• Title/Summary/Keyword: equipments

Search Result 4,485, Processing Time 0.031 seconds

A Survey on Utilization of Health Center and Health Service Demand of Residents in a Urban and Rural Unified Community (일개 도시·농촌 통합지역 주민의 보건기관 이용경험과 보건서비스 요구도 조사)

  • Lim, Bu-Doll;Lee, Ju-Young
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.1
    • /
    • pp.99-112
    • /
    • 2000
  • This survey was conducted to assess the utilization of health center including health sub-center and community health post and the health service demand of residents in a urban and rural unified community. Officials in Up·Myun·Dong offices visited randomly sampled 4,027 households(4.6% of total households in unified City) which included 3,337 households in urban area(4.9% of total households) and 690 households in rural area(3.7% of total households) and interviewed with heads or housewives of the households in September, 1995. There were significant differences in health-related demographic characteristics including age-sex distribution, educational level, period of residence in the community and medical insurance status of the interviewees between urban and rural areas. Of the respondents, 64.8% in urban area and 55.6% in rural replied that they had utilized the health center in the past. The most common purpose for visiting the health center was to get vaccination in urban area and to get outpatient care in rural area. The top priority health center activity that needs to be reinforced was communicable disease control and over 90% of the respondents preferred to have mobile clinic and home health care service in were also highly demanded. Eighty-six percent of the urban respondents replied that a health sub-center must be established in urban area. In the rural area, 90.3% of the respondents replied that they wanted to maintain the health sub-center and 88.3% wanted to maintain the community health post. Along with the improvement of facilities and equipments of the health center by Rural Health Service Improvement Project, new health service programs must be developed to meet the demand of the community.

  • PDF

A Prediction Model for the Radiation Safety Management Behavior of Medical Cyclotrons (의료용 Cyclotron의 방사선안전관리 행위 예측모형)

  • Jung, Ji-Hye;Han, Eun-Ok;Kim, Ssang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.77-86
    • /
    • 2008
  • This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: Step 1 is a production preparation step, Step 2 is an RI production step, Step 3 is a synthesis step, Step 4 is a distribution step, Step 5 is a quality control step, Step 6 is a carriage container packing step, and Step 7 is a transportation step. it was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipments' were the most difficult as 9 subjects (37.5%), and In the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was $3.46{\pm}0.47$ out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in radiation safety managements, general characteristics, organization characteristics, and selfefficacy didn't show a significant path statistically in which the prosperity and well-being programs in job characteristics affected the behavior in radiation safety managements. Therefore, it is necessary to establish a strategy that improves the level of prosperity and well-being levels in job characteristics in order to increase the behavior in radiation safety managements. Thus, this study provides basic materials for the radiation safety management of Cyclotron through the full-scale investigation that is first applied in Korea.

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

Teachers' Importance Perception of the Contents in Housing Unit of Middle School Technology and Home Economics Subject (중학교 기술 가정 교과의 주생활단원 내용에 대한 교사의 중요도 인식)

  • Jun, Kyung-Sook
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.4
    • /
    • pp.223-237
    • /
    • 2008
  • The purpose of this research was to provide the information needed for improving the contents in housing unit of middle school technology and home economic textbook. For this purpose, a survey questionnaire was developed to examine teachers' importance perception of 48 contents in housing unit. A direct survey and an e-mail survey were used to collect data from teachers, and a total number of 233 data were analyzed. Conclusions were summarized as following: 1. Among the 48 contents in housing unit, the average score of teachers' importance perception of the 18 contents on 'interior environment and equipments' was 3.94; the average score of teachers' importance perception of the 15 contents on 'living space plan and use' was 3.78; and the average score of teachers'importance perception of the 15 content on 'housing maintenance and repair' was 3.42. Therefore, the 15 contents on 'housing maintenance and repair' must be revised. 2. Teachers' importance perception of 25 contents, among the 48 contents in housing unit, were significantly differentiated by gender, age, teaching experience, scholastic attainment, subject in charge(technology, home economics, technology and home economics), school type(boys' middle school, girls' middle school, coeducation), and region(city, county). Therefore, the 25 contents, of which importance perception were influenced by teachers' characteristics, must be revised in order to maintain the consistent importance perception. Suggestions were that the team teaching of technology and home economic textbook was more recommendable; that the local situations must be considered in the contents of housing unit and; that the contents of housing unit must be segmented into a minimum unit for the accurate evaluation.

