet)의 제작방법 및 유용성에 관한 연구)

  • Lee, joung jin;Moon, jae hee;Kim, hee sung;Kim, koon joo;Seo, jung min;Choi, jae hoon;Kim, sung gi;Jang, in gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.15-24
    • /
    • 2021
  • This study is about the introduction and usefulness evaluation of the manufacturing method of the bolus-helmet. Helmet-production for the treatment of scalp tumor patients has been tried and will continue in many creative and various ways. However, Most of the research data did not significantly reduce the psychological burden and physical and physical discomfort that the patient had to bear due to the time and economic cost required for the production of the helmet, the convenience of production, and the complexity of the process. In addition, recently, studies using more advanced technologies and equipment such as 3D-printer technology, which are being studied as a way to increase the treatment effect, are being introduced, but the time, economic cost, and psychological and physical burden are still the sole responsibility of the patient. Isn't it getting worse? The reality is that the thoughts of concern cannot be erased. Therefore, by maintaining the physical properties of the bolus and manufacturing a helmet without incurring additional costs, the physical and physical discomfort aggravated to the patient was reduced and the procedure and time for helmet manufacturing were minimized. In this way, it was possible to reduce the time, economic cost, and physical discomfort required for the production of the helmet, and it was also possible to minimize the psychological burden of the patient, although it is invisible. Additionally, in evaluating the usefulness of helmets, we are able to continuously seek and develop ways to reduce the air-gap interval, and as a result, we will be able to introduce a method to keep it within 2.0mm along with the manufacturing method through this study. I feel very welcome. Finally, I hope that anyone working in the Department of Radiation Oncology will be able to easily manufacture the helmet required for radiation therapy using a bolus through the guide-line on helmet manufacturing provided by this institute. I hope and hope that if you have any questions or inquiries that arise during the production process, please feel free to contact us through the researcher's e-mail or mobile phone at any time.

Development of Elite Lines with Improved Eating Quality Using RIL Population Derived from the Korean Weedy Rice, Wandoaengmi6 (국내 잡초벼(완도앵미6) 유래 RILs 집단의 식미 관련 특성분석 및 우량계통 선발)

  • Kim, Suk-Man;Park, Seul-Gi;Park, Hyun-Su;Baek, Man-Kee;Jeong, Jong-Min;Cho, Young-Chan;Suh, Jung-Pil;Lee, Keon-Mi;Lee, Chang-Min;Kim, Choon-Song
    • Journal of the Korean Society of International Agriculture
    • /
    • v.31 no.4
    • /
    • pp.428-436
    • /
    • 2019
  • As the main objective of rice breeding programs, rice eating quality is one of critical factors directly determining the market price and the consumer preference. However, the genetic complexity of eating quality and the difficulty in accurate evaluation often constrain improvement of the eating quality in rice breeding programs. In addition, given that the rice eating quality of current cultivars has already reached some high-level, diversifying of genetic resources are demanded more than ever to improve the rice eating quality. In this study, we developed a recombinant inbred lines (RILs) population derive from Wandoaengmi6, a japonica-type Korean weedy rice with high eating quality and a high degree of glossiness of cooked rice. Year-to-year correlations between the traits in three years were shown normal distribution for major agronomic traits and physicochemical characteristics. After evaluating tested traits related to eating quality procedure, a total of ten lines were ultimately selected from the population. Increasement of the taste of cooked rice (TA) and the overall eating quality (OE) were confirmed in the selected lines, which are caused by alleles derived from Wandoaengmi6 without any linkage drag. These results indicate that the utility of wide genomic resources in Korean landrace could be of application in various rice breeding programs and countermeasure to contribute to properly response to climate change.

