• Title/Summary/Keyword: equivalent frequency

Search Result 1,508, Processing Time 0.027 seconds

Z-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 Z영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Kim, K.Y.;Lee, J.T.;Han, H.H.;An, B.C.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.145-146
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using Z-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Changes in the Orientation and Frequency Dependence of Target Strength due to Morphological Differences in the Fish Swim Bladder (어류 부레의 형태학적 차이에 따른 음향산란강도의 자세 및 주파수 의존성의 변화)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.2
    • /
    • pp.233-243
    • /
    • 2015
  • Controlled broadband acoustic scattering laboratory experiments were conducted using a linear chirp signal (95-220 kHz), and x-ray images of live and model fish with an artificial swim bladder were analyzed to investigate the changes in orientation and frequency dependence of target strength (TS) due to morphological differences in fish swim bladders. The broadband echoes from live and model fish were measured over an orientation angle range of ${\pm}45^{\circ}$ in the dorsal plane and in approximately $1^{\circ}$ increments. The location of nulls in the simulated echo response of the SINC [sinc function] model was overlaid on the TS map, showing the orientation and frequency dependence of fish TS, and they matched very well. It was possible to infer the equivalent fish scattering size (or swim bladder) using the null spacing in the experimentally obtained broadband TS map. Good agreement was observed for inferring the equivalent scattering size between the SINC model and the broadband echoes measured for the three fish species (black scraper Thamnaconus modestus; goldeye rockfish Sebastes thompsoni; and whitesaddled reef fish Chromis notatus). Some results of this inference are discussed.

Approximate Equivalent-Circuit Modeling and Analysis of Type-II Resonant Immittance Converters

  • Borage, Mangesh;Nagesh, K.V.;Bhatia, M.S.;Tiwari, Sunil
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.317-325
    • /
    • 2012
  • Resonant immittance converter (RIC) topologies can transform a current source into a voltage source (Type-I RICs) and vice versa (Type-II RICs), thereby making them suitable for many power electronics applications. RICs are operated at a fixed frequency where the resonant immittance network (RIN) exhibits immittance conversion characteristics. It is observed that the low-frequency response of Type-II RINs is relatively flat and that the state variables associated with Type-II RINs affect the response only at the high frequencies in the vicinity of the switching frequency. The overall response of a Type-II RIC is thus dominated by the filter response, which is particularly important for the controller design. Therefore, an approximate equivalent circuit model and a small-signal model of Type-II RICs are proposed in this paper, neglecting the high-frequency response of Type-II RINs. While the proposed models greatly simplify and speed-up the analysis, it adequately predicts the open-loop transient and small-signal ac behavior of Type-II RICs. The validity of the proposed models is confirmed by comparisons of their results with those obtained from a cycle-by-cycle simulation and with an experimental prototype.

Eigenvalue Analysis of Symmetrically Stepped Beams by Equivalent Beam Transformation (대칭단헝 단순보의 등가보 변환에 의한 고유치 해석)

  • Jung Jae-Chul;Moon Sang-Pil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.55-62
    • /
    • 2006
  • The natural frequency of a beam plays a critical role in the dynamic analysis of beams. Especially it is a complicated and difficult task to analyse the natural frequency of a stepped beam with an irregularly varying section. The lumped mass methods, multi-degree of freedom analyses, are mainly used for the analysis of this kind of stepped beams. The accuracy of these methods are determined by the number of the partitions of elements, the number of the iterations in calculation, and the accuracy of assumed mode shapes. This study presents a method of transformation from symmetrically stepped beams to an equivalent beam and a method of the eigenvalue analysis. Appropriateness and utility of this method are demonstrated by comparing examples from other literatures and various models.

CALCULATION OF INDUCTANCES OF TRANSFORMER EQUIVALENT NETWORK FOR HIGH FREQUENCY INTERFERENCE CONDUCTION ANALYSIS

  • Chen, Dongjun;Hao, Rongtai
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.592-594
    • /
    • 1998
  • In order to analysis high frequency interference conduction in transformer, this paper constructs a equivalent network based on P.I. Fergested transformers physical model. A method of calculating self and mutual leakage inductance of windings sections is presented and a calculating example is given.

  • PDF

A Studyon the Equivalent Model Transformation of the Discrete Linear Systems (이산 선형 시스템의 등가 모델 변환에 관한 연구)

  • 임승우;김정화;정찬수
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1991.10a
    • /
    • pp.215-219
    • /
    • 1991
  • This paper is equivalent model transform which reduces the restriction of digitalization in the discrete linear system. This algorithm is the method that weight is given to contribillity and obserbility gramian, the regular matrix T of coordinate transform is obtained and then the state space coefficents of weighted model can be obtained. This study shows the frequency reponse of low quantization error according to the order of weighting function. The result shows that frequency response of the proposed algorithm is better than that of the balanced realization in the system of smaller bit.

Equivalent System for Electromagnetic Transients Study (전자기 과도 현상 해석을 위한 등가 시스템)

  • Park, Jong-Keun;Hong, Jun-Hee;Park, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.843-847
    • /
    • 1988
  • In electromagnetic transient analysis studies, complex transmission system should be modelled in detail. But in large system, modelling of complete system is a big burden in many sides such as computation time, modelling efforts. It is needed to model only a concerned part of the system in detail. The remaining parts of the system have to be reduced to equivalents. This study suggests a method of generating a simple network equivalents which has equivalent frequency charastics in wide frequency range.

  • PDF

Effect of Loading Frequency Dependent Soil Behavior on Seismic Site Effect (하중의 주파수에 의하여 지배받은 흙의 동적 거동이 부지증폭현상에 미치는 영향)

  • Park Du-Hee;Hashash Y.M.A;Lee Hyun-Woo;Kim Jae-Yoen
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.3
    • /
    • pp.23-35
    • /
    • 2006
  • Equivalent linear analysis is widely used in estimating local seismic site effects. The soil behavior in the analysis is often assumed to be rate-independent and is not influenced by the seismic loading frequency. Laboratory results, however, indicate that cohesive soil behavior is greatly influenced by the loading frequency. A new equivalent linear analysis method that accounts for the loading frequency dependent soil behavior is developed and used to perform a series of one dimensional site response analyses. Results indicate that while frequency dependent shear modulus has limited influence on computed site response, frequency dependent soil damping greatly filters out high frequency components of the ground motion and thus results in lower response.

Beat Control Using an Equivalent Ring Model (등가 종 모델을 이용한 맥놀이 조절법)

  • Kim, Seockhyun;Lee, Joonghyeok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.516-519
    • /
    • 2012
  • This study proposes a method of an equivalent bell model in order to tune the beat period of a Korean bell. In a Korean bell having a slight asymmetry, each circumferential mode splits into a mode pair which has a slight difference in frequency, and the interaction of the mode pair makes a beat in vibration and sound. An equivalent bell model which consists of an axi-symmetric bell and an equivalent point mass, has the same mode property as in a real bell. The equivalent bell model is constructed by the finite element analysis based upon the theory of a revolutionary shell Using the equivalent bell model, the beat period is predicted when the bell thickness is locally decreased to improve the beat property. The predicted result is verified by experiment on a test bell. The proposed method is useful to save the time required for tuning the beat period of a large bell.

  • PDF

A Study on Resonance Tracking Method of Ultrasonic Welding Machine Inverter (초음파 용접기 인버터의 공진 추종 방법에 관한 연구)

  • Moon, Jeong-Hoon;Park, Sung-Jun;Lim, Sang-Kil;Kim, Dong-Ok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.481-490
    • /
    • 2021
  • In the ultrasonic welding machine, when the load fluctuates, the L and C of the piezo element in the oscillation part change. As a result, the resonant frequency is changed, so it is necessary to match the operating frequency of the ultrasonic welding machine to the new resonant frequency. That is, in order to maximize the output of the oscillation unit of the ultrasonic welding machine, it is inevitable to follow the resonance frequency. Accordingly, many methods for following the resonant frequency are being actively studied. In addition, in order to check the effect of external inductance on the operation of the ultrasonic welding machine, The equivalent circuit of the piezo element was analyzed by including the external inductance for resonance in the equivalent circuit of the piezo element, and the method of selecting an appropriate inductance was described. In this paper, we propose a new system that allows the switching frequency of the inverter to tracking the resonance frequency even if the resonance frequency is changed due to the load of the ultrasonic welding machine.