• Title/Summary/Keyword: evaluation procedure

Search Result 2,446, Processing Time 0.033 seconds

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

Shear stress indicator to predict seismic performance of residential RC buildings

  • Tekeli, Hamide;Dilmac, Hakan;Demir, Fuat;Gencoglu, Mustafa;Guler, Kadir
    • Computers and Concrete
    • /
    • v.19 no.3
    • /
    • pp.283-291
    • /
    • 2017
  • A large number of residential buildings in regions subjected to severe earthquakes do not have enough load carrying capacity. The most of them have been constructed without receiving any structural engineering attention. It is practically almost impossible to perform detailed experimental evaluation and analytical analysis for each building to determine their seismic vulnerability, because of time and cost constraints. This fact points to a need for a simple evaluation method that focuses on selection of buildings which do not have the life safety performance level by adopting the main requirements given in the seismic codes. This paper deals with seismic assessment of existing reinforced concrete residential buildings and contains an alternative simplified procedure for seismic evaluation of buildings. Accuracy of the proposed procedure is examined by taking into account existing 250 buildings. When the results of the proposed procedure are compared with those of the detailed analyses, it can be seen that the results are quite compatible. It is seen that the accuracy of the proposed procedure is about 80% according to the detailed analysis results of existing buildings. This accuracy percentage indicates that the proposed procedure in this paper can be easily applied to existing buildings to predict their seismic performance level as a first approach before implementing the detailed and complex analyses.

Seismic performance evaluation of a RC special moment frame

  • Kim, Taewan;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • v.27 no.6
    • /
    • pp.671-682
    • /
    • 2007
  • The probability and the reliability-based seismic performance evaluation procedure proposed in the FEMA-355F was applied to a reinforced concrete moment frame building in this study. For the FEMA procedure, which was originally developed for steel moment frame structures, to be applied to other structural systems, the capacity should be re-defined and the factors reflecting the uncertainties related to capacity and demand need to be determined. To perform the evaluation procedure a prototype building was designed per IBC 2003, and inelastic dynamic analyses were conducted applying site-specific ground motions to determine the parameters for performance evaluation. According to the analysis results, distribution of the determined capacities turned out to be relatively smaller than that of the demands, which showed that the defined capacity was reasonable. It was also shown that the prototype building satisfied the target performance since the determined confidence levels exceeded the objectives for both local and global collapses.

An Analysis of Teachers' Self-evaluation on Health Teaching Behaviors in Elementary School (초등 학교 교사의 보건수업 행동 평가 분석)

  • 오문식;박영수
    • Korean Journal of Health Education and Promotion
    • /
    • v.15 no.2
    • /
    • pp.81-93
    • /
    • 1998
  • The purpose of this study was to analyze the results of teachers' self-evaluation on their health teaching behaviors, then to furnish the basic data to be able to improve teachers' health teaching activities and the educational issues on the education of teachers. To put above aims into practice, these were required: 1. Are there any differences in the results of self-evaluation on health teaching behaviors factors by teachers? 2. Are there any differences in the results of health teaching self-evaluation whether he/she take P.E as major of study in-serviece training period? 3. Does it have any influence on the results of health teaching self-evaluation whether he or she completed on the job training for the school health? 4. Are there any differences in the results of health teaching self-evaluation by sex and career? To carry out a research for this purpose, the factors of health teaching self-evaluation were divided into the clearness of the procedure, the active interaction, the variety of the ways showing the contents, and the individualization of the procedure. Then a questionnaire form, consisting of 28 specific inquires to evaluate health teaching behaviors, was delivered and conducted by 450 teacher of the elementary school in Kyungki-do. The analysis of data was done by SPSS; producing mean and standard deviation and they were inspected statistically to compare the evaluation levels and find out the differences by teachers' personal variables. The conclusion were as follows: 1. In the self-evaluation level of teachers' health teaching behaviors, teachers showed 68.23 point as are percentile distribution. And it was in order of a school-nurse(71.68), an athletic teacher(67.29), and a class-room teacher (65.66). Score obtained by teacher was statistically significant difference (p〈.001) 2. In the factors affecting to teachers' health instruction, “active interaction” showed the highest score(18.55), “variety of ways showing the contents”(17.38), “clearness of the procedure” (16.70), and “individualization of the procedure” (15.59). In the analysis of the differences by teachers, according to factors, there were significant differences in “active interaction”, “variety of the ways showing contents”, “clearness of the procedure”(p〈.001). 3. Self-evaluation score for graduates from Dept. of P. E in Teachers' collage was not significant difference compared with other majors(p〉.05). 4. Teachers receiving health education was significantly higher self-evaluation score than that of teachers not-receiving health education (P〈.01). 5. Self-evaluation score of female teacher was significant difference compared with that of male teacher (p〈.001). 6. Career (working duration) did not influenced to self-evaluation score on health teaching behaviors (P〉 .05). On the basis of the conclusion of this study, the next are suggested: First, the further studies to make use of the results of health teaching behaviors and to examine the effect are needed. Second, the further studies to examine the relations between academic achievement and teachers' major(a school-nurse, an athletic teacher, and a class-room teacher) are needed. Third, the following studies to improve health teaching by both teachers' self-evaluation on health teaching behaviors and students' evaluation of teachers, and to find out more effective health teaching, are needed. Fourth, Health education for pre-service training course and On-the-Job training program are need the effective factors on the teachers' Health teaching obtained from this study.

