• Title/Summary/Keyword: evacuation routes

Search Result 90, Processing Time 0.02 seconds

Betweenness Centrality-based Evacuation Vulnerability Analysis for Subway Stations: Case Study on Gwanggyo Central Station (매개 중심성 기반 지하철 역사 재난 대피 취약성 분석: 광교중앙역 사례연구)

  • Jeong, Ji Won;Ahn, Seungjun;Yoo, Min-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.407-416
    • /
    • 2024
  • Over the past 20 years, there has been a rapid increase in the number and size of subway stations and underground structures worldwide, and the importance of safety for subway users has also continuously grown. Subway stations, due to their structural characteristics, have limited visibility and escape routes in disaster situations, posing a high risk of human casualties and economic losses. Therefore, an analysis of disaster vulnerabilities is essential not only for existing subway systems but also for deep underground facilities like GTX. This paper presents a case study applying a betweenness centrality-based disaster vulnerability analysis framework to the case of Gwanggyo Central Station. The analysis of Gwanggyo Central Station's base model and various disaster scenarios revealed that the betweenness centrality distribution is symmetrical, following the symmetrical spatial structure of the station, with high centrality concentrated in the central areas of basement levels one and two. These areas exhibited values more than 220% above the average, indicating a high likelihood of bottleneck phenomena during evacuation in disaster situations. To mitigate this vulnerability, scenarios were proposed to distribute evacuation flows concentrated in the central areas, enhancing the usability of peripheral areas as evacuation routes by connecting staircases continuously. This modification, when considered, showed a decrease in centrality concentration, confirming that the proposed addition of evacuation paths could effectively contribute to dispersing the flow of evacuation in Gwanggyo Central Station. This case study demonstrates the effectiveness of the proposed framework for assessing evacuation vulnerability in enhancing subway station user safety and can be effectively applied in disaster response and management plans for major underground facilities.

A Proposal on Evacuation Safety in Medical Welfare Facilities for the Elderly: Targeting the Goyang City (노인의료복지시설의 피난안전에 대한 제언: 고양시를 대상으로)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.52-58
    • /
    • 2020
  • The number of medical welfare facilities caring for the elderly with paralysis and dementia has been increasing rapidly because of the change in the way of supporting the elderly, stemming from an increase in the number of the elderly and working couples. These medical welfare facilities are usually installed all over the city and are gradually becoming high-rise. Few inmates are capable of making their own decisions in case of fire at night and when there are no escape routes such as ramps for evacuation, leading to massive casualties. This study aimed to identify problems in evacuation in the medical welfare facilities for the elderly in Goyang city. This city has the largest number of medical welfare facilities for the elderly per unit area. The following strategies could aid in better evacuation: secure ramps or bed escape elevators; the bedrooms of the inmates should have one-hour fire resistance; the stairs should have the structure of an enclosed stairway; the necessary apparatus for evacuation, such as an escape chute, should be installed; and, to conclude, a business agreement with neighboring agencies to help inmates escape during the fire. The state should implement necessary measures to protect the lives and property of the people. Rapid implementation of this proposal is necessary for the evacuation safety of an increasing number of medical welfare facilities for the elderly.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Influence of the Fire on Emergency Evacuation Support System (대공간용 비상피난지원 시스템에 화재가 미치는 영향 분석)

  • Kim, JiTae;Sung, Kun Hyuk;Park, Won Hee;Lee, Duck Hee;Woo, Jun You;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.626-631
    • /
    • 2018
  • An emergency evacuation support system is used to maintain evacuation routes by pressurizing a space inside screens. In cases of fire, it is important to understand the thermal distributions in the tunnel for preventing system failure. In this study, we numerically investigated the effect of fire on an emergency evacuation support system in a large fabric store with some fire scenarios with different combustibles. The critical temperature for system failures was assumed to be $200^{\circ}C$. As a result, the highest temperature was predicted in the ceiling part due to the effect of a ceiling jet, and the fire safety of the screen was secured at distances of 20 to 30 m according to the heat release rate. To prevent the inflow of smoke into the system, it is necessary to maintain more than 5 Pa if positive pressure inside the smoke screen. The results of this study could be useful for designing an emergency evacuation support system.

A Study on the Risk Assessment of the Underground Space -The Estimation of Smoke Reservoir Screen for Smoke Control in Subway Station Platform (지하공간의 위험성평가에 관한 연구 -지하철 역사내의 연기제어를 위한 제연경계벽의 효용성 평가)

  • Roh Sam-Kew;Hur Jun-Ho
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.103-109
    • /
    • 2004
  • The risk of underground space become an important issue of life safety thought the Taeku subway line Accident. It is essential to study of smoke control screen to minimize the damage of human life because of smoke passage and passenger evacuation routes are on the same vertical and dispersion movement. The Fire modeling result shows the effect of fire control screen can save the evacuation time about 2-2.5 times compare to existing the system However, The designs of fire control screen need to be complied with smoke control ventilation system to present optimum design and the position of installation.