  • PDF

A Study on the Geophysical Characteristics and Geological Structure of the Northeastern Part of the Ulleung Basin in the East Sea (동해 울릉분지 북동부지역의 지구물리학적 특성 및 지구조 연구)

  • Kim, Chang-Hwan;Park, Chan-Hong
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.625-636
    • /
    • 2010
  • The geophysical characteristics and geological structure of the northeastern part of the Ulleung Basin were investigated from interpretation of geophysical data including gravity, magnetic, bathymetry data, and seismic data. Relative correction was applied to reduce errors between sets of gravity and magnetic data, obtained at different times and by different equipments. The northeastern margin of the Ulleung Basin is characterized by complicated morphology consisting of volcanic islands (Ulleungdo and Dokdo), the Dokdo seamounts, and a deep pathway (Korea Gap) with the maximum depth of -2500 m. Free-air anomalies generally reflect the topography effect. There are high anomalies over the volcanic islands and the Dokdo seamounts. Except local anomalous zones of volcanic edifices, the gradual increasing of the Bouguer anomalies from the Oki Bank toward the Ulleung Basin and the Korea Gap is related to higher mantle level and denser crust in the central of the Ulleung Basin. Complicated magnetic anomalies in the study area occur over volcanic islands and seamounts. The power spectrum analysis of the Bouguer anomalies indicates that the depth to the averaged Moho discontinuity is -16.1 km. The inversion of the Bouguer anomaly shows that the Moho depth under the Korea Gap is about -16~17 km and the Moho depths towards the Oki Bank and the northwestern part of Ulleung Island are gradually deeper. The inversion result suggests that the crust of the Ulleung Basin is thicker than normal oceanic crusts. The result of 20 gravity modeling is in good agreement with the results of the power spectrum analysis and the inversion of the Bouguer anomaly. Except the volcanic edifices, the main pattern of magnetization distribution shows lineation in NE-SW. The inversion results, the 2D gravity modeling, and the magnetization distribution support possible NE-SW spreading of the Ulleung Basin proposed by other papers.

Ground Security Activities for Prevention of Aviation Terrorism -Centered on San Francisco International Airport of the U.S.A.- (항공테러방지를 위한 지상 보안활동 -미국 샌프란시스코국제공항을 중심으로-)

  • Kang, Maeng-Jin;Kang, Jae-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.195-204
    • /
    • 2008
  • With the growth of airline management, as well as computer and IT security, the international trade in this modern society has been rapidly increasing, Along with the advancing, airplanes have become a universal means of communication. However, the complications associated with airplane safety have also been brought up as a result, the most concerning of which is terrorism. One of the main counterplans for preventing terrorism is Ground security activities the core of Ground security activities is absolute safety for passengers in both passenger terminal and freight terminal. Subastral security refers to physical protection, proximity control and 100% security search and freight guarding of the passengers' possessions, and the personnel's duties to perform such jobs are be! coming more crucial. On the other hand, Airport security check has bee n gradually developing since the 1960's, when hijacking began to take place. Although the airports have been providing more safe and comfortable services to their customers, terrorism is still happening today. When Ground security activities is minute, the users feel displeasure and discomfort, yet considering solely their convenience can brings problems in achieving safety. Since the 9.11 terror in 2001, the idea of improving and strengthening airport security was reinforced and a considerable amount of estate is being spent today for invention and application of new technology. Various nations, including the United States, have been improving their systems of security through public services; public police department is actively carrying out their duties in airports as well. In San Francisco International Airport, private police department is in charge of collection of data, national events, VIP protection, law enforcement, cooperation within facilities, daily-based patrol and traffic control. Under guidance and supervision of national organizations, such as TSA, general police department interprets X-Rays, operates metal detectors, checks passports or IDs and observes reactions to explosives. Under these circumstances, studies about advancement of cooperation and duties of general police department and private police department necessitated: especially about private police department and their training for searching equipments, decrease in number of turn over rate, invention of technology and prior settlement in estate for security. The privacy of the public, who make up the major population of airport passengers, must also be minimized. In the following research, the activities of police departments in San Francisco International Airport will be analyzed in order to understand recent actions of the United States on airport security.

