• Title/Summary/Keyword: equivalent length

Search Result 597, Processing Time 0.028 seconds

Investigation on the Perception of Mandatory Clinical Practice in the Department of Radiology Following the Amendment of the Medical Technologists Act (의료기사 등에 관한 법률 개정으로 방사선(학)과 현장실습 의무화에 따른 인식 조사)

  • Jeong-Mu Lee;Yong-Ki Lee;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.293-300
    • /
    • 2024
  • On October 31, 2023, the revision of the Medical Technologist Act made it mandatory to complete field training courses in order to obtain a license as a radiologic technologist. Therefore, we would like to survey the actual situation of field training in medical institutions to inform the revised Medical Technologist Act and propose improvement measures to increase the effectiveness of field training. A survey was conducted from March to April, 2023, among radiologic technologists working in medical institutions. The questionnaire was sent through a form on a domestic portal site, Company N, and 120 respondents completed it. Eighty-two respondents, or 68.3 percent, had experience in educating on-the-job training students. 58% of the respondents were aware of the fact that the amendment to the Act on Medical Technologist etc. made field training mandatory to obtain a radiologic technologist license. In accordance with Article 9 of the Medical Technologist Act, which prohibits unlicensed persons from practicing, 50% of the respondents were aware that those who are in training to complete an education course equivalent to the license they are seeking to obtain at a university or other institution are allowed to practice as medical Technologists. When asked what is currently taught during fieldwork, 6% of respondents said that they are required to perform radiation-generating activities in addition to observing, guiding patients, and positioning and moving patients. When asked about the future direction of education as fieldwork becomes mandatory for licensure, 77% of respondents said that they will teach more than they currently do. When asked about the appropriate total length of fieldwork, 35% said 12 weeks and 480 hours, 33% said 8 weeks and 320 hours, and 27% said 16 weeks and 640 hours. It can be seen that the current on-the-job training is inadequate according to various regulations, and students' satisfaction is low. However, with the revision of the Act on Medical Technologists, field training has become mandatory to obtain a license as a radiologist, and it is necessary to improve the educational conditions of field training. Therefore, it is necessary to comply with the Nuclear Safety Act and the Rules on the Safety Management of Diagnostic Radiation Generating Devices, introduce standardized training objectives and evaluation systems, designate training hospitals and radiologists in charge of training, and introduce extended training periods and simulation exercises to internalize field training.

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF

Fish Stock Assessment by Hydroacoustic Methods and its Applications - I - Estimation of Fish School Target Strength - (음향에 의한 어족생물의 자원조사 연구 - I - 어군반사강도의 추정 -)

  • Lee, Dae-Jae;Shin, Hyeong-Il;Shin, Hyong-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.142-152
    • /
    • 1995
  • The combined bottom trawl and hydroacoustic survey was conducted by using the training ship Oshoro Maru belong to Hokkaido University in November 1989-1992 and the training ship Nagasaki Maru belong to Nagasaki University in April 1994 in the East China Sea, respectively. The aim of the investigations was to collect the target strength data of fish school in relation to the biomass estimation of fish in the survey area. The hydroacoustic survey was performed by using the scientific echo sounder system operating at three frequencies of 25, 50 and 100kHz with a microcomputer-based echo integrator. Fish samples were collected by bottom trawling and during the trawl surveys, the openings of otter board and net mouth were measured. The target strength of fish school was estimated from the relationship between the volume back scattering strength for the depth strata of bottom trawling and the weight per unit volume of trawl catches. A portion of the trawl catches preserved in frozon condition on board, the target strength measurements for the defrosted samples of ten species were conducted in the laboratory tank, and the relationship between target strength and fish weight was examined. In order to investigate the effect of swimbladder on target strength, the volume of the swimbladder of white croaker, Argyrosomus argentatus, sampled by bottom trawling was measured by directly removing the gas in the swimbladder with a syringe on board. The results obtained can be summarized as follows: 1.The relationship between the mean volume back scattering strength (, dB) for the depth strata of trawl hauls and the weight(C, $kg/\textrm{m}^3$) per unit volume of trawl catches were expressed by the following equations : 25kHz : = - 29.8+10Log(C) 50kHz : = - 32.4+10Log(C) 100kHz : = - 31.7+10Log(C) The mean target strength estimates for three frequencies of 25, 50 and 100 kHz derived from these equations were -29.8dB/kg, -32.4dB/kg and -31.7dB/kg, respectively. 2. The relationship between target strength and body weight for the fish samples of ten species collected by trawl surveys were expressed by the following equations : 25kHz : TS = - 34.0+10Log($W^{\frac{2}{3}}$) 100kHz : TS = - 37.8+10Log($W^{\frac{2}{3}}$) The mean target strength estimates for two frequencies of 25 and 100 kHz derived from these equations were -34.0dB/kg, -37.8dB/kg, respectively. 3. The representative target strength values for demersal fish populations of the East China Sea at two frequencies of 25 and 100 kHz were estimated to be -31.4dB/kg, -33.8dB/kg, respectively. 4. The ratio of the equivalent radius of swimbladder to body length of white croaker was 0.089 and the volume of swimbladder was estimated to be approximately 10% of total body volume.

