• Title/Summary/Keyword: equivalent diameter

Search Result 308, Processing Time 0.026 seconds

Performance Measurement of Siemens Inveon PET Scanner for Small Animal Imaging (소동물 영상을 위한 Siemens Inveon PET 스캐너의 성능평가)

  • Yu, A-Ram;Kim, Jin-Su;Kim, Kyeong-Min;Lee, Young-Sub;Kim, Jong-Guk;Woo, Sang-Keun;Park, Ji-Ae;Kim, Hee-Joung;Cheon, Gi-Jeong
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Inveon PET is a recently developed preclinical PET system for small animal. This study was conducted to measure the performance of Inveon PET as recommended by the NEMA NU 4-2008. We measured the spatial resolution, the sensitivity, the scatter fraction and the NECR using a F-18 source. A 3.432 ns coincidence window was used. A $1\;mm^3$ sized F-18 point source was used for the measurement of spatial resolution within an energy window of 350~625 keV. PET acquisition was performed to obtain the spatial resolution from the center to the 5 cm offset toward the edge of the transverse FOV. Sensitivity, scatter fraction, and NECR were measured within an energy window of 350~750 keV. For measuring the sensitivity, a F-18 line source (length: 12.7 cm) was used with concentric 5 aluminum tubes. For the acquisition of the scatter fraction and the NECR, two NEMA scatter phantoms (rat: 50 mm in diameter, 150 mm in length; mouse: 25 mm in diameter, 70 mm in length) were used and the data for 14 half-lives (25.6 hr) was obtained using the F-18 line source (rat: 316 MBq, mouse: 206 MBq). The spatial resolution of the F-18 point source was 1.53, 1.50 and 2.33 mm in the radial, tangential and axial directions, respectively. The volumetric resolution was $5.43\;mm^3$ in the center. The absolute sensitivity was 6.61%. The peak NECR was 486 kcps @121 MBq (rat phantom), and 1056 kcps @128 MBq (mouse phantom). The values of the scatter fraction were 20.59% and 7.93% in the rat and mouse phantoms, respectively. The performances of the Inveon animal PET scanner were measured in this study. This scanner will be useful for animal imaging.

Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery (방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구)

  • Kim, Mi-Sook;Ha, Seong-Hwan;Lee, Dong-Han;Ji, Young-Hoon;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Park, Chan-Il;Kim, Il-Han;Ye, Seong-Jun;Park, Jae-Hong;Kim, Kum-Bae
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.268-277
    • /
    • 2007
  • Purpose: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. Materials and Methods: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. Results: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the $30{\sim}50$ mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. Conclusion: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Preferential Flow as Tested by Breakthrough Curves of Cl- and Cu2+ from Saturated Undisturbed Soil Core Samples under Steady Flow Conditions (포화 불교란 토양시료의 Cl- 및 Cu2+ 출현곡선에 의한 preferential flow의 검증)

  • Yoo, Sun-Ho;Han, Kyung-Hwa;Ro, Hee-Myong;Han, Gwang-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.2
    • /
    • pp.71-78
    • /
    • 2000
  • Preferential flow has recently been the subject of increasing interest because these phenomena contribute to solute transport in soils. Commonly, preferential flow paths are associated with macropores or highly structured soils. We presented an analysis of the measured breakthrough curves (BTCs) of $Cl^-$ and $Cu^{2+}$ ions to test the occurrence of preferential flow in soils using miscible displacement technique under steady flow conditions. We also analyzed soil water retention curves and from this curves induced cumulative pore size distribution of undisturbed soils, which sampled from Ap1, B1, and C horizons of Songjeong series soils (the fine loamy, mesic family of Typic Hapludults). In this study, miscible displacement experiment on C horizon was excluded, because it is structureless sandy loam with saturated hydraulic conductivity of $5.2cmhr^{-1}$. The saturated hydraulic conductivity of Ap1 horizon was $2.0cmhr^{-1}$, which was about 7 times higher than that of B1 horizon ($0.27cm hr^{-1}$). Cumulative pore size distribution predicted that Ap1 horizon had more macropores (pore diameter larger than $49{\mu}m$, equivalent to -6 kpa of soil matric potential) than B1 horizon. The hydrodynamic dispersion coefficient from chloride BTCs was estimated as $1.3cm^2hr^{-1}$ for B1 and $34cm^2hr^{-1}$ for Ap1 horizon. However the retardation factors of B1 and Ap1 horizon were significantly different, i.e. 1 and 0.6, respectively, which means that there was distinct partition between mobile water and immobile phase in Ap1 horizon. The copper retardation effect of Ap1 horizon was less than that of B1 horizon, even though cation exchange capacity of Ap1 horizon was higher than that of B1 horizon. Thus, breakthrough curves of $Cl^-$ and $Cu^{2+}$ obviously showed the probability that preferential flow would occur in Ap1 horizon.

