• Title/Summary/Keyword: evaluation procedure

Search Result 2,461, Processing Time 0.034 seconds

Clinical evaluation of $Br{\aa}nemark$ Ti-Unite implant and ITI SLA implant in the post maxillary area with sinus elevation technique. (상악동 거상술을 이용하여 구치부에 식립된 $Br{\aa}nemark$ Ti-Unite와 ITI SLA 임플란트의 임상적 평가)

  • Hong, Seong-Bae;Chai, Gyung-Joon;Jung, UI-Won;Kim, Chang-Sung;Chim, Joon-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.813-822
    • /
    • 2005
  • The predictable outcome of implant placement in the atrophic maxilla with sinus floor elevation procedure(osteotome sinus floor elevation technique and window opening technique) is well documented. Aim of this study was to evaluate the efficacy of $Br{\aa}nemark$ Ti-Unite implant system and ITI SLA implant system placed in the atrophic posterior maxilla with sinus floor elevation procedure. Eighty patients received placement of $Br{\aa}nemark$ Ti-Unite implants(195 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(153 osteotome sinus floor elevation technique and 42 window opening procedure). Fifty patients received placement of ITI SLA implants(83 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(77 osteotome sinus floor elevation technique and 6 window opening procedure). Chart review were taken from each patient. The total failed implants were seven and the total implant survival rate was 96.4% in $Br{\aa}nemark$ Ti-Unite system. The total failed implants were one and the total implant survival rate was 98.8% in ITI SLA system. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in $Br{\aa}nemark$ Ti-Unite system. The implant survival rate with osteotome technique was 98.7% and 100% with window opening. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in ITI SLA system. The results of this evaluation show that the placement of $Br{\aa}nemark$ Ti-Unite system as well as ITI SLA system is a reasonable treatment option for patients with the atrophic posterior maxillary area.

Establishment and Validation of Gold Amalgamation Method for the Quantitation of Thimerosal in Biological Products (생물학적제제의 치메로살 함량 정량을 위한 가열기화 아말감 흡광도법의 확립 및 검증)

  • Kim, Byung-Chul;Kim, Do-Keun;Hong, Sung-Hwa;Kim, Yeon-Hee;Lim, Jong-Mi;Won, Yun-Jung;Kim, Seok-Hwan;Hong, Ji-Young;Yun, Young-Min;Kim, Jae-Ok
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.284-288
    • /
    • 2011
  • The test method for biologics of lot release system is based on 'Test procedure and specification for biological products,' generally, thimerosal content is measured by chemical analysis using O.D. In this study, the comparative analysis was carried out using the gold amalgamation method for thimerosal content was compared to the existing methods, which are described above. The gold amalgamation method, which uses atomic absorption spectrophotometry, was meets all the method validation acceptance criteria. It is considered to be proper as the assay and identification test for thimerosal. In this study, the comparative analysis was performed three times. As a result, gold amalgamation method is more convenient and easy to perform as this assay doesn't have pre-treatment procedure. Also this assay showed good precision and reproducibility compared to the conventional method. Therefore, it is appropriate to alternate the assay method of thimerosal from the conventional chemical analysis to gold amalgamation method to improve the credibility of lot release system and the quality control of biologics, by standardizing test method.

A Study on the Evaluation Method about Marketability of Product Design (제품디자인의 시장성 평가방법 연구)

  • 이문기
    • Archives of design research
    • /
    • v.14 no.1
    • /
    • pp.93-101
    • /
    • 2001
  • This study suggested how to apply it decision-making of product development rapidly by design evaluation process to objectify and the result to quantify with viewpoint of design evaluation sets to marketability. Coverage of this method limited to the evaluation stage of design concept. The procedure of study, first of all, referred to some type of design evaluation method and their feature. And next, referred to some kinds of demand forecasting for marketing. Above an, this study focused on the method of demand forecasting by buying intentions surveys proper to the marketability evaluation of new product design. On a case study, I had investigated preference survey and buying intentions surveys about the design proposal of "language master audio". I selected the best design proposal through the conjoint analysis and also investigated demand forecasting. First, on the basis of buying intentions surveys, choose population and had produced buying demand, awareness demand, potential demand. I could estimate some profit to take out expense and cost from the buying demand. This estimated profit is marketability judgement data of product design at the design concept stage and can be utilized to measurable data for decision-making of product development. Through the case study, this method could forecast a target demand, and even if it is some difference between real sales volume, but the case study could verified that this method is effective to the evaluation of marketability in case of completely new product got on the typical category and the product category could be set up the population clearly.