The Construction of QoS Integration Platform for Real-time Negotiation and Adaptation Stream Service in Distributed Object Computing Environments (분산 객체 컴퓨팅 환경에서 실시간 협약 및 적응 스트림 서비스를 위한 QoS 통합 플랫폼의 구축)

  • Jun, Byung-Taek;Kim, Myung-Hee;Joo, Su-Chong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.11S
    • /
    • pp.3651-3667
    • /
    • 2000
  • Recently, in the distributed multimedia environments based on internet, as radical growing technologies, the most of researchers focus on both streaming technology and distributed object thchnology, Specially, the studies which are tried to integrate the streaming services on the distributed object technology have been progressing. These technologies are applied to various stream service mamgements and protocols. However, the stream service management mexlels which are being proposed by the existing researches are insufficient for suporting the QoS of stream services. Besides, the existing models have the problems that cannot support the extensibility and the reusability, when the QoS-reiatedfunctions are being developed as a sub-module which is suited on the specific-purpose application services. For solving these problems, in this paper. we suggested a QoS Integrated platform which can extend and reuse using the distributed object technologies, and guarantee the QoS of the stream services. A structure of platform we suggested consists of three components such as User Control Module(UCM), QoS Management Module(QoSM) and Stream Object. Stream Object has Send/Receive operations for transmitting the RTP packets over TCP/IP. User Control ModuleI(UCM) controls Stream Objects via the COREA service objects. QoS Management Modulel(QoSM) has the functions which maintain the QoS of stream service between the UCMs in client and server. As QoS control methexlologies, procedures of resource monitoring, negotiation, and resource adaptation are executed via the interactions among these comiXments mentioned above. For constmcting this QoS integrated platform, we first implemented the modules mentioned above independently, and then, used IDL for defining interfaces among these mexlules so that can support platform independence, interoperability and portability base on COREA. This platform is constructed using OrbixWeb 3.1c following CORBA specification on Solaris 2.5/2.7, Java language, Java, Java Media Framework API 2.0, Mini-SQL1.0.16 and multimedia equipments. As results for verifying this platform functionally, we showed executing results of each module we mentioned above, and a numerical data obtained from QoS control procedures on client and server's GUI, while stream service is executing on our platform.

  • PDF

Effectiveness Analysis for Traffic and Pedestrian Volumes of Pedestrian Pushbutton Signal (차량 및 보행자 교통량에 따른 보행자 작동신호기의 효과 분석)

  • Cho, Han-Seon;Park, Ji-Hyung;Noh, Jung-Hyun
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.33-43
    • /
    • 2007
  • Because usually signal controllers on the crosswalks of mid-block provide pedestrian signals every cycle based on the fixed signal plan, pedestrian signals are provided even when there is no pedestrian demand. Consequently, signal is operated inefficiently and this may cause drivels to experience useless delay or violate the signal. Even though recently pushbuttons have been installed to improve the efficiency of pedestrian signal control in the crosswalks of mid-block and the pedestrian safety. they are not spread out national-wide in Korea because of the cost of the pushbutton equipments and the lack of an acknowledgement of the efficiency of the pushbutton. In this study, the effectiveness of the pushbutton on saving the vehicle delay was verified through before and after study in 4 study sites using a traffic micro-simulation model, VISSIM. To evaluate the viability of the pushbutton, a benefit/cost analysis was also performed for 4 study sites. It was found that B/C ratio of all of 4 study sites was greater than 1. The sensitivity analysis for the traffic volume and pedestrian volume were performed to identify the impact of the both volume on the operation of pushbutton. And, a benefit/cost analysis was performed for all scenarios. It was found that when the pedestrian volume is greater than 90ped/h, the pedestrian signal was operated same as the fixed signal plan. That is, there is no benefit of pushbutton at all once the pedestrian volume is greater than 90ped/h. When the pedestrian volume is equal to or less than 90ped/h and the traffic volume is greater than 2,500veh/h, B/C ratio is greater than 1. Also it was found that as traffic volume increases and pedestrian volume decreases, the benefit increases. In this study, the criteria for installation of pushbutton on the crosswalks of mid-block are developed through the sensitivity analysis and benefit/cost analysis. The results of this study may be used as a criteria for expansion of pushbutton system.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF