• Title/Summary/Keyword: error check

Search Result 625, Processing Time 0.028 seconds

A Study on Korea Land Use Information System Zoning Data Maintenance Plan (국토이용정보체계 용도지역지구 데이터 정비방안)

  • Lee, Se-won
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.51-72
    • /
    • 2021
  • The purpose of this study is to explain the types and causes of errors in zoning data that occur in the topographic map notification procedure, and to prepare a data maintenance plan. In Korea, like the United States, law-based land use regulation is dominant. In other words, according to the land use regulation method in the Act, the government designates zoning for all lots in the country, and landowners check the land use regulations of their land through the Korea Land use Information System. The land use plan confirmation document is important land information that affects the results of administrative dispositions such as land transactions between individuals or permission for development activities. However, there are data errors that occur during the current topographic map notification procedure and data construction process. Therefore, four local governments that can verify data by type were selected in consideration of local government conditions. A number of errors are first, errors in data construction and management in the Korea Land use Information System, and second, errors in lack of expertise that occur while the local government officials maintain data. Third, it was analyzed as an error from the relationship between the serial cadastral map and the zoning DB. Based on the above results, it is hoped that the results of this study will be reflected in the establishment of the KLIP and the reform of the legal system, which is currently underway after the establishment of the 「3rd the Korea Land use Information System Construction Plan」.

Scale Effect Analysis of LNG Cargo Containment System Using a Thermal Resistance Network Model (열저항 네트워크 모델을 이용한 LNG 화물창 Scale Effect 분석)

  • Hwalong You;Taehoon Kim;Changhyun Kim;Minchang Kim;Myungbae Kim;Yong-Shik Han;Le-Duy Nguyen;Kyungyul Chung;Byung-Il Choi;Kyu Hyung Do
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.222-230
    • /
    • 2023
  • In the present work, the scale effect on the Boil-Off Rate (BOR) was investigated based on an analytical method to systematically evaluate the thermal performance of a Liquefied Natural Gas (LNG) Cargo Containment System (CCS). A two-dimensional thermal resistance network model was developed to accurately estimate the heat ingress into the CCS from the outside. The analysis was performed for the KC-1 LNG membrane tank under the IGC and USCG design conditions. The ballast compartment of both the LNG tank and cofferdam was divided into six sections and a thermal resistance network model was made for each section. To check the validity of the developed model, the analysis results were compared with those from existing literature. It was shown that the BOR values under the IGC and USCG design conditions were agreed well with previous numerical results with a maximum error of 1.03% and 0.60%, respectively. A SDR, the scale factor of the LNG CCS was introduced and the BOR, air temperature of the ballast compartment, and the surface temperature of the inner hull were obtained to examine the influence of the SDR on the thermal performance. Finally, a correlation for the BOR was proposed, which could be expressed as a simple formula inversely proportional to the SDR. The proposed correlation could be utilized for predicting the BOR of a full-scale LNG tank based on the BOR measurement data of lab-scale model tanks.

Prediction of Microstructure and Hardness of the Ductile Cast Iron Heat-treated at the Intercritical Temperatures (임계간 온도에서 열처리한 구상흑연주철의 미세조직 및 경도 예측)

  • Nam-Hyuk Seo;Jun-Hyub Jeon;Soo-Yeong Song;Jong-Soo Kim;Min-Su Kim
    • Journal of Korea Foundry Society
    • /
    • v.43 no.6
    • /
    • pp.279-285
    • /
    • 2023
  • In order to predict the mechanical properties of ductile cast iron heat treated in an intercritical temperature range, samples machined from cast iron with a tensile strength of 450 MPa were heat-treated at various intercritical temperatures and air-cooled, after which a microstructural analysis and Brinell hardness test were conducted. As the heat treatment temperature was increased in the intercritical temperature range, the ferrite fraction in the ductile cast iron decreased and the pearlite fraction increased, whereas the nodularity and nodule count did not change considerably from the corresponding values in the as-cast condition. The Brinell hardness values of the heat-treated ductile cast iron increased gradually as the heat treatment temperature was increased. Based on the measured alloy composition, the fraction of each stable phase and the hardness model from the literature, the hardness of the ductile cast iron heat treated in the intercritical temperature range was calculated, showing values very similar to the measured hardness data. In order to check whether it is possible to predict the hardness of heat-treated ductile cast iron by using the phase fraction obtained from thermodynamic calculations, the volumes of graphite, ferrite, and austenite in the alloy were calculated for each temperature condition. Those volume fractions were then converted into areas of each phase for hardness prediction of the heat-treated ductile cast iron. The hardness values of the cast iron samples based on thermodynamic calculations and on the hardness prediction model were similar within an error range up to 27 compared to the measured hardness data.

