• Title/Summary/Keyword: equipment interface

Search Result 536, Processing Time 0.03 seconds

The On-Board Test Study of Train Diagnostic and Control System Using TCN(IEC 61375-1) (TCN(IEC 61375-1)을 이용한 열차진단제어장치의 실증시험 연구)

  • Kim, Hun;Hong, Goo-Sun;Han, Jeong-Soo;Choi, Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1413-1427
    • /
    • 2007
  • The Train Networks has a goal which requires the fast and correct data communication for distributable equipment systems. For this, in 1999, some train makers had established the standard TCN(IEC61375-1) for the inter-operating between equipment systems. Recently, TCN is being used in EU, China and the requirement to use it is growing up by many other countries more and more. The TCN was adopted at Korea High-speed Train with first in Korea, and Rotem Company finished the design of TCMS with TCN network for Istanbul EMU and KTX-2 Train and tests them. TCN(Train Communication Networks) defines the set of communication vehicle buses and train buses. The MVB(Multifunction Vehicle Bus) defines the data communication interface of equipment located in a vehicle and the WTB(Wire Train Bus) defines the data communication interface between vehicles. This paper examines whether the result of on-board test is satisfied with the IEC61375-1(International Electrotechnical Commission 61375-1) which is the international standard of TCN and introduce the results.

  • PDF

Developing the Measurement System with Establishing the PHY Performance of Best Proper Cable Modem (최적의 케이블 모뎀 PHY 성능 구현 및 케이블 망 측정 시스템 개발)

  • Lee, Kyoung-Moon;Ko, Jae-Pyung;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.205-211
    • /
    • 2008
  • This paper describes the method aimed at establishing the equipment measuring the parameter of Cable Network by Best proper Cable Modem and PDA through RS232 interface. In this paper, we propose our creative experimental configuration and develope the Cable Modem (DOCSIS 2.0) superior more performing than the referred Cable Modem (DOCSIS 1.0, 1.1) and the measuring equipment of HFC network compositing of Cable Modem and PDA through RS232 interface. This equipment analyzes Upstream (U/S) and Downstream (D/S) Signal quality and generates the signal of Upstream by CW signal. The paper also provides the experimental results to check the Best Proper Cable Modem and the displayed screen for parameters for SNR, BER and the demodulated IQ diagram of 256QAM through LCD of PDA. Henceforth, it'll be possible to support a variety of the functions for E-mail, Internet, the speed test of WEB connection and the transmission of the measured result real time by PDA.

Cavity and Interface effect of PI-Film on Charge Accumulation and PD Activity under Bipolar Pulse Voltage

  • Akram, Shakeel;Wu, Guangning;Gao, GuoQiang;Liu, Yang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2089-2098
    • /
    • 2015
  • With the continuous development in insulation of electrical equipment design, the reliability of the system has been enhanced. However, in the manufacturing process and during operation under continues stresses introduce local defects, such as voids between interfaces that can responsible to occurrence of partial discharge (PD), electric field distortion and accumulation of charges. These defects may lead to localize corrosion and material degradation of insulation system, and a serious threat to the equipment. A model of three layers of PI film with air gap is presented to understand the influence of interface and voids on exploitation conditions such as strong electrical field, PD activity and charge movement. The analytical analysis, and experimental results are good agreement and show that the lose contact between interfaces accumulate more residual charges and in consequences increase the electric field intensity and accelerates internal discharges. These residual charges are trapped charges, injected by the electrodes has often same polarity, so the electric field in cavities increases significantly and thus partial discharge inception voltage (PDIV) decreases. Contrary, number of PD discharge quantity increases due to interface. Interfacial polarization effect has opposite impact on electric field and PDIV as compare to void.

The Design of Wireless Printer Interfaces for UHF band (UHF 대역 무선 프린터 공유 인터페이스의 설계)

  • 강영석;김기래
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.280-283
    • /
    • 2000
  • Users of computer interfaced with the LAN use the same printer with time sharing. Alternatively, Hey use the multi-user printer interface to print in the office which can't have LAN system due to the great expenses. Otherwise they have to connect directly moving the printer to computer. In this papaer, we present a new printer interface equipment which can interface a printer and multi computers through wireless using the radio frequency of about 430MHz. The tranceivers of the equipment consist of two part: one part is installed in parallel port of computer and other part is installed in Centronix port of printer. Their maximum data rate is 9600bps and the communication area is about 50 meters in best case.

  • PDF

A Implementation on Interface Module and Communication Protocol for Control Monitoring of the AtoN AIS (AtoN AIS 제어감시용 인터페이스 모듈과 통신프로토콜 구현)

  • Cha, Yeong-Mun;Jeong, Yeong-Cheol;Choi, Jo-Cheon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6B
    • /
    • pp.683-688
    • /
    • 2011
  • Current is change to concept that management traffic of ship os magnified gradually to near shore waters from harbor. Therefore, introducing the technology of AIS in the ground station, lighthouse, bouy, sea facilities etc.. that is support equipment for safety sailing of ship and safety security of harbor and ship administration. The operation and maintenance of AIS for aids to navigation are required to efficient method. With this actuality, sea advanced nation of EU, USA, Japan that has been apply for developing AtoN AIS equipment that is connected equipment of technology standard in IALA. Because of it is expected to depend equipment in income, that is required to domestic technology of the AtoN AIS. This paper is targeted to development that is suitable automation AtoN AIS equipment in environmental peculiarity for constructor AtoN operating administration center. It has been realization send protocol for information interchange.

A Realization on Interface Module & Communications Protocol of AtoN AIS (AtoN AIS의 인터페이스 모듈 및 통신프로토콜 구현)

  • Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.1103-1107
    • /
    • 2009
  • Lately, trend is change to concept that management traffic of ship is magnified gradually to near shore waters from harbor. Therefore, introducing the AtoN AIS technology that install AIS in the ground station, lighthouse, bouy, sea facilities etc.. that is support equipment for safety sailing of ship and safety security of harbor and ship administration. The operation and maintenance of AtoN AIS are required to efficient method. With this actuality, sea advanced nation They has been apply for developing AtoN AIS equipment that is connected equipment of technology standard in IALA. Because of it is expected to depend equipment in income, that is required to domestic technology of the AtoN AIS. This paper is targeted to development that is suitable automation AtoN AIS equipment in environmental peculiarity for construnstrunstrAtoN operating administration center. It has been realization the interface module for control and monitoring system and the communications protocol for information interchange.

  • PDF

Development of Interface Inspection System for On-board Signal Equipment (열차 차상신호 인터페이스 검사 시스템 개발)

  • Park, Jae-Young;Lim, In-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2324-2329
    • /
    • 2014
  • The inspection of distance to go train control system conducted only when train is in main line or inspecting line, that affects low work efficiency and hazard elements to safe operation. Before or after train operation, the interface test between on-board and wayside signal system must be conducted. In this paper, onboard signal interface inspection system based on the real-time automatic analysis of onboard system status information that is transmitted to the wayside system and the operation status check of the onboard signal device operates as a virtual train information that is transmitted to the onboard system have been proposed. And after building the inspection system to the inspecting track of Daejeon Subway Line 1, Panam Depot, the verification algorithm of proposed interface test and the results was presented. therefore, it has enhanced work efficiency to do not carry train operation of a half hour in test line to test on-board system.

Development of Radio Interface Module for Status Monitoring of Industrial Automation Equipment (산업 자동화 장비의 상태감시를 위한 무선 인터페이스 모듈 개발)

  • Kang, Chul-Gyu;Jeon, Min-Ho;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.4
    • /
    • pp.545-552
    • /
    • 2010
  • In this paper, we study on a radio multiple sensing interface module to accurately decide serious error sources that are happened by unexpectable problems in industrial fields, in addition, we study a reliability improvement scheme to guarantee the integrity of multiple sensing data. For multiple sensing interface module, communication drivers such as USART, TWI, ADC and GPIO-I2C are implemented. to improve the transmission reliability, reed-Solomon code is used. From the simulation result of this system in indoor environment, we confirm that the reliability of RS coded data is improved about 5 times than uncoded data. Moreover, we prove that multiple sensing interface module is suitable to diagnose error sources of industrial automaton equipment.

A Study on Improvement of User Interface(UI) based on Multi-Point Replay System (다시점 리플레이 시스템을 기반으로 사용자 인터페이스(UI) 개선방안 연구)

  • Seo, Chang Ho;Lee, Ji Eun;Choi, Seong Jhin
    • Journal of Broadcast Engineering
    • /
    • v.24 no.2
    • /
    • pp.341-352
    • /
    • 2019
  • The inconvenience of using the product weakens the competitiveness of the product and makes it difficult to obtain various users. This study proposes a 5-step evaluation method that is derived from a formal usability evaluation to suggest improvement directions for easier and more convenient manipulation of complex or inconvenient user interface. The 5-step usability evaluation method can not be applied to all broadcasting equipments, but it is expected to improve the user interface of broadcasting equipments. In addition, it is expected to provide an opportunity to more flexible access to user interface development to be applied to new application services in a variety of telecommunication convergence equipment industry, while leading the era of convergence of broadcasting industry throughout broadcasting equipment industry.

Interactive Interface Design Through VR Hand Tracking (VR 핸드트레킹을 통한 상호작용 인터페이스 설계)

  • Ju-Sang Lee;Hyo-Seung Lee;Woo-Jun Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.213-218
    • /
    • 2023
  • In order to use the VR HMD, operation through separate controllers in both hands is required. Methods for text input in VR include a method of selecting virtual keyboard keys on the screen one by one using a controller, a method of inputting through a keyboard that is a resource of a computer by connecting a computer and VR, or a method of inputting through a keyboard that is a resource of a computer by purchasing a wireless keyboard in VR and wireless keyboard connection method. As such, the text input method in current VR equipment causes inconvenience and additional costs to users. For these reasons, most of the VR-related contents are limited to simple functions such as games or viewers, and there is a risk that VR equipment will be recognized as a simple game machine. Therefore, in this study, a multi-input interface using hand tracking provided by the Oculus Quest2 device is designed and partially implemented. Through this, it is expected that various tasks such as document work and business processing as well as games can be conveniently used using VR equipment.