• 제목/요약/키워드: epoxy-coated reinforcing bars

검색결과 20건 처리시간 0.025초

철근 도장용 폴리머 시멘트 슬러리의 부착 특성 (Properties of Adhesion Tension of Polymer Cement Slurry for Coated Reinforcing Bar)

  • 김현기;이철웅;장성주;김완기;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.343-348
    • /
    • 2000
  • The purpose of this study is to clarify properties adhesive strength of polymer-cement slurry for coated reinforcing bars. The epoxy coating material is superior to performance of anti-corrosion but lately age adhesive strength between concrete raise to structural problems. However, polymer dispersion with excellent performance of elasticity and adhesion can solve this problems. From the test results. adhesion of steel with polymer cement slurry using St/BA emulsion is show excellent without concerned coating thickness, and polymer cement slurry using St/BA emulsion is show adhesion in tension 1.2~2.2MPa at polymer cement ratio 50% of more.

  • PDF

부식촉진시험에 의한 콘크리트 내의 철근의 부식특성에 관한 실험적 연구 (An Experimental Study on the Corrosion Characteristics of Reinforcing Steel in Concrete by the Accelerated Corrosion Test)

  • 배수호;정영수;김년산;권영우;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.503-507
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. In this study, the performance of corrosion protection was investigated for the test specimens using corrosion inhibitors and cathodic protection, respectively. For this purpose, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles(140 days) of wetting($65^{\circ}C$, 90% R.H) and drying period($15^{\circ}C$, 65% R.H) for the test specimens. As a result, it can be concluded from the test that the effect of corrosion inhibitor was found to be variable with products, the cathodic protection method was found to be independent of salt concentration in concrete.

  • PDF

방청제에 의한 콘크리트 내의 철근 방식법에 관한 실험적 연구 (An Experimental Study on the Corrosion Protection Method of Reinforcing Steel in Concrete by Using Corrosion Inhibitor)

  • 배수호;정영수;권영우;김년산;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.710-713
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. The most economical method of them will be the corrosion protection method using corrosion inhibitor as concrete admixture. Therefore, the purpose of this research is to investigate the performance of corrosion protection of ordinary strength and high strength concrete using corrosion inhibitor, respectively. For this purpose, after manufacturing ordinary strength and high strength concrete with and without corrosion inhibitor, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles (140 day) of wetting ($65^{\circ}C$, 90% R.H.) and drying period ($15^{\circ}C$, 65% R.H.). As a result, th high strength concrete using corrosion inhibitor showed an excellent performance of corrosion protection.

  • PDF

에폭시 도포철근의 내 부식성능에 관한 실험적 연구 (An Experimental Study on Corrosion Resistance of Epoxy Coated Reinforcements)

  • 오병환;엄주용;권지훈
    • 콘크리트학회지
    • /
    • 제4권4호
    • /
    • pp.161-170
    • /
    • 1992
  • 근래 들어 철근 콘크리트에 있어서의 철근부식이 관심의 대상이 되고 있는데 그이유는 이 현상이 실제 구조물에서 광범위하게 발생함이 확인되었고 이로 인한 보수비용이 급증하였기 때문이다. 철근의 부식이 처음 거론된 것은 해양구조물과 내화학성 구조물에서였고 최근 들어서는 교량상판, 주차공간등 염기에 노출되어 철근 부식이 우려되는 각 종의 구조물에 광범위하게 그 대책이 연구되기에 이르렀다. 이와같은 철근부식이 제어방법으로는 첫째로 콘크리트의 수밀화를 들 수 있고 다음으로 콘크리트의 표면을 처리하거나 피복두께를 늘이는 방법이 있다. 마지막으로 철근자체에 방청성능을 직접 부여하여 방법에 속하는 에폭시 도포 철근의 기본적인 방청성능을 고찰하기 위해 수행되었다. 연구결과 에폭시 도포철근의 방청성능은 매우 우수함을 발견하였고 앞으로 활용이 기대되고 있다.