  • PDF

Determination of the Optimum Application Rate of Pig Slurry for Red Pepper Cultivation (고추에 대한 돈분액비 시용기준 설정)

  • Kang, Bo-Goo;Kim, Hyun-Ju;Lee, Gyeong-Ja;Park, Seong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.6
    • /
    • pp.388-395
    • /
    • 2004
  • This study was carried out to determine the application rate of pig slurry for red pepper. Field experiment was designed with non-fertilizer, chemical fertilizer recommended by soil testing (CFRST) and pig slurry treatments. In pig slurry (PS) plots, pig slurry was applied as basal fertilizer with different equivalents to nitrogen of chemical fertilizer plot (60%: PS60, 80%: PS80, 100%: PS100, 120%: PS120) and chemical fertilizer was top-dressed additionally. Soil organic matter contents after 50 day of planting and after experiment in the plots treated with PS were higher than that of CFRST plot, whereas content of $NO_3-N$ of CFRST plot was higher than that of PS plot. Growth of red pepper were lowest in the non-fertilizer plot. Plant lengths of red pepper at 50 day after planting were similar among the different treatments, plant lengths of red pepper of PS100, PS120 and CFRST at 100 day after planting were higher than those of the PS60 and PS80 plots. But Main stem and stem diameter of red pepper were not different among the treatments. Uptake rate of N, P and K by red pepper plant were 27-44, 9-16 and 41-68% for total N, $P_2O_5$ and $K_2O$, respectively. Utilization of applied fertilizer ingredient by red pepper plant were in the order of PS80> PS60> FRST> PS100> PS120. Yield of red pepper tends to increase by 3% in the PS100 compared with the CFRST, but there was not significant difference between PS120 and CFRST. Chemical component of run-off collected from the furrow of the red pepper field was not different among the treatments. Greenhouse gases ($CH_4$ and $N_2O$) emission of non-fertilizer, PS100 and CFRST during the whole red pepper growth period were 4.0, 4.8 and $5.9kg\;CH_4\;ha^{-1}$, and 0.74, 6.68 and $8.38kg\;N_2O\;ha^{-1}$. Emission of $CH_4$ and $N_2O$ in PS100 was higher than those of CFRST by 23% and 26%, respectively. In this connection, to be used the pig slurry for red pepper, it is required that pig slurry must be decomposed for six months or more. Consequently, pig slurry equivalent to nitrogen of basal fertilizer of CFRST with additional top dressing of chemical fertilizer is recommend as an optimum application rate of pig slurry for red pepper.

Anatomical Studies on Tumorous Tissue Formed in a Stem of Ailanthus altissima Swingle by Artificial Banding and Its Subsequent Removing Treatment -Characters of Individual Elements- (인위적(人爲的)인 밴드결체(結締) 및 해체처리(解締處理)로 형성(形成)된 가죽나무(Ailanthus altissima Swingle) 수간(樹幹)의 종양조직(腫瘍組織)에 관한 해부학적(解剖學的) 연구(硏究) -조직(組織) 구성세포(構成細胞)의 특성(特性)-)

  • Eom, Young Geun;Lee, Phil Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.3
    • /
    • pp.287-301
    • /
    • 1989
  • A tree of Ailanthus altissima Swingle was fastened with a plastic band, 19mm wide, around the stem 180cm above ground level and was left to grow under this condition for one year, By removal of this band the tumorous tissue gradually developed and the tree bearing distinct tumorous tissue, an overgrowth surrounding the stem, was harvested two years after the band removal. For the investigation of this tumorous part and its comparison with adjacent normal parts in the anatomical features of individual elements, the tumorous part and parts directly and 40cm above and below the tumorous part were obtained from the tree. The tumor wood having remarkably wider growth increment occurred in the 3rd growth ring the first year after removal of the fastened band, and the barrier zone which delimited the discolored wood from the normal-colored wood inwards appeared u1 the intra-2nd growth ring produced during the fastened period in the tumorous part and the false ring-like zones equivalent to barrier Zone were shown in the normal-colored 2nd growth rings of the parts directly and 40cm above and below the tumorous part, as well. The tumor wood, the 3rd growth ring, and proportion of the 2nd growth ring formed after barrier zone in the tumorous part shared common characteristics in the irregular growth ring boundary, misshapen and shorter individual fibers and vessel elements, and large ray widths and heights. The springwood pores were smaller in diameter in the tumor wood, and the larger radial and smaller tangential diameters of summerwood solitary pores and individual pores consisting of pore multiples in proportion of the 2nd growth ring formed after the barrier zone were transformed into near-isodiametric in the tumor wood, the 3rd growth ring, in the tumorous part. Only in proportion of the 2nd growth ring formed after the barrier zone were transformed into near-isodiametric in the tumor wood, the 3rd growth ring, in the tumorous part, ray densities greatly increased. And the massive tumor wood was caused not by cell size but by cell number because the radial and tangential diameters of fibers in the tumor wood, the 3rd growth ring, in the tumorous part were not sufficiently different from those in the same aged growth rings of the directly and 40cm above and below the tumorous part.

  • PDF