  • PDF

Resources Evaluation System for Rural Planning Purposes(III) - Rating Tabulation for Rural Resources Evaluation Items- (농촌계획지원용 지역자원펑가시스템 구축(III) - 농촌자원평가를 위한 평가등급기준 설정 -)

  • Choe, Su-Myeong;Han, Gyeong-Su;Hwang, Han-Cheol
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.1
    • /
    • pp.75-85
    • /
    • 1998
  • This study, a sub-one of comprehensive research works titled under "Rural Resources Evaluation System", tried to propose a rational methodology for development of rating tabulation on evaluation items. Firstly, the database system for handling of original/processed data of each evaluation items was constructed, being mainly focussed on the possibilities of data acquisition and statistical treatment. The rating tabulation system developed in the study has the formalized evaluation classes as 2 or 5 for convenience/simplification of analysis works. For each evaluation item in lower step of the goal system, 5 types of rating technique were arranged, which were based on statistical analysis using mean and standard deviation values(Type I), its existence or not(Type II), relative significance of its holding volume(Type III), synthesized weighting scale of its quality and quantity(Type IV), and the others(Type V). And, standardized 4-steps procedure for rating tabulation was proposed. Finally, the rating tabulation system developed in the study was applied to each evaluation item of goal system, from which the numerically-valued ranking criteria was obtained.

  • PDF

Strength Demand Calculation for Retrofitting Unreinforced Masonry Buildings Based on the Displacement Coefficient Method and the Preliminary Seismic Evaluation Procedure (변위계수법 및 약산식 내진성능평가에 기초한 비보강 조적조 건물의 내진보강 요구강도 산정)

  • Seol, Yun Jeong;Park, Ji-Hun;Kwak, Byeong Hun;Kim, Dae Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2022
  • Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in "Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed." The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.

Development of Evaluation System for Visibility of Variable Message Sign (VMS의 시인성 향상을 위한 시인성 성능평가 항목 및 평가기준 설정과 물리적 평가시스템 구축)

  • Lee, Sang Hyup;Baik, Nam Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.219-223
    • /
    • 2006
  • Variable Message Sign(VMS) is one of the most popular travel information system. In this study, the evaluation categories, each category's datum value and evaluation procedure for enhancing the visibility of VMS are studied and the physical evaluation system is developed. The evaluation categories have been developed based on the analysis of previous guidelines used in Korea, Europe and the United States. The evaluation categories include luminance, luminance ratio, beam width, color, and uniformity. The physical evaluation system consists of goniometer, solar simulator, luminance meter, sensor and rack system. As a result of this study, the quantitative and effective evaluation of VMS visibility would become possible.

The Results of Modified $Brostr{\ddot{o}}m$ Procedure for the Treatment of Chronic Lateral Ankle Instability (만성 족근 관절 외측 불안정성 환자에서 $Brostr{\ddot{o}}m$ 변형 술식의 치료 결과)

  • Jeon, Ho-Seung;Jeon, Seung-Ju;Kim, Jong-Min;Park, Byeong-Mun;Chang, Byung-Keun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.60-65
    • /
    • 2006
  • Purpose: This study was performed to evaluate clinical and radiographical results of treatment of chronic lateral ankle instability with modified Brostrom procedure. Materials and Methods: This is a retrospective study of 22 cases in 22 patients treated with modified $Brostr{\ddot{o}}m$ procedure under the diagnosis of chronic lateral ankle instability from May 2000 to August 2004. Average age was 32.3 years. Average follow-up period was 23 months. Preoperative and postoperative radiographs of ankle anteroposterior view, lateral view and varus stress view were analyzed. The clinical evaluation was performed according to the Americal Orthopaedic Foot and Ankle Society scales. Results: After the modified $Brostr{\ddot{o}}m$ procedure, Americal Orthopaedic Foot and Ankle Society scales score was improved by average 28 points. Among the 22 cases, 13 cases were excellent, 3 cases good, 4 cases fair, and 2 cases poor with satisfaction of 73%. Five cases had intermittent ankle pain of whom 3 cases had difficulty during competitive sports activity. Lateral tilting of talus improved by average 5.4 degrees on varus stress view. Conclusions: The modified $Brostr{\ddot{o}}m$ procedure is one of the most effective methods for treating of chronic lateral ankle instability.

  • PDF

Bone-added osteotome sinus floor elevation with simultaneous placement of non-submerged sand blasted with large grit and acid etched implants: a 5-year radiographic evaluation

  • Jung, Jee-Hee;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.69-75
    • /
    • 2010
  • Purpose: Implant survival rates using a bone-added osteotome sinus floor elevation (BAOSFE) procedure with simultaneous placement of a non-submerged sand blasted with large grit and acid etched (SLA) implant are well documented at sites where native bone height is less than 5 mm. This study evaluated the clinical results of non-submerged SLA Straumann implants placed at the time of the BAOSFE procedure at sites where native bone height was less than 4 mm. Changes in graft height after the BAOSFE procedure were also assessed using radiographs for 5 years after the implant procedure. Methods: The BAOSFE procedure was performed on 4 patients with atrophic posterior maxillas with simultaneous placement of 7 non-submerged SLA implants. At least 7 standardized radiographs were obtained from each patient as follows: before surgery, immediately after implant placement, 6 months after surgery, every year for the next 3 years, and after more than 5 years had passed. Clinical and radiographic examinations were performed at every visit. Radiographic changes in graft height were calculated with respect to the implant's known length and the original sinus height. Results : All implants were stable functionally, as well as clinically and radiographically, during the follow-up. Most of the radiographic reduction in the grafted bone height occurred in the first 2 years; reduction after 2 years was slight. Conclusions: The simultaneous placement of non-submerged SLA implants using the BAOSFE procedure is a feasible treatment option for patients with severe atrophic posterior maxillas. However, the grafted bone height is reduced during the healing period, and patients must be selected with care.

A Compaction Control Procedure of Railway Trackbed Fills Using Elastic Waves (탄성파를 이용한 철도노반의 다짐관리 방안)

  • Park, Chul-Soo;Park, In-Beom;Oh, Sang-Hoon;Kim, Hak-Sung;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1427-1439
    • /
    • 2008
  • The quality of track-bed fills of railways has been controlled by field measurements of density (${\gamma}_d$) and the results of plate-load tests. The control measures are compatible with the design procedures whose design parameter is $k_{30}$ for both ordinary-speed railways and high-speed railways. However, one of fatal flaws of the design procedures is that there are no simple laboratory measurement procedures for the design parameters ($k_{30}$ or, $E_{v2}$ and $E_{v2}/E_{v1}$) in design stage. A new quality control procedure, in parallel with the advent of the new design procedure, is being proposed. This procedure is based upon P-wave velocity involving consistently the evaluation of design parameters in design stage and the field measurements during construction. The key concept of the procedure is that the target value for field compaction control is the P-wave velocity determined at OMC using modified compaction test, and direct-arrival method is used for the field measurements during construction. The procedure was verified at a test site and the p-wave velocity turned out to be an excellent control measure. The specifications for the control also include field compaction water content of $OMC{\pm}2%$ as well as the p-wave velocity.

  • PDF

Evaluation of Zone 2 Thoracic Endovascular Aortic Repair Performed with and without Prophylactic Embolization of the Left Subclavian Artery in Patients with Traumatic Aortic Injury

  • Miju Bae;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Seon Uoo Choi;Seunghwan Song
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.577-583
    • /
    • 2021
  • Objective: To report the authors' experience in performing thoracic endovascular aortic repair (TEVAR) for zone 2 lesions after traumatic aortic injury (TAI). Materials and Methods: This retrospective review included 10 patients who underwent zone 2 TEVAR after identification of aortic isthmus injury by CT angiography (CTA) upon arrival at the emergency room of a regional trauma center from 2016 to 2019. Patients were classified into two groups: those who underwent left subclavian artery (LSA) embolization concurrently with the main TEVAR procedure, and those in whom LSA embolization was not performed during the main procedure, but was planned as a bailout treatment if type II endoleak was noted on follow-up CTA images. Pre-procedural and procedure-related factors and post-procedure prognosis were compared between the groups. Results: There were no differences in pre-procedural factors, occurrence of endoleaks, and post-procedure prognosis (including mortality) between patients in the two groups. The duration of the procedure was shorter in the non-LSA embolization group (61 minutes vs. 27 minutes, p = 0.012). During follow-up, type II endoleak did not occur in either group. Conclusion: Delaying preventative LSA embolization until stabilization of the patient would be desirable when performing zone 2 TEVAR for TAI, in the absence of endoleak on the completion aortography image taken after complete deployment of the stent graft.