Receiving System Design of ILS Navigation Signal Using SDR (SDR을 이용한 ILS 항행신호 수신 시스템 설계)

  • Minsung Kim;Ji-hye Kang;Kyung Heon Koo;Kyung-Soon Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.3
    • /
    • pp.254-261
    • /
    • 2024
  • Accurate guidance during landing and take-off is important, and instrument landing system (ILS) has been used for stability and verification. Regular inspections are conducted for stable operation, and there is research to perform inspection using drones in addition to ground vehicles and measurement aircraft. Using SDR and single board computer, which can receive wide frequency range, we designed a small system that receives and processes localizer signals through GNU Radio. To check signal processing characteristics through GNU Radio, we simulated with MATLAB Simulink and confirmed the theoretical values. Difference in depth of modulation (DDM) and approach angle can be calculated when the aircraft enters the runway. And GNU Radio implemented real-time signal processing wirelessly using transmission control protocol (TCP). This gives the results within the error of 0.5% when the aircraft entered the runway center line and 0.27% for the angle of 1° degree. Compared to the inspecting and maintaining ILS signals using aircraft or ground vehicles, it is possible to implement a receiving system using small SDR that can be mounted for drone.

An application of MMS in precise inspection for safety and diagnosis of road tunnel (도로터널에서 MMS를 이용한 정밀안전진단 적용 사례)

  • Jinho Choo;Sejun Park;Dong-Seok Kim;Eun-Chul Noh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.2
    • /
    • pp.113-128
    • /
    • 2024
  • Items of road tunnel PISD (Precise Inspection for Safety and Diagnosis) were reviewed and analyzed using newly enhanced MMS (Mobile Mapping System) technology. Possible items with MMS can be visual inspection, survey and non-destructive test, structural analysis, and maintenance plan. The resolution of 3D point cloud decreased when the vehicle speed of MMS is too fast while the calibration error increased when it is too slow. The speed measurement of 50 km/h is determined to be effective in this study. Although image resolution by MMS has a limit to evaluating the width of crack with high precision, it can be used as data to identify the status of facilities in the tunnel and determine whether they meet disaster prevention management code of tunnel. 3D point cloud with MMS can be applicable for matching of cross-section and also possible for the variation of longitudinal survey, which can intuitively check vehicle clearance throughout the road tunnel. Compared with the measurement of current PISD, number of test and location of survey is randomly sampled, the continuous measurement with MMS for environment condition can be effective and meaningful for precise estimation in various analysis.

A Study on the Applicability of the Crack Measurement Digital Data Graphics Program for Field Investigations of Buildings Adjacent to Construction Sites (건설 현장 인접 건물의 현장 조사를 위한 균열 측정 디지털 데이터 그래픽 프로그램 적용 가능성에 관한 연구)

  • Ui-In Jung;Bong-Joo Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.63-71
    • /
    • 2024
  • Through the development of construction technology, various construction projects such as redevelopment projects, undergrounding of roads, expansion of subways, and metro railways are being carried out. However, this has led to an increase in the number of construction projects in existing urban centers and neighborhoods, resulting in an increase in the number of damages and disputes between neighboring buildings and residents, as well as an increase in safety accidents due to the aging of existing buildings. In this study, digital data was applied to a graphics program to objectify the progress of cracks by comparing the creation of cracks and the increase in length and width through photographic images and presenting the degree of cracks numerically. Through the application of the program, the error caused by the subjective judgment of crack change, which was mentioned as a shortcoming of the existing field survey, was solved. It is expected that the program can be used universally in the building diagnosis process by improving its reliability if supplemented and improved in the process of use. As a follow-up study, it is necessary to apply the extraction algorithm of the digital graphic data program to calculate the length and width of the crack by itself without human intervention in the preprocessing work and to check the overall change of the building.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

The Study on the investigation of oriental medical theraphy(oriental medical theraphy by symptoms and signs and Sasang constitutional medicine)and the each effect of oriental medicine, occidental medicine and both joint control (뇌졸중(腦卒中)에 대(大)한 한방치료법(韓方治療法) 연구(硏究)(증치의학(證治醫學)과 사상의학(四象醫學)) 및 한방(韓方), 양방(洋方), 양(洋)·한방(韓方) 협진치료(協診治療) 효과(效果)에 관(關)한 연구(硏究))

  • Kim, Jong-won;Kim, Young-kyun;Kim, Beob-young;Lee, In-seon;Lee, In-seon;Jang, Kyung-jeon;Gwon, Jeong-Nam;Lee, Won-oe;Song, Chang-won;Park, Dong-il
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.351-429
    • /
    • 1998
  • The Purpose of Study 1. Inspection of clinical application on TCD to CVA 2. Objective Comparement and analysis about treatment effect of Western-Medicine, Korean Medicine, Cooperative consultation of Korean and Western medicice for CVA The Subject of Study We intended for the eighty six patient of CVA who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center from 1997. 8. I to 1998. 7. 31 1. View of CT, MRI : the patient of Cb infarction 2. Attack Time : The patient who coming hospital falling ill within the early one week The method of study 1. Treat four group of Korean medicine, Constitution medicine, Western medicine, cooperative consultation of Korean medicine and Western medicine. 2. Application of TCD Check the result for three times, immediatly after the attack, two months later, four months later 3. Comparative analysis of each treatment effect by clinical symptoms and pathologic examination 4. The Judgement of the patient The Result From 8/1/1997 to 7/31/1998, We have the following result by clinical analysis intended for CVA 86 patients who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center from 1997. 8. 1 to 1998. 7. 31 in 1. Analysis according to Age The first stage of thirties, forties, seventies is heavier than forties, fifties in improvement and Index of improvement of symptom 2. Analysis according to sex We have no special relation in an average of symptom and improvement, Index improvement 3. Analysis according to Family History We have the better result in first stage and improvement, index improvement when no family history. 4. Analysis according to Past History We have no special relation in past history like hypertension, DM, heart problem 5. Analysis devided two group, above group and under group on the basis of the average in first stage of all patient. We have the better result when the first stage is light, that the first score of barthel index and CNS is high. 6. Analysis of the effect of treatment about Korean medical treatment, Western medical treatment, cooperative treatment. In this study, the highest group of rate of treatment at four contrast groups (Korean medicine, Constitution medicine, Western medicine, cooperative treatment according to dyagnosis and range of treatment was the patient group of doing dyagnosis and method of treatment based on constitution medicine theory. This is that of doing demostation, A-Tx, po-herb-medication according to dyagnosis and treat method of constitution of Lee Je-ma In case of left, the case of dyagnosis any disease according to doctor view but, normal in TCDwas 22-beginning of attack, 20- two weeks later, 11 case-four weeks later in case of right, 15-beginning of attack, 12-two weeks later, 9 case four weeks later. So left vessel compares to right vessel is more interference, in fact more than a 1/2 of the patients of MCA disease can't do dyagnosis. In rate of imparement, the state of pacient improved but there isn't the improved case of result in TCD. 7. In TCD dyagnosis, between the case of inconsus the doctor view specially MCA in brain blood vessel is in large numbers and in total 86's patient, impossible case of dyagnosis according to interferiance of temporal is 21 case. 7. Result study about application of Kreaan medical treatment 1) The impossible patient of observation MCA blood vescular for interference temporal bone happened in large numbers. 2) There is the case having difference result to CT,MRI, MRA result. 3) Because individual difference is large, excluding to ananalogy of symptom. This is normal numerical value that has possibility of being checked as abnormal numerical value 4) there are a lot of cases that the speed of normal part is as similarly measured as that of abnormal part. It means that we cannot judge the disease by this measure 5) It is rare that this measure represent degree of improvement in patient's condition of disease. When we observe patient's condition become better, but we have no case that the result of TCD test better. 6) The result could be appear differently by the technique of the tester or by the experience of the tester 7) In the TCD test, abnormal symptoms is checked at 0 week, but at 2th week, normal symptoms is checked, again at 4th week abnormal is checked. According to the above result, CVA diagnosis is difficult only with TCD, as it appear in diagnosis error check which is suggested in the problem connected to project, for the aged persons who have the worst hardening of part of the cranium (1998. 5. 26 77 of 83 patients is 50s) there is a lot of cases that the measurement is impossible by TCD and the correction of measurement numerical value is decreased, as the age of cerebral infarction is high, TCD is inappropriate to diagnosis equipment through this study.

  • PDF

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF