• 제목/요약/키워드: evaluation and retrofit

검색결과 148건 처리시간 0.023초

탄소섬유로 휨보강된 RC 부재의 손상정도에 따른 보유내력평가 (Flexural Capacity Evaluation of RC Member Retrofitted by CFS and with Various Damage Level)

  • 서수연;김경태;윤승조;윤현도;최창식;최기봉
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.326-329
    • /
    • 2006
  • Strengthening method using CFS have been developed for the rehabilitation of structures. However, it is very difficult to estimate their resistance capacity after retrofit. Therefore, damage information for strengthened structure with CFS investigated and the estimation method structural capacity by using the damage information is developed. The final objective of this research work is to propose the guideline and method for resistance capacity estimate of structure. In this paper, experimental study result with test parameters of number of carbon fiber sheets and bonding ratio is introduced.

  • PDF

경유차 적용 디젤산화촉매장치의 성능 변화 분석 (An Investigation of Performance Change of Diesel Oxidation Catalyst for Diesel Vehicle)

  • 황진우;이창식
    • 한국분무공학회지
    • /
    • 제14권1호
    • /
    • pp.15-19
    • /
    • 2009
  • This paper is to investigated the analysis of performance characteristics of diesel oxidation catalyst (DOC) for diesel vehicle with 2.5L piston displacement. The performance evaluation test of DOC applied to test diesel vehicle was carried out for four kinds of DOCs manufactured from different company. The testing DOCs were randomly selected from the retrofit vehicle and then standard test vehicle that was representative for the application group was equipped with DOC for the test. In this verification test, the reduction rate of particulate matter (P.M.) and the deviation of the performance of the DOC were examined through CVS-75 mode of the standard vehicle and SOF reduction rate of specific DOC was investigated. It was found that some DOCs failed to pass the criteria of the P.M. reduction rate because of the reason seen catalyst aging even if they were same devices. In the result of SOF analysis, the specific DOC showed more PM reduction than SOF of PM. reduction exceptionally.

  • PDF

Seismic evaluation of existing RC frames with wide beams using an energy-based approach

  • Benavent-Climent, A.;Zahran, R.
    • Earthquakes and Structures
    • /
    • 제1권1호
    • /
    • pp.93-108
    • /
    • 2010
  • This paper investigates the seismic performance of existing reinforced concrete frames with wide beams mainly designed for gravity loads, as typically found in the seismic-prone Mediterranean area before the introduction of modern codes. The seismic capacity is evaluated in terms of the overall amount of input energy that the frame can dissipate/absorb up to collapse. This approach provides a quantitative evaluation that can be useful for selecting and designing an appropriate retrofit strategy. Six prototype frames representative of past construction practices in the southern part of Spain are designed, and the corresponding non-linear numerical models are developed and calibrated with purposely conducted tests on wide beam-column subassemblages. The models are subjected to sixteen earthquake records until collapse by applying the incremental dynamic analysis method. It is found that the ultimate energy dissipation capacity at the story level is markedly low (about 1.36 times the product of the lateral yield strength and yield displacement of the story), giving values for the maximum amount of energy that the frame can dissipate which are from one fourth to half of that required in moderate-seismicity regions.

석탄연소보일러 개조공사에 적용된 저NOx 미분탄 버너의 성능 평가 (Performance Evaluation of Low NOx Pulverized Coal Burner Applied in Coal Fired Boiler Refurbishment Project)

  • 김상현;송시홍;김혁제;김혁필
    • 한국연소학회지
    • /
    • 제11권4호
    • /
    • pp.22-26
    • /
    • 2006
  • To meet the environmental requirements, Doosan Heavy Industries & Construction Co., Ltd. (Doosan) had developed low NOx pulverized coal burner and it was applied to boiler retrofit project, 130 ton/hr coal fired cogeneration boiler, in 2003. NOx emissionand unburned carbon (UBC) in fly ash were measured during the commissioning tests. In this paper, the operation results of low NOx pulverized coal burner installed in 130 ton/hr coal fired boiler are presented. Burners emitted 160 ppm (@6 % $O_2$ basis) NOx and 3 % UBC with Chinacoal containing 0.86 % fuel nitrogen. And also it was shown that NOx emission rate of low NOx pulverized coal burner is linearly increased with fuel-nitrogen fraction of coal.

  • PDF

75 MWe급 중유 발전소 보일러에 대한 바이오중유 100% 전소 실증 연소실험 결과 (The Demonstration Test Result of 100% Bio Heavy Oil Combustion at the 75 MWe Oil Fired Power Plant)

  • 백세현;박호영;김영주;김태형;김현희;고성호
    • 한국연소학회지
    • /
    • 제19권2호
    • /
    • pp.28-36
    • /
    • 2014
  • Bio fuel oil combustion experiments were successfully demonstrated at the 75 MWe oil-fired power plant without major equipment retrofit and 100% bio-fuel oil combustion was possible without big problems. The experimental data error correction was conducted and numerical model-based analysis technique was applied for the evaluation of the results. Incase of bio fuel oil combustion, heat absorption of radiative heat transfer section was reduced while convection section has opposite trend. The furnace exit gas temperature tends to rise slightly. Environment emissions such as NOx and SOx concentrations showed a tendency to decrease during the bio fuel oil combustion period. On the other hand, boiler efficiency was slightly underestimated.

Long run ambient noise recording for a masonry medieval tower

  • Casciati, S.;Tento, A.;Marcellini, A.;Daminelli, R.
    • Smart Structures and Systems
    • /
    • 제14권3호
    • /
    • pp.367-376
    • /
    • 2014
  • Ambient vibration techniques are nowadays a very popular tool to assess dynamic properties of buildings. Due to its non destructive character, this method is particularly valuable, especially for health monitoring of historical monuments. The present ambient vibration experiment consists on the evaluation of vibration modes of a Medieval tower. Situated in Soncino (close to Cremona, in the Northern Italian region named Lombardia), the tower of 41.5 meters height has been monitored by seismometers located at different points inside the structure. Spectral ratios of the recorded ambient vibrations clearly identify a fundamental mode at about 1 Hz, with a slight difference in the two horizontal components. A second mode is also evidenced at approx 4-5 Hz, with a moderate degree of uncertainty. The records of a ML 4.4 earthquake, occurred during the monitoring period, confirm the information obtained by microtremor analysis. Daily variations of both 1st and 2nd mode were detected: these variations, of an amount up to 2%, seem to be well related with the temperature.

비내진 근린생활시설의 노후도를 고려한 내진성능평가 (Seismic Performance Evaluation of Nonseismic Neighborhood Living Facilities Considering Deterioration)

  • 이영천;정채명;이은진;김명훈;최기봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.55-63
    • /
    • 2013
  • 본 연구는 우리나라에서 가장 일반적인 중소규모의 비내진 상세를 가진 건축물을 대상으로, 노후도를 고려하여 내진성능을 평가하였다. 평가결과, 준공 후 24년이 경과되었으나 노후도는 대체로 양호한 것으로 평가되었고, 1차, 2차 내진성능평가는 기준지표를 만족하지 못하는 것으로 나타났다. 3차 내진성능평가에서는 층간변위비를 기준으로 목표성능은 만족하지만 보강이 필요한 것으로 판단되었다. 대상 건축물에 벽체보강, 가새보강, 댐퍼보강을 한 후 내진성능평가를 실시한 결과, 보강방법에 상관없이 층간변위비는 현저히 감소하여 즉시거주수준을 만족하는 수준으로 나타났다. 그러나 벽체보강의 경우 밑면전단력이 2배 이상 증가되어 기존기초에 대한 검토가 필요하다.

한국 조적조 건물의 내진성능 및 지진피해율 평가 (Earthquake Damae Ratio Estimation and Seismic Capacity Evaulation of Existing unreinforced masonry building in Korea)

  • 강대언;양원직;이원호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.258-265
    • /
    • 2005
  • The purpose of this study is to provide basic information for unreinforced masonry building in Korea by application of the proposed seismic evaluation method. In this study, seismic capacities of 50 existing unreinforced masonry buildings are evaluated based on the proposed method. Also, relationships of seismic capacities between Korean earthquake damage ratios of Korean unreinforced masonry buildings are estimated. Results of this study were as follows; 1)Seismic retrofit was needed $4{\sim}48%$ in Korean unreinforced masonry buildings. 2)Korean unreinforced masonry buildings were expected to have severe damage under the earthquake intensity level experienced in Japan.

  • PDF

Seismic Risk Assessment of Existing Low-rise Reinforced Concrete Buildings in Korea

  • LEE, Kang Seok;Jung, Ju-Seong;Choi, Yun-Chul
    • Architectural research
    • /
    • 제20권1호
    • /
    • pp.17-25
    • /
    • 2018
  • Countermeasures against earthquake disasters such as the seismic capacity evaluation and/or retrofit schemes of buildings, especially existing low-rise reinforced concrete buildings, have not been fully performed since Korea had not experienced many destructive earthquakes in the past. However, due to more than 1200 earthquakes with low or moderate intensity in the off-coastal and inland of Korea during the past 20 years, and due to the recent moderate earthquakes in Korea, such as the 2016 Gyeongju Earthquake with M=5.8 and the 2017 Pohang Earthquake with M=5.4, the importance of the future earthquake preparedness measures is highly recognized in Korea. The main objective of this study is to provide the basic information regarding seismic capacities of existing low-rise reinforced concrete buildings in Korea. In this paper, seismic capacities of 14 existing low-rise reinforced concrete public buildings in Korea are evaluated based on the Japanese Standard for Evaluation of Seismic Capacity of Existing Reinforced Concrete Buildings. Seismic capacities between existing buildings in Korea and those in Japan is compared, and the relationship of seismic vulnerability of Korean buildings and Japanese buildings damaged due to severe earthquakes are also discussed. Results indicated that Korean existing low-rise reinforced concrete buildings have a narrow distribution of seismic capacities and they are relatively lower than Japanese buildings, and are also expected to have severe damage under the earthquake intensity level experienced in Japan. It should be noted from the research results that the high ductility in Korean existing low-rise buildings obtained from the Japanese Standard may be overestimated, because most buildings investigated herein have the hoop spacing wider than 30 cm. In the future, the modification of strength and ductility indices in the Japanese Standard to propose the seismic capacity evaluation method of Korean buildings is most needed.

기존 도로교의 내진성능향상 방법 선정을 위한 가중치 평가기법 (Weighting-Factored Evaluation Method for Determination of Seismic Retrofitting Schemes for Existing Bridges)

  • 하동호;이지훈;박광순;이용재
    • 한국지진공학회논문집
    • /
    • 제11권3호
    • /
    • pp.43-52
    • /
    • 2007
  • 본 논문에서는 기존 도로교의 합리적이고 일관적인 내진성능향상 방법 선정을 위한 가중치 평가기법을 제안하였다. 한반도의 증가하는 지진위험도를 반영하여, 현재 기존교량의 내진성능향상 작업이 다양한 공법을 이용하여 진행 중이나 최적의 공법을 선정하기 위한 적절한 판단기준이 부재한 형편이다. 이에 제안한 기존가중치 평가기법은 구조적 적합성, 경제성, 환경적 영향, 시공성, 유지관리 측면의 다섯 가지 영향인자의 가중치를 부여하여 최적의 내진 보강방안을 선정하는 방법이다. 제안된 가중치 평가기법을 공용중인 도로교 160개교에 적용한 결과 최고점수는 실제 최종 보강방안과 대부분 일치하여 적절한 가중치로 설정되었다고 판단된다. 제안하는 방법을 기존교량의 내진 보강방안 선정 시에 활용한다면, 사회적 비용을 최소화하는 보다 합리적이고 일관적인 보강이 가능할 것이다.