Smart Escape Support System for Passenger Ship : Active Dynamic Signage & Real-time Escape Routing (능동형 피난유도기기와 실시간 피난경로생성 기술을 적용한 여객선 스마트 인명대피 시스템)

  • Choi, James;Yang, Chan-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.79-85
    • /
    • 2017
  • It is critical that passengers should be given timely and correct escape or evacuation guidance from captain and crews when there are hazardous situations in a ship. Otherwise the consequences could be disastrous as "SEWOL Ferry" the South Korean passenger ship which sank in southern coastal area on 16th April 2014. Due to the captain's delayed evacuation decision and lack of sufficient number of crews to guide passengers' evacuation, the accident recorded many casualties, most of whom were high school students (302 passengers sank down with the ship while 172 rescued). Building a passenger ship with well-designed physical escape routes is one thing and guiding passengers to those escape routes in real disaster situation is another. Passengers get panic and move to a wrong direction, bottleneck makes situation worse, and even crews get panic also - passive static escape route signage and small number of trained crews might not be enough to take care of them. SESS (Smart Escape Support System) is being developed sponsored by South Korea Ministry of Ocean and Fisheries starting from 2016 with 4 years of roadmap. SESS comprises multiple active dynamic signage devices which communicate with real-time escape routing server software via LoRa (Long Range) proprietary wireless network.

  • PDF

Evaluation of Civil Defense Evacuation Shelter Locations in Fitness according to the Walking Speed and Changing Floating Population in Time and Space (시공간 유동인구 변화와 보행속도에 따른 민방위 비상 대피시설 위치의 적절성 평가)

  • Park, Jae-Kook
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.95-103
    • /
    • 2018
  • This study set out to evaluate the fitness of shelter locations by taking into consideration service zones according to walking speed, the changing population between day and night, and walking routes. Walking speed was defined as 1.6 m/s, 2 m/s based on the cases of previous studies. The changing population between day and night was estimated with the dasymetric mapping technique. Shelter service zones according to walking speed and routes were analyzed with the network of the location allocation model. The findings show some shelters had limits with their capacity according to the changing floating population and walking speed in time and space and raise a need to appoint additional shelters.

The Effective Third Circulation Plan Based on Elevator and Escalator Users Surveys in Mixed-Use Buildings (복합건축의 수직동선 이용자별 효율적인 제3동선의 설정)

  • Lee, Jin-Kyoung;Kim, Chan-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.2
    • /
    • pp.3-10
    • /
    • 2019
  • The purpose of the study is to survey the effective methodology of composition and connection for the third pedestrian routes in mixed-use building by case studies. The study is performed as follows: First of all, pedestrian routes are classified into malling route, evacuation route, and the Third route. Secondly, case studies are conducted based on the classification. Thirdly, it is investigated about the composition and connection of the malling and the Third pedestrian route. The investigation is focused on gate, path, central area, vertical circulation(EV and escalator) and the four circulation elements. Finally, the effective methodology is extracted for setting the Third route in mixed-use buildings. The conclusion of the study is as follows: The enhancement of consistency and connection between the main route and the Third route is important for providing convenient paths especially to users who needs shortcut, EV/ES users. Additionally, the connections between EV and gate, between shortcut and EV/ES should be increased to enable users choosing their path as needed.

Development of an Open Source-based Spatial Analysis Tool for Storm and Flood Damage (풍수해 대비 오픈소스 기반 공간분석 도구 개발)

  • Kim, Minjun;Lee, Changgyu;Hwang, Suyeon;Ham, Jungsoo;Choi, Jinmu
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_3
    • /
    • pp.1435-1446
    • /
    • 2021
  • Wind and flood damage caused by typhoons causes a lot of damage to the Korean Peninsula every year. In order to minimize damage, a preliminary analysis of damage estimation and evacuation routes is required for rapid decision-making. This study attempted to develop an analysis module that can provide necessary information according to the disaster stage. For use in the preparation stage, A function to check past typhoon routes and past damage information similar to typhoon routes heading north, a function to extract isolated dangerous areas, and a function to extract reservoir collapse areas were developed. For use in the early stages of response and recovery, a function to extract the expected flooding range considering the current flooding depth, a function to analyze expected damage information on population, buildings, farmland, and a function to provide evacuation information were included. In addition, an automated web map creation method was proposed to express the analysis results. The analysis function was developed and modularized based on Python open source, and the web display function was implemented based on JavaScript. The tools developed in this study are expected to be efficiently used for rapid decision-making in the early stages of monitoring against storm and flood damage.

A Study on Introduction of Student Volunteer Fire Department in Dormitory far from Fire Station (근접성이 불리한 대학 기숙사의 학생 의용소방대 도입에 관한 연구)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.65-69
    • /
    • 2015
  • The university dormitory have various functions and large floating population so in the occurrence of fire, there could be heavy casualties. Also, when university dormitory is located far from fire station, it is difficult to fire brigade arrives on Golden Time. Therefore, university dormitory need response capabilities for fire by itself. This study conducted a simulation experiment on those residing in K University dormitory in Gangwon-do, where site proximity is unfavorable, to observe evacuation characteristics of the occupants. As a result, evacuation is delayed due to a lack of evacuation routes and administrator, some students lack of fire awareness. Also fire brigade didn't arrive on Golden Time. Therefore, to resolve problems it is proposed that a student fire volunteer department.