• Title/Summary/Keyword: equipment replacement

Search Result 194, Processing Time 0.032 seconds

Effects of Resistance Exercise with Pressure Biofeedback Unit on the Gait Ability and Knee Joint Function in Subject with Total Knee Replacement Patients

  • Jin Park
    • The Journal of Korean Physical Therapy
    • /
    • 제36권1호
    • /
    • pp.27-32
    • /
    • 2024
  • Purpose: This study was conducted to verify the effect of applying a pressure biofeedback unit on walking ability and knee joint function while performing knee joint extensor strengthening exercises using resistance exercise equipment in total knee replacement (TKR) patients. Methods: This study was conducted on twelve patients receiving rehabilitation treatment after being admitted to a rehabilitation hospital post-TKR. Of these, six were allocated to a feedback group with a pressure biofeedback unit, and the other 6 were allocated to a control group without a pressure biofeedback unit. The subjects performed an exercise program for 45 minutes per session, five times a week, for two weeks. Walking ability and knee joint function were evaluated and analyzed before and after exercise. Results: The feedback group showed significantly better improvements in walking speed, gait cycle, step length on the non-operation side, time on the foot on the operation side, K-WOMAC stiffness, and K-WOMAC function than the control group (p<0.05). Conclusion: When strengthening the knee joint extensor muscles using resistance exercise equipment in TKR patients, the provision of a pressure biofeedback unit was found to improve walking ability and knee joint function by inducing concentric-eccentric contraction of the knee joint extensor muscles. Therefore, the study shows that exercise based on the provision of a pressure biofeedback unit should be considered when strengthening knee joint extensor muscles to improve the walking ability and knee joint function of TKR patients in clinical practice.

Methods to Reduce Greenhouse Gas for University Buildings to Make a Low-Carbon Green Campus - With Case Study on the 'E' University -

  • Song, Su Min;Peom, Sung Woo;Park, Hyo Soon;Song, Kyoo Dong
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.37-46
    • /
    • 2014
  • University buildings are energy-guzzling facility that consume more than 10,000TOE within a campus annually. Even the consumption is on an upswing trend. Behind such high consumption are there cheap power rates for education facility, lack of high-efficiency equipment and ever-increasing use of various information equipment. Being keenly aware that greenhouse gas emission increases due to such rise of energy consumption, the present study carried out a case study. In the case study, the study chose the buildings of E university from top 10 universities that consume energy most in Seoul and examined the current status of their energy consumption and greenhouse gas emission. And then it set the reduction target of greenhouse gas by year. Putting aside a middle and long-termed strategy for later endeavor, it first established the 1st year's implementation plan (2014) for energy saving and greenhouse gas reduction with limited budget and according to greenhouse gas reduction target. The plan is specified as follows. Targets for energy saving are mainly divided into two sectors: machine equipment and electric equipment. 7 ideas were proposed. Three ideas to improve machine equipment are to replace with high-efficiency boilers and chillers and to adjust the position of the cooling tower. By doing so, it was estimated that energy could be saved by 176.34TOE in total and greenhouse gas could be reduced by 370.771t$CO_2$-eq. Four ideas to improve electric equipment include the replacement with LED lights, LED emergency lights and high-efficiency motors and the installation of motion sensors. It was calculated that such replacement could conserve 1,076.08TOE (electric energy) and reduce 2,181.420t$CO_2$-eq (greenhouse gas).

Effect of crumb rubber on compressive behaviour of CRCFST stub columns

  • Liu, Dawei;Liang, Jiongfeng;Zhang, Guangwu;Wang, Jianbao
    • Computers and Concrete
    • /
    • 제25권3호
    • /
    • pp.267-272
    • /
    • 2020
  • This paper investigates the effect of crumb rubber (CR) on compressive behaviour of crumb rubber concrete filled steel tube (CRCFST) stub columns. Therefore, experiments on 16 stub columns subjected to axial loading are carried out. The results show that the failure modes of CRCFST stub columns with different CR replacement ratios and CR size are similar, manifested the buckling of the outer steel tube. The axial bearing capacity and stiffness both decrease with an increase in CR replacement ratio, and with decreasing CR size.

