• Title/Summary/Keyword: escape stair

Search Result 10, Processing Time 0.019 seconds

A Study on Human Behavioral Pattern and the Design of Escape Stair (인간행동습성과 피난계단의 설계에 관한 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.3-12
    • /
    • 1998
  • The purpose of this study is to examine that the escape stair of high-rise buildings has to be designed as a left-handed stair(a stair being designed to turn left whicle we go down the ground floor) judging from fire-safety point of view. Most of Korean people are right-handers. In case of right-handers it was found that the occupant's escape speed using a left-handed stair is more convenient and fast than of a right-handed stair(a stair being designed to turn right while we go down the ground floor). But most of the escape stair of high-rise buildings in Korea was designed as a right-handed stair. The fire code therefore should be provided that the escape stair of high-rise buildings should be a left-handed stair.

  • PDF

A Study on the Actual Smoke Exhaust Condition and Improvement Program of Special Escape Stair (건축물 특별피난계단의 배연 실태 및 개선방안에 관한 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Kim, Jung-Yup;Shim, Kyu-Hyung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.286-289
    • /
    • 2008
  • In this study, we have survey of the actual smoke exhaust condition and improvement program in special escape stair. We have collected and analysed the survey view take 50 professional advice. Domestic a technical and legal standard is rated as compared with an advanced countries to $40{\sim}60%$. Hazard must be improved a security with the evacuation where the standard of present time is safe the reply with 64% to appear it was analyzed with the fact that the improvement which it follows hereupon is necessary.

  • PDF

A Study on Performance Improvement Measures of Pressurized Smoke Control Systems for Exit Passageways of High-Rise Buildings (고층건축물의 피난경로 가압제연시스템 성능개선대책에 관한 연구)

  • Son, Bong-Sae;Kim, Jin-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.703-714
    • /
    • 2009
  • One of the biggest problems in smoke control systems for high-rise buildings is stack effect, but there are no recognized methods or measures to solve the problem of stack effect as yet. The stack effect can be overcome by forming the uprising current inside the stair hall properly, but there is a limit to the height in supplying into the stair hall the smoke control air volume to be supplied to a floor in case of escape from fire. The limit to the height can be extended by over-coming the stack effect by pressurizing the stair hall and the ancillary room simultaneously. It can also be anticipated that the stack effect can be overcome by connecting the air supply shaft to the stair hall at the top. As a result of computer simulations using a network type of tool, it is found that adequate performance can be achieved by pressurizing the stair hall only for a building of 190m or less, and up to 360m when pressurizing the stair hall and the ancillary room simultaneously. In all those cases, however, an overpressure venting damper is required which operates within a suitable range for venting the overpressure outside.

The Improvement of Evacuation Performance for Discount-Store in Underground (할인점 지하매장의 피난성능 개선에 관한 연구)

  • 김영일;윤명오;김종훈;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2001
  • This study aims to improve the Evacuation Performance o( the I)inc()unto-store in underground that is rapidly new shopping store in Korea. In this paper, The architectural properties of the floor plan and section was reviewed with egress focus, occupant load density of the Discount-store was surveyed and the procedure and method of performance based egress design for this occupancy was analysed with SIMULEX model and calculation method. As a result of modeling, more longer available safe egress time (ASET) is expected than required safe egress time (RSET)in underground discount-store. In order to improve the Evacuation Performance for this type occupancy, egress capacity including escape stair, aisle width, escape door is calculated with based on occupant load density and review of shopping cart's structure and size and maximum escape capacity of the cash counter.

  • PDF

Field Experiments on Stack Effect in Stairwells of High-Rise Building (고층건물 피난계단에서의 연돌효과에 대한 현장실험)

  • Kim, Jung-Yup
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.459-462
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The architectural factors affecting the pressure field of building should be examined for the successful design and operation of smoke management system and the stack effect is one of the important factors. The field experiments on stack effect in stairwells of high-rise building with regard to open/close condition of door are carried out to evaluate the features of pressure applied to door between each compartments, i.e, stair, lobby and accommodation. The procedures and results of experiments are presented.

  • PDF

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

The Study of Outflow Rate of Stair and Turnstile in Subway Station - Comparison between Measurement and Simulation (지하철 역사에서 개찰구 및 계단 유출특성에 관한 연구 - 실측과 시뮬레이션의 비교)

  • Kim, Eung-Sik;Cho, Ju-Ho;Kim, Myeoung-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.33-38
    • /
    • 2010
  • Recently commercial egress softwares are frequently used for the risk assessment. The estimation of evacuation time is an important procedure and the outflow coefficient in a bottleneck becomes the crucial factor for design of emergency planning. This paper compares the outflow coefficient of measurement with those of softwares in the bottlenecks of subway stations where masses of people movement is observed. Stairway and turnstile are the 2 bottleneck points along escape pathway. For the escape simulation it is recommended that 2 different modes be used in the programs for 2 kinds of bottleneck. The results of the comparison makes a big difference among them and some of differences can be reduced by correct design of input data. In conclusion the results of simulation should be examined thoroughly by procedure of comparisons with other results.

A Study on Comparison and Shortening of Evacuation Time Required of University Library by Simulation (시뮬레이션을 통한 대학도서관의 피난 소요시간 비교 관한 연구)

  • An, Jeong-Pill;Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.10-18
    • /
    • 2017
  • The University library is a reality where facilities can be a massive upset by the space of students to study space and book materials. Also, many print materials can cause fires quickly in fires, resulting in massive amounts of human casualties caused by many toxic gases. This study purpose is compares the time spent in the evacuation of the current state through the simulation, which seeks to derive a reasonable library of evacuation design, and improved inside the evacuation. As a result, the most obvious way to reduce the time required to evacuate is to diversify the evacuation routes and to disperse them. However, if the extension of the gate is not feasible, it is possible to reduce the time of escape by increasing the width of the gate and the width of the stair. If the results of this study are applied to new construction or remodeling of the library and prepare for fire evacuation, it will be a much safer library facility.

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.