Hybrid형 폴리머 시멘트 슬러리로 도장한 철근의 부착강도와 부식저항성 (Bond Strength and Corrosion Resistance of Coated Reinforcing Bar Using Hybrid-Type Polymer Cement Slurry)

  • 조영국
    • 한국건축시공학회지
    • /
    • 제8권3호
    • /
    • pp.93-99
    • /
    • 2008
  • The purpose of this study is to evaluate the bond strength and corrosion resistance of coated reinforcing bar using hybrid-type polymer cement slurry(PCS). PCS coated steels, which is made from two types of polymer dispersions such as St/BA and EVA are prepared, and tested for bond strength and various corrosion resistances such as autoclaved cure, carbonation and H2SO4 solution. From the test results, the bond strength of PCS coated reinforcing bar using ordinary portland cement at 1-5, 2-1 and 4-5 of mixes is higher than that of uncoated regular steel. However, bond strength of almost PCS coated reinforcing bars using ultra rapid high strength cement is higher than that of epoxy coated bar, is also in ranges of 102% to 123% compared to that of uncoated regular steel. In autoclaved accelerating test, the ratio of corrosion of uncoated regular steel is increased with the increase in NaCl content, but the corrosion of PCS coated steel was very small. In the acceleration test for carbonation, increasing the amount of NaCl the corrosion of coated steel did not produce. The corrosion of uncoated regular steel is increased with the increase in the amount of NaCl. It can be seen that the NaCl following the acceleration test for carbonation can lower the corrosion resistance of concrete. As a result, the corrosion of steel largely is affected by the acceleration curing, chloride ion penetration and carbonation and shown more severe corrosion by applying complex factors. These corrosions of steel can be suppressed by the coating of PCS.

Study of Corrosion-Induced Failure Mechanisms of Epoxy Coated Reinforcing Steel (Parts I and II)

  • Lee, Seung-kyoung
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.396-401
    • /
    • 1995
  • Epoxy coated reinforcing steels (ECRs) were acquired from ten sources and coatings from each source were initially characterized in terms of defects, thickness, solvent extraction weight loss and hardness. Testing involved exposure in three aqueous solutions at elevated temperature (8$0^{\circ}C$) and in chloride-contaminated concrete slabs under outdoor exposure, It was found that the density and size of coating defects was the promary factor affecting ECR performance. The equivalent circuit analysis using electrochemical impedance spectroscopy (EIS) data indicated that the impedance response for well-performing ECR specimens showed no signs of active degradation at the interface although diffusional processes similar to those noted for poorly performing bars occurred here. Experimental results also indicated a relationship between corrosion behavior and bar source. Weight loss upon solvent extraction correlated with impedance reduction from hot water exposure. Coating defects during most of the tests, especially in high pH solutions containing chloride ions. ECRs with excessive coating defects, either initially present or ones which developed in service, performed poorly in every test category regardless of source. Forms of coating failure were extensive rusting at defects, blistering, wet adhesion loss, cathodic delamination, underfilm corrosion and coating cracks. These occurred sequentially or concurrently, depending on the condition of the ECR and nature of the environment

  • PDF

FRP Re-bar 보강 직사각형 단면 콘크리트 보의 구조적 거동 및 설계방법에 관한연구 (A Study on the Structural Behavior and Design Criteria of FRP Re-bar Reinforced Rectangular Concrete Beam)

  • 주형중;옥동민;박주경;윤순종
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.276-279
    • /
    • 2005
  • FRP Composite materials are widely applicable in the construction industries as a load-bearing structural element or a reinforcing and/or repairing materials for the concrete. In this paper, we presented the flexural behavior of FRP Re-bar and steel reinforced concrete beams and only FRP re-bars reinforced concrete beams. FRP Re-bar manufactured by different fibers but the same vinylester resin. Also, surface of FRP Re-bars is coated garnet and glass fiber by epoxy to increase the adhesive to concrete. Experimental investigation pertaining to the load-deflection and load-strain characteristics of two classfied specimens is presented and the theoretical prediction is also conducted. In the investigation, the effects of FRP Re-bar reinforcement are estimated. The experimental results arc compared with theoretical predictions. Good agreements arc observed.

  • PDF

하이브리드형 방식 폴리머 시멘트 슬러리의 인장특성 및 접착성 (Tensile Properties and Adhesion of Hybrid-Type Anti-Corrosion Polymer Cement Slurry)

  • 조영국
    • 콘크리트학회논문집
    • /
    • 제20권5호
    • /
    • pp.635-642
    • /
    • 2008
  • 건설구조물에서 보통철근의 부식을 방지하기 위하여 에폭시 도장 철근이 널리 사용되고 있다. 그러나 에폭시 도장철근은 성능과 코스트 면에서 불리하며, 특히 취성적이고, 부착성 및 현장 가공성 등의 취약점 때문에 현장에서 사용상의 제약을 받고 있다. 본 연구는 에폭시 도장 철근을 대체할 수 있는 도장재료로서 유기계 폴리머와 시멘트의 무기계를 혼합한 하이브리드 (hybrid)형 폴리머 시멘트 슬러리를 개발하기 위한 것으로서, 특히 인장특성과 접착성에 관한 연구이다. 폴리머 시멘트 슬러리는 4종류의 폴리머 디스퍼션과 혼화재로서 플라이애쉬와 실리카퓸을 혼입하여 제작되었으며, 도장두께, 인장특성, 접착성 및 내굴곡성 시험을 실시하였다. 연구결과, 폴리머 시멘트 슬러리의 점도는 폴리머 디스퍼션의 종류에 따라 크게 영향을 받았으며, 플라이애쉬를 혼입함에 따라 약간 감소하였다. 또한 폴리머-결합재비 100%에서 폴리머 시멘트 슬러리의 적정 도장두께가 확보되었으며, 도장두께는 물-결합재비와 폴리머-결합재비에 의해 다양화 할 수 있었다. 철근의 도장을 위한 적정 도장 두께는 부착강도, 접착성 및 내굴곡성을 고려할 때, 보통 $150{\sim}250{\pm}50{\mu}m$ 범위였다. 본 연구에서 폴리머 시멘트 슬러리의 인장특성 및 접착성, 그리고 도장강의 내굴곡성은 양호하게 평가되어, 향후 에폭시 도장철근을 대체할 수 있는 재료로 사용가능성을 확인하였다.

규사 코팅 방법에 따른 FRP Hybrid Bar의 부착강도 평가 (Evaluation of Bond Strength for FRP Hybrid Bar According to Coating Methods using Silica Sands)

  • 정규산;박기태;유영준;서동우;김병철;박준석
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.118-125
    • /
    • 2017
  • 본 논문은 FRP Hybrid Bar의 최적 부착 성능 도출을 위한 실험 결과를 나타낸다. FRP Hybrid Bar는 이형 철근의 부식문제를 해결하기 위하여 이형 철근 외측에 유리섬유를 감싸 만들어졌다. 콘크리트와의 부착 성능 향상을 위해 매끈한 FRP Hybrid Bar 표면에 수지와 규사를 이용하여 코팅하였고 수지의 종류 및 점도, 그리고 규사의 크기를 실험 변수로 하여 FRP Hybrid Bar의 부착 성능을 실험적으로 평가하였다. FRP Hybrid Bar의 부착 성능 평가를 위해 한 변의 길이가 200 mm인 정육면체 콘크리트 블록에 FRP Hybrid Bar를 매립하였고, 인발 실험을 통하여 FRP Hybrid Bar와 콘크리트의 계면에서의 최대 하중과 슬립을 측정하였다. 실험 결과로부터, 각 실험 변수에 따른 최대 하중 및 부착 강도를 산정하였고 FRP Hybrid Bar의 부착 성능이 가장 우수한 수지 종류 및 점도, 그리고 규사 크기를 도출하였다. 에폭시 수지와 5호 규사를 사용한 실험체의 최대부착강도는 이형철근의 최대부착강도 대비 약 35% 정도 증가되었다.

해안매립지 하수처리시설물에 적용한 저발열시멘트 콘크리트의 내화학성 평가 (Chemical Resistance of Low Heat Cement Concrete Used in Wastewater Treatment Structures Built on Reclaimed Land)

  • 정용택;이병재;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.113-119
    • /
    • 2019
  • 해안매립지에 건설되는 구조물은 해수로부터 유입되는 염소 및 황산염 이온 등의 화학적 침식에 의한 영향을 복합적으로 받는다. 염해는 콘크리트 내부의 철근을 부식시켜 구조물의 성능을 저하시킨다. 또한, 하수처리시설에서는 내부에서 발생되는 황산염에 의해 콘크리트가 열화되는 문제점을 가진다. 따라서 본 연구에서는 해안매립지에 건설되는 하수처리구조물에 적용할 수 있는 혼합형 저발열시멘트의 특성 및 내화학성을 평가하였다. 실험결과, 모든 배합조건에서 목표슬럼프 및 공기량을 모두 만족하였다. 동일 배합조건에서 LHC사용시 OPC 보다 슬럼프는 증가되고, 공기량은 감소하는 경향을 나타내었다. 압축강도 시험결과, 초기재령에서는 OPC의 강도발현이 빨랐으며, 28일 이후 LHC가 OPC보다 높은 강도를 나타내었다. 염소이온침투저항성 평가결과, LHC-B의 경우 56일 재령에서, "매우낮음" 단계의 염소이온침투저항성을 나타내 LHC의 내염해성을 확인하였다. 내화학성 평가 결과, 에폭시 처리 하지 않은 경우 LHC를 적용한 경우, OPC보다 약 18%정도 내화학성이 개선되는 것으로 나타났으며, 콘크리트 표면에 에폭시 공법 적용시 강도보존율이 95% 이상 확보 가능한 것으로 확인되었다.