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Effects of Hysteroscopic Septotomy on Pregnancy in Patients with History of Infertility or Recurrent Spontaneous Abortion (불임 또는 습관성 유산 환자에서 중격자궁의 치료가 임신에 미치는 영향)

  • Koo, Hwa-Seon;Cha, Sun-Hwa;Yang, Kwang-Moon;Bae, Ju-Youn;Ahn, Hyun-Suk;Han, Ae-Ra;Park, Chan-Woo;Kang, Inn-Soo;Koong, Mi-Kyoung;Lee, Kyung-Sang
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.4
    • /
    • pp.361-368
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the influences of uterine septum and their elimination on the reproductive outcomes in women who have history of recurrent spontaneous abortion (RSA) and/or infertility. Methods: The medical records of reproductive outcomes in patients who have had history of RSA and infertility who were diagnosed with uterine septum only by hysterosalpingogram (HSG) between January 2008 and December 2009 were retrospectively analyzed. The subjects who have had severe male factor, tubal factors, other uterine factors, endocrine abnormalities, peritoneal factors, and abnormal karyotyping among both partners were excluded. In 27 patients, confirmation of diagnosis by laparoscopy and elimination of uterine septum by trans-vaginal hysteroscopy was done. Seventeen patients were strongly suspected to uterine septum on HSG but tried to get pregnancy without any other procedure for evaluation and management of uterine anomaly. Age matched 42 patients who have history of RSA and/or infertility and diagnosed to normal HSG finding at same period were randomly selected as control. The medical records of reproductive outcomes were analyzed and compared between groups. Results: The mean time of observation after diagnosis was 21.8 months (10 to 32). 55.6% (15/27) of patients in patients who received trans-vaginal hysteroscopic uterine septotomy were success to get pregnancies and was significantly higher than that of 17 patients who did not receive proper management (23.5%, 4/17, p<0.05). In control population, 40.5% (17/42) were success to pregnancies and the differences were not statistically significant compared to both two study groups. The live birth rate which was excluded pregnancy loss by abnormal fetal karyotyping and congenital anomaly were 75% (9/12) in treated septated uterus group and 84.6% (11/13) in control group each which have no statistically significant different. In patients with septated uterus who did not receive proper management showed lower delivery rate (50%, 2/4) than that of other groups but was not statistically significant. Conclusion: According to present data, women with a uterine septum have an increased chance of successful pregnancy with improved obstetric outcome after proper management of the uterine cavity. And these results were showed in patients with no regard to their reproductive history. But, in case of failed to receive proper management, uterine septum can affect not only pregnancy ongoing but successful pregnancy too.

NFC-based Smartwork Service Model Design (NFC 기반의 스마트워크 서비스 모델 설계)

  • Park, Arum;Kang, Min Su;Jun, Jungho;Lee, Kyoung Jun
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.157-175
    • /
    • 2013
  • Since Korean government announced 'Smartwork promotion strategy' in 2010, Korean firms and government organizations have started to adopt smartwork. However, the smartwork has been implemented only in a few of large enterprises and government organizations rather than SMEs (small and medium enterprises). In USA, both Yahoo! and Best Buy have stopped their flexible work because of its reported low productivity and job loafing problems. In addition, according to the literature on smartwork, we could draw obstacles of smartwork adoption and categorize them into the three types: institutional, organizational, and technological. The first category of smartwork adoption obstacles, institutional, include the difficulties of smartwork performance evaluation metrics, the lack of readiness of organizational processes, limitation of smartwork types and models, lack of employee participation in smartwork adoption procedure, high cost of building smartwork system, and insufficiency of government support. The second category, organizational, includes limitation of the organization hierarchy, wrong perception of employees and employers, a difficulty in close collaboration, low productivity with remote coworkers, insufficient understanding on remote working, and lack of training about smartwork. The third category, technological, obstacles include security concern of mobile work, lack of specialized solution, and lack of adoption and operation know-how. To overcome the current problems of smartwork in reality and the reported obstacles in literature, we suggest a novel smartwork service model based on NFC(Near Field Communication). This paper suggests NFC-based Smartwork Service Model composed of NFC-based Smartworker networking service and NFC-based Smartwork space management service. NFC-based smartworker networking service is comprised of NFC-based communication/SNS service and NFC-based recruiting/job seeking service. NFC-based communication/SNS Service Model supplements the key shortcomings that existing smartwork service model has. By connecting to existing legacy system of a company through NFC tags and systems, the low productivity and the difficulty of collaboration and attendance management can be overcome since managers can get work processing information, work time information and work space information of employees and employees can do real-time communication with coworkers and get location information of coworkers. Shortly, this service model has features such as affordable system cost, provision of location-based information, and possibility of knowledge accumulation. NFC-based recruiting/job-seeking service provides new value by linking NFC tag service and sharing economy sites. This service model has features such as easiness of service attachment and removal, efficient space-based work provision, easy search of location-based recruiting/job-seeking information, and system flexibility. This service model combines advantages of sharing economy sites with the advantages of NFC. By cooperation with sharing economy sites, the model can provide recruiters with human resource who finds not only long-term works but also short-term works. Additionally, SMEs (Small Medium-sized Enterprises) can easily find job seeker by attaching NFC tags to any spaces at which human resource with qualification may be located. In short, this service model helps efficient human resource distribution by providing location of job hunters and job applicants. NFC-based smartwork space management service can promote smartwork by linking NFC tags attached to the work space and existing smartwork system. This service has features such as low cost, provision of indoor and outdoor location information, and customized service. In particular, this model can help small company adopt smartwork system because it is light-weight system and cost-effective compared to existing smartwork system. This paper proposes the scenarios of the service models, the roles and incentives of the participants, and the comparative analysis. The superiority of NFC-based smartwork service model is shown by comparing and analyzing the new service models and the existing service models. The service model can expand scope of enterprises and organizations that adopt smartwork and expand the scope of employees that take advantages of smartwork.

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Legal Issues on the Collection and Utilization of Infectious Disease Data in the Infectious Disease Crisis (감염병 위기 상황에서 감염병 데이터의 수집 및 활용에 관한 법적 쟁점 -미국 감염병 데이터 수집 및 활용 절차를 참조 사례로 하여-)

  • Kim, Jae Sun
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.4
    • /
    • pp.29-74
    • /
    • 2022
  • As social disasters occur under the Disaster Management Act, which can damage the people's "life, body, and property" due to the rapid spread and spread of unexpected COVID-19 infectious diseases in 2020, information collected through inspection and reporting of infectious disease pathogens (Article 11), epidemiological investigation (Article 18), epidemiological investigation for vaccination (Article 29), artificial technology, and prevention policy Decision), (3) It was used as an important basis for decision-making in the context of an infectious disease crisis, such as promoting vaccination and understanding the current status of damage. In addition, medical policy decisions using infectious disease data contribute to quarantine policy decisions, information provision, drug development, and research technology development, and interest in the legal scope and limitations of using infectious disease data has increased worldwide. The use of infectious disease data can be classified for the purpose of spreading and blocking infectious diseases, prevention, management, and treatment of infectious diseases, and the use of information will be more widely made in the context of an infectious disease crisis. In particular, as the serious stage of the Disaster Management Act continues, the processing of personal identification information and sensitive information becomes an important issue. Information on "medical records, vaccination drugs, vaccination, underlying diseases, health rankings, long-term care recognition grades, pregnancy, etc." needs to be interpreted. In the case of "prevention, management, and treatment of infectious diseases", it is difficult to clearly define the concept of medical practicesThe types of actions are judged based on "legislative purposes, academic principles, expertise, and social norms," but the balance of legal interests should be based on the need for data use in quarantine policies and urgent judgment in public health crises. Specifically, the speed and degree of transmission of infectious diseases in a crisis, whether the purpose can be achieved without processing sensitive information, whether it unfairly violates the interests of third parties or information subjects, and the effectiveness of introducing quarantine policies through processing sensitive information can be used as major evaluation factors. On the other hand, the collection, provision, and use of infectious disease data for research purposes will be used through pseudonym processing under the Personal Information Protection Act, consent under the Bioethics Act and deliberation by the Institutional Bioethics Committee, and data provision deliberation committee. Therefore, the use of research purposes is recognized as long as procedural validity is secured as it is reviewed by the pseudonym processing and data review committee, the consent of the information subject, and the institutional bioethics review committee. However, the burden on research managers should be reduced by clarifying the pseudonymization or anonymization procedures, the introduction or consent procedures of the comprehensive consent system and the opt-out system should be clearly prepared, and the procedure for re-identifying or securing security that may arise from technological development should be clearly defined.