  • PDF

EVALUATION OF VEHICLE DYNAMIC CONTROL FOR ROLOVER PREVENTION

  • Ungoren, A.Y.;Peng, H.
    • International Journal of Automotive Technology
    • /
    • v.5 no.2
    • /
    • pp.115-122
    • /
    • 2004
  • Evaluation of active safety control systems usually relies heavily on field testing and is time-consuming and costly. Advances in computer simulations make it possible to perform exhaustive design trials and evaluations before field testing, and promise to dramatically reduce development cost and cycle time. In this paper, a comprehensive simulation-based evaluation procedure is proposed, which combines standard evaluation maneuvers, worst-case techniques, and a driver model for closed-loop path following evaluations. A vehicle dynamic controller (VDC) for a popular Sport Utility Vehicle is evaluated using the proposed procedure. Simulation results show that the proposed procedure can be used to assess the performance of the VDC under various conditions and provides valuable information for the re-design of the VDC.

On the Evaluation of Speech Recognition Systems (음성 인식 기술 평가 동향)

  • Yu, Ha-Jin;Kim, Dong-hyun;Yook, Dong-suk
    • Proceedings of the KSPS conference
    • /
    • 2005.11a
    • /
    • pp.201-206
    • /
    • 2005
  • We present a survey on the evaluation methods of speech recognition technology and propose a procedure for evaluating Korean speech recognition systems. Currently there are various kinds of evaluation events conducted by NIST and ELDA every year. In this paper, we introduce these activities, and propose an evaluation procedure for Korean speech recognition systems. In designing the procedure, we consider the characteristics of Korean language, as well as the trends of Korean speech technology industry.

  • PDF

A Survey on the Workload Evaluation Methods and Their Applications to WMSD Work in Industries (작업평가방법론 및 현장 적용 고찰)

  • Park, Jae-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.435-444
    • /
    • 2010
  • To identify and evaluate the risk factors in WMSD work, a number of ergonomic workload evaluation methods have been developed. In the legal examination of WMSD risk factors, simple observational workload evaluation methods are widely used instead of using costly measurement equipments such as EMG and motion analyzer. The simple workload evaluation methods can be categorized into three groups; risk factor checklist methods, posture observation methods, and manual material handling task evaluation methods. In terms of the categories, this survey summarized several representative workload evaluation methods and compared them each other. Then some industrial application cases referring each the workload evaluation methods were surveyed. Due to the characteristics of each method, the selection and application procedure of workload evaluation method should be appropriate for the corresponding work. Therefore, some guidelines for the selection and application procedure of workload evaluation method were suggested.

Prioritisation of Medical Procedure for Health Technology Assessment (전문의 대상 설문조사를 이용한 보건의료 기술평가 대상 시술의 우선 순위 선정 - 이비인후과와 흉부외과를 중심으로 -)

  • 안형식;김선민;신영수;김차엽;김선미;이순형
    • Health Policy and Management
    • /
    • v.7 no.2
    • /
    • pp.46-64
    • /
    • 1997
  • Background & Objectives : Korea is face with the social need for health care technology assessment so that it is urgently needed to found principles and methodology in technology assessment in health care. As a groundwork for health care technology assessment, we tried to prioritize medical technology for assessment. Among medical technologies, procedure is somewhat difficult to assess, compared to drug or equipment. In this study, we aimed at the prioritisation of medical procedure to be assessed, in terms of efficay, safety, and adequacy. Method : For the standardized classification of medical procedure, ICD-9-CM(International Classification of Diseases 9th edition - Clinical Modification) was used. Among the list the procedures coming under otorhinolaringjology and thoracic surgery were selected by three family physicians. The list of procedure was mailed to the board certified surgeons of both disciplines, with the question asking about the necessity for assessment in terms of efficay, safety, and adequacy. Replied questionnaires were analyzed in each procedure. Results : Of 560 otorhinolaryngologist and 480 thoracic surgeon, 114 surgeons replied. Of otorhinolaryngological procedure, incision, excision, and destruction of inner ear : fenestration of inner ear : stapedectomy and its revision were the most urgent technology to assess in the aspect of safety. For adequacy, operations on Eustachian tube: fenestration of inner ear: incision, excision, and destruction of inner ear were highly ranked in necessity, and for efficary, operations on Eustachian tube; external maxillary antrotomy; fenestration of inner ear. Thoracic surgeons replied thoracic procedures, lung transplantation; heart transplantation; implantation of heart assist system [pump] are most important for evaluation in terms of safety; and heart transplantation; Lung transplantation; Implantation of heart assist system [pump] in terms of adequacy, and surgical collapse of lung [Artificia니 pnemothorax or pnuexoperitoeum]; lung transplantation; periarterial sympathectomy in terms of efficacy. As a whole, surgeons regard safety evaluation is more urgent than adequacy or efficary. In addition, otorhinolaryngological surgeons regard evaluation of their procedures more urgent than thoracic surgeons regard theirs. Conclusion : By the questionnaire to board certified physicians, we get some preliminary data for prioritisation of technologies to assess. Through the questionnaire like this, much information would be gathered for technology assessment, especially for medical procedure, if not enough. In the near future, well structured expert opinion gathering research, such as modified Delphi or nominal group technique, should be done succeedingly.

  • PDF

Procedure of Seismic Performance Evaluation of LNG Receiving Terminal Facilities (천연가스 생산기지 시설물의 내진성능평가 절차)

  • Lee, Tae-Hyung;Lee, Eunsuk;Park, Taekyu;Hong, Seong Kyeong;Kim, Joonho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.110-115
    • /
    • 2014
  • It is crucial for important facilities to withstand strong earthquakes because their damage may cause undesirable socio-economic effect. A liquefied natural gas (LNG) receiving terminal is one of the lifeline facilities whose seismic safety needs to be guaranteed. Even though all operating LNG receiving terminals in Korea were seismically designed, old design codes do not guarantee to comply with the current seismic design codes. In addition, if the constructional materials have been deteriorated, the seismic capacity of facilities may be also deteriorated. Therefore, it is necessary that the seismic performance of LNG receiving terminals is evaluated and the facilities that lack of seismic capacity have to be rehabilitated. In this paper, a procedure of seismic performance evaluation of such facilities is developed such that the procedure consists of three phases, namely pre-analysis, analysis, and evaluation phases. In the pre-analysis phase, design documents are reviewed and walk-on inspection is performed to determine the current state of the material properties. In the analysis phase, a structural analysis under a given earthquake or a seismic effect is performed to determine the seismic response of the structure. In the evaluation phase, seismic performance of the structure is evaluated based on limit states. Two of the important facilities, i.e. the submerged combustion vaporizer (SMV) and pipe racks of one of the Korean LNG receiving terminals are selected and evaluated according to the developed procedure. Both of the facilities are safe under the design level earthquake.

Seismic Performance Evaluation of Unreinforced Masonry Buildings Retrofitted by Strengthening External Walls (외부벽체 강도증진형 보강이 적용된 비보강 조적조 건물의 내진성능평가)

  • Seol, Yun Jeong;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.77-86
    • /
    • 2020
  • Nonlinear static analysis and preliminary evaluation were performed in this study to evaluate the seismic performance of unreinforced masonry buildings subjected to various soil conditions based on the revised Korean Building Code. Preliminary evaluation scores and nonlinear static analyses indicated that all buildings were susceptible to collapse and did not reach their target performance. Therefore, retrofit of those building models was carried out through a systematic procedure to determine areas to be strengthened. It was possible to make most building models satisfy performance objectives through the reinforcement alone of damaged external shear walls. However, the application of a preliminary evaluation procedure to retrofit design was found to be too conservative because all the retrofitted building models verified with nonlinear static analysis failed to satisfy performance objectives. Therefore, it is possible to economically retrofit unreinforced masonry buildings through the fortification of external walls if a simple evaluation procedure that can efficiently specify vulnerable parts is developed.