대형 조선소의 블록 물류 시뮬레이션 (Simulation of Block Logistics at a Big Shipyard)

  • 송창섭;강용우
    • 한국CDE학회논문집
    • /
    • 제14권6호
    • /
    • pp.374-381
    • /
    • 2009
  • To meet the soaring demand recently, South Korea big shipbuilders are examining two things. One is new investment in plant and equipment. The other is replacement of production resources. Considering plant & equipment investment and replacement of production resources, even if actual production ability would be enough, the real output could be affected by limitation of logistics with lack of analysis. As we set up big shipyard in virtual space, we could perform actual production by using confirm production plan in virtual space. We've analyzed the load of block stock, load of road and load of transporter for logistics effects are followed by production increase. This research is to determine the possible problems of those analyzed results and to present the resolution using the current layout. And then modified yard layout, we reanalyzed previous three logistics effects. This simulation model could help administrator to make rational decision for changing yard layout.

캘리포니아 표준테스트 방법을 사용한 전기냉방기기의 가스냉방기기 대체에 따른 편익비용분석 (Benefit-Cost Analysis in Accordance with Replacement of Electrical Cooling System by Gas Cooling System using the California Standard Test)

  • 박래준;송경빈;원종률
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1774-1781
    • /
    • 2012
  • There are some efforts to improve the performance of electrical heat pump(EHP) and replace it with an alternative cooling equipment such as gas engine-driven heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. This paper analyzes cost-benefit in accordance with replacement of electrical cooling system by gas cooling system using california standard test and sensitivity analysis of some scenarios.

LCC 분석을 통한 공조설비 내구연한 산정 (An Estimation of the Economic Life Expectancy of the Building Service Equipment with LCC Analysis)

  • 강성주;김용기;이태원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.316-321
    • /
    • 2007
  • It is difficult for a superintendent or an operator of building service systems and equipment to decide the reasonable time for management of himself due to the shortage of his specialty for repair or replacement of a part of or whole equipment. But The reliable life expectancies for various building service equipment have not been prepared yet. This study shows the difference of optimal economic life and the decrease of running cost and energy consumption according to management level of the building equipment by the LCC analysis. The numerical model for building HVAC system was composed and analyses were performed for several parameters with management.

  • PDF

The Aging of Signalling Equipment and the Impact on Maintenance Strategies

  • Antoni, Marc
    • International Journal of Railway
    • /
    • 제2권3호
    • /
    • pp.107-112
    • /
    • 2009
  • Research projects of SNCF aim at reducing the costs of infrastructure possessions and improving the operational equipment availability and safety. This permanent search for a better regularity led the SNCF to analyse the maintenance approach of signalling equipment in detail. Until now, it was commonly acknowledged that signalling equipment, which consists of many electronic devices, is not subject to aging. In this study, a Weibull lifetime model, able to describe an aging phenomenon, is used and it can be shown that the deterioration is statistically significant. The validity of the model is tested. We also analyse the influence of environmental covariates. We simulate different scenarios in order to investigate the impact of several maintenance strategies as well as on future maintenance costs, on the amount of components to replace based on the mean age of the network. It can be shown that in most cases a systematic replacement strategy offers the best solution.

  • PDF

누적(累積), 손상(損傷), 모형(模型)의 특이(特異)한 경우(境遇)에 관(關)한 연구(硏究) (On a Special Case of a Problem in the Cumulative Damage Model)

  • 이효성
    • 대한산업공학회지
    • /
    • 제7권1호
    • /
    • pp.33-36
    • /
    • 1981
  • An equipment is subject to shocks which occur randomly according to a Poisson process. The equipment fails when the total cumulative damage reaches a certain prescribed level. An optimal preventive replacement policy is presented when the level of cumulative damage cannot be checked. Renewal theory is used to obtain the results and a case example is presented.

  • PDF

고압수용가 수전설비 교체주기에 관한 연구 (Study on power equipment maintenance and replacement cycle)

  • 이일무;유상봉;정해성;노선환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1460-1460
    • /
    • 2015
  • Power equipment, since different life according to use environment, there is a need for systematic maintenance management Efforts to reduce the economic losses due to accidents by making self evaluation table will be necessary.

  • PDF

전기화재에 따른 진공차단기의 건전성 평가 (A Study on the Evaluation of Reliability of the Vacuum Circuit Breaker for the Electrical Fire)

  • 최홍규;박준열
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.24-28
    • /
    • 2013
  • Fire-hited electrical equipment has possibility of deterioration. So its replacement is essential in terms of safety. However, the economic burden is increased. Therefore, the replacement or re-use of it is to be determined by tests. But the research of Integrity Assessment on Fire-hited electrical equipments is very rare. In this paper, we tested to determine the replacement or re-use of Fire-hited vacuum circuit breaker. And provided the data for the integrity assessment through the analysis of its deterioration.