• Title/Summary/Keyword: evaluation limitation

Search Result 750, Processing Time 0.028 seconds

A Study on Comparative Analysis of Mammography and Tc-99m MIBI Scintimammography for Dense Breast (치밀형 유방에서 유방특이감마영상검사의 유용성 평가)

  • Jeong, Eun-Mi;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.76-79
    • /
    • 2012
  • Purpose: This study was to evaluate usefulness of $^{99m}Tc$-MIBI scintimammography for dense breast by comparing concordance in test results between Tc-99m MIBI scintimammography and mammography whose effect was proved the most as an imaging tool depending on breast density and at the same time by examining limitation on evaluation depending on density of breast tissue. [Materials and Methods] In the period from December 2010 to July 2011, this study targeted 150 patients who took both of $^{99m}Tc$-MIBI scintimammography and mammography conducted by using breast gamma camera in this hospital. Breast density was classified to the four levels of pattern 1~4 based on the results of mammography. $^{99m}Tc$-MIBI scintimammography was conducted with the LCC, the RCC, the LMLO, and the RML one minute after intravenous injection of 99mTc-MIBI 7400 MBq (20 mCi) while analysis was made for concordance in test results of $^{99m}Tc$-MIBI scintimammography and mammography. [Results] Among the 150 patients, pattern 1 was found in 3 patients, pattern 2 in 44 patients, pattern 3 in 61 patients, and pattern 4 in 37 patients. There were 5 patients who showed the case where it was impossible to determine density of breast tissue due to foreign body inserted to breast. The concordance ratio of the results between $^{99m}Tc$-MIBI scintimammography and mammography was 95.5% for pattern 2, 95.1% for pattern 3 and 94.6% for pattern 4. This demonstrated that the concordance rate decreased according to the increase in breast density. [Conclusion] When there was limitation on evaluation of breast specific gamma imaging test results due to increased intake in breast tissue or surgical site, the concordance rate was 6.8% for pattern 2, 16.3% for pattern 3 and 18.9% for pattern 4. This demonstrated that the degree of limitation on evaluation of breast specific gamma imaging test results increased according to the increase in breast density.

  • PDF

A migration based reconstruction algorithm for the imaging of defects in a plate using a compact array

  • Muralidharan, Ajith;Balasubramaniam, Krishnan;Krishnamurthy, C.V.
    • Smart Structures and Systems
    • /
    • v.4 no.4
    • /
    • pp.449-464
    • /
    • 2008
  • An array based, outward monitoring, ultrasonic guided wave based SHM technique using a single transmitter and multiple receivers (STMR), with a small footprint is discussed here. The previous implementation of such SHM arrays used a phase-reconstruction algorithm (that is similar to the beam-steering algorithm) for the imaging of reflectors. These algorithms were found to have a limitation during the imaging of defects/reflectors that are present in the "near-field" of the array. Here, the "near-field" is defined to be approximately 3-4 times the diameter of the compact array. This limitation is caused by approximations in the beam-steering reconstruction algorithm. In this paper, a migration-based reconstruction algorithm, with dispersion correction in the frequency domain, is discussed. Simulation and experimental studies are used to demonstrate that this algorithm improves the reconstruction in the "near-field" without decreasing the ability to reconstruct defects in the "far-field" in both isotropic and anisotropic plates.

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope (외피 열성능에 따른 건물에너지효율등급 분석 연구)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.59-64
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Window and Wall in Apartment Houses (창호 및 벽체의 단열성능에 따른 건물에너지효율등급 평가 연구 -공동주택을 중심으로-)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Kim, Ji-Yeun;Jang, Cheol-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.608-613
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

  • PDF

Evaluation on Maximum Irrigation Amounts of Groundwater Keeping up with a Demand During Short-term Drought (가뭄 수요대응 단기간 허용 가능한 최대 취수량 평가)

  • Lee, Byung Sun;Myoung, Wooho;Lee, Gyusang;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.76-87
    • /
    • 2021
  • Groundwater is considered to be the best water resource to solve water shortage problems during drought periods. Even though excessive pumping (overdraft) during short-period may give an unprofitable effect on groundwater hydrology, it has a primary role to solve a lack of water resources and to maintain incomes of farmers. This study evaluated maximum irrigation amounts of groundwater to each local-government and province during drought periods. Maximum irrigation amounts of groundwater were evaluated using cumulative groundwater usage data of each local-government during normal and drought years. Maximum irrigation amounts of groundwater during drought periods would be roughly identified as approximately 1.3 times more than the exploitable amounts of groundwater resources for each local-government. Drawdown-limitation depth on groundwater levels at each monitoring well was determined by transforming the maximum irrigating amounts into degree of change on levels. Universal limitation depth of drawdown on groundwater levels was evaluated to be approximately three times of annual fluctuating range on groundwater levels for each monitoring well. Systematic response on groundwater demands with abiding by drawdown-limitation depth can attain an optimal irrigation of groundwater resources during short-term drought.

On the Fuzzy Approach to Integrated Evaluation of Complex Systems (퍼지 평가의 통합특성에 관하여)

  • 이철영;임봉택
    • Journal of Korean Port Research
    • /
    • v.13 no.1
    • /
    • pp.79-86
    • /
    • 1999
  • This paper deals with the evaluation problem of complex systems by introducing a fuzzy approach. The authors are functionally supposing a hierarchical structure model of a complex system and give light on the following problems. First for the purpose of clarifying the characteristics of measures the property and differences between two method such as linear and fuzzy viewpoint are discussed through two level-down evaluation process. Second the integrated evaluation process which keeps reversibility between hierarchical levels is discussed and obtained some necessary conditions for reversibility of fuzzy evaluation. From these results it is expected that the fuzzy approach overcomes partly the limitation of reductionism at the hierarchical evaluation of complex systems.

  • PDF

Long-term Evaluation of Occlusal Adjustment in Patients with Temporomandibular Disorders (측두하악장애환자의 교합교정에 관한 장기평가)

  • Myung Yun Ko;Ki Hong Kwon;Jeom Il Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 1986
  • 18 TMD patients who received occlusal adjustment in PNUH though Jan.1984 to 1985 were followed up for short-term(2-6yrs.) and long-term(1-2yrs.) evaluation. The obtained results were as follows : 1. Pain index showed gradual decrease after occlusal adjustment and significant change on long-term evaluation. 2. Noise index had no significant change throughout the all follow-up evaluation. 3. Opening limitation index showed gradual decrease after occlusal adjustment and significant change on both long-term and short-term evaluation. 4. Maximum comfortable opening exhibited more and more increase and significant change on long-term evaluation.

  • PDF

A Development of Evaluation Indicators for Information Security by Means of the Coincidence Analyses (부합성 분석을 통한 정보보안 평가지표 개발)

  • Lee, Yeong-Kyu;Kim, Sang-Hoon
    • Journal of Information Technology Services
    • /
    • v.7 no.3
    • /
    • pp.175-198
    • /
    • 2008
  • The wide spread of the Internet has become a momentum to promote informatization, and thus individuals, organizations, and government bodies are competitively participating in this kind of new wave. Informatization enables us not only to circulate and utilize information without any limitation but also to maximize users' benefits and convenience. On the other hand, it brings about negative effects-security incidents such as cyber terror, Internet fraud and technology leakage, etc. Evaluation on security level should precede over all the others in order to minimize damage by security incidents since it diagnoses current status on security as it is and can be used as a guideline for appropriate security management. In this study, evaluation domains, items and indicators of information security to evaluate information security are theoretically developed on the basis of critically reviewing the major existing research. And then the coincidence level(content validity, ease and reliability of evaluation) of each evaluation indicators are empirically analyzed through performing the field study of 83 information security experts.

Improvement of Field Assessment List for Slope-stability Estimation (국내외 급경사지 평가표 분석을 통한 개선방안 연구)

  • Son, Young-Jin;Park, Dug-Keun;Oh, Jeong-Rim;Song, Young-Karb
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.509-522
    • /
    • 2010
  • There is a increasing trend in disaster occurrence due to steep-slope failures in urban area during typhoon and torrential rain season in Korea. The underlying hazards that cause slope failure are mainly linked with urbanization and industrialization. To minimize the disaster damages by slope failure, objective and unified evaluation approached are desired. Since currently available evaluation checklists are developed for specific purposed, there is a limitation to adapt those checklists for stability evaluation in natural terrain. This study proposes an improved evaluation checklist based on the comparison of previous checklists and applicability and feasibility are analyzed implementing field application.

  • PDF

An Efficiency Evaluation among Manufacturing Processes using Hybrid DEA/AHP Model (DEA와 AHP 모형을 이용한 제조공정들 간 효율성 평가)

  • Kim, Jun-Beom;Kim, Woo-Je;Cho, Nam-Wook
    • IE interfaces
    • /
    • v.21 no.3
    • /
    • pp.302-311
    • /
    • 2008
  • Efficiency evaluation methods of manufacturing processes have relied on absolute measures such as defective rate and throughput per person, ignoring various process characteristics. To overcome the limitation, we propose an evaluation model which reflects characteristics of each process. It is composed of three measures : utilization, performance, and improvement. The suggested model utilizes a combination of DEA and AHP methods. The proposed method has been applied to efficiency evaluation of cellular phone case manufacturing processes.