  • PDF

Studies of the Properties of Commercial Woods Grown in the Southern Part of Korea (한국산(韓國産) 유용목재(有用木材)의 기초재질(基礎材質)에 관(關)한 연구(硏究))

  • Chung, Byung-Jae;Lee, Jyung-Seuk;Kim, Yoon-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.3-19
    • /
    • 1978
  • Five species, Abies koreana Wilson (A. koreana), Castanopsis cuspidata var. Sieboldii Nakai (C. Cuspidata). Machilus thunbergii Sieb. et Zucc. (M. thunbergii), Styrax japonica (S. japonica), and Quercus acuta Thunberg(Q. acuta) growing in the southern part of Korea were selected for the investigation of wood properties. In order to evaluate the wood properties of these five species, anatomical, physical, mechanical, chemical and pulping characteristics were investigated. And this study also covered wood technological problems related to the drying, gluing, debarking, flooring, and wood workability so that these species might serve to the best advantage. The results obtained were summarized as follows: 1. The trunk of A. koreana with many knots was straight. However, the trunks of S. japonica and C. cuspidata were crooked. 2. A. koreana showed the longest and the widest ill the fiber morphology; 2.97mm in length, 39.3${\mu}$ in width. In general, fiber width of all the species investigated were greater than those of other Korean hardwoods. 3. The specific gravity of Q. acuta was 0.74${\pm}$0.03, and that of A.koreana was 0.34${\pm}$0.02. The range of specific gravity of the other species was 0.47-0.52. 4. The adsorption of water was propotioned inversely with the specific gravity, but the adsorption of humidity was proportioned with the specific gravity. In spite of their medium density, S. japonica showed the greatest adsorption, and M. thunbergii the least. The water adsorption of cross section was twice greater than that of lateral direction, and there was a slight difference in between the radial and the tangential direction. 5. Shrinkage for tested five species was ranged from 5.36 to 10.24% in tangential direction, and 2.83~6.13% in radial direction. Q. acuta recorded the greatest shrinkage rate, and A. koreana the least. The greater was the specific gravity, the larger was the shrinkage rate. 6. The mechanical properties of Q. acuta were similar to those of Quercus mongolica which grow in Kangwon-Do. Strength properties of C. cuspidata, M. thunbergii, A. koreana were equivalent to those of other Korean commercial woods with similar specific gravity, except S. japonica which showed slightly higher strength than that of other species with similar density. 7. Higher glue joint strength for urea and phenol adhesieves was recorded in the species of M. thunbergii and C. cuspidata, however, high-density species(Q. acuta) and even low-density species(A. koreana) did not show good joint strength. 8. The attractive figure of M. thunbergii in texture seemed to he appreciated for decoration. And the grain and texture of other species were proper for furniture and building materials. 9. All of the species except Q. acuta were considered good for wood workability. 10. The denser the specific gravity was, the longer the drying time took. However, severe drying defects were formed in M. thunbergii whose density was medium. 11. All the species were considered suitable for the flooring wood expect A. koreana whose density was light. 12. Pentosan component in all the species was great, and the amount of extractives in Q. acuta was worth noticing. 13. Yield in kraft pulp was above the level of economic pulp yield, i.e. 45% in all species. 14. Debarking was easy in the species of A. koreana and M. thunbergii, and debarking after being boiled in water was the most efficient in all species.

  • PDF