• Title/Summary/Keyword: environmental standards

Search Result 2,007, Processing Time 0.026 seconds

Derivation of Soil Fluorine Standards Based on a Human Health Risk Assessment Method (위해성 평가 기법에 따른 토양 불소 기준안 연구)

  • Seung-Woo Jeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.3
    • /
    • pp.14-22
    • /
    • 2024
  • This study established risk-based fluoride soil contamination standards according to the Korean Soil Contaminant Risk Assessment Guidelines (SRAG). Ten exposure scenarios were evaluated, broadly categorized into Scenario 1, which used the default parameters from the current SRAG, and Scenario 2, which used the latest exposure factors and bio-concentration factors. Fluoride soil standards corresponding to a total hazard index (HI) of 1.0 were determined for each scenario. For children in agricultural areas, the derived risk-based soil fluoride standard was 70 mg/kg for Scenario 1 and 27 mg/kg for Scenario 2. In industrial areas, the risk-based fluoride soil standard was 2200 mg/kg in Scenario 1 and 2300 mg/kg in Scenario 2. This study clearly demonstrated that the crop ingestion exposure pathway exerted predominent influence on the estimated human health risk standards. Additionally, using the Added Risk Approach and considering soil background concentrations, the total fluoride soil standards for residential areas ranged from 232 mg/kg to 444 mg/kg, while the standards for industrial areas ranged from 2405 mg/kg to 2674 mg/kg.

Review and Analyses of International Standards and Implications for Implementing Korean Hydrogen Charging Station in UAE (한국형 수소충전소의 UAE 구축을 위한 인허가 절차 검토 및 적용 방안 모색)

  • YOUNG-JI BYON;SEUNG HWAN KIM;GOANG SUNG JIN;YOUNG WOOK SEO;YOUNG SOON BAEK
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.623-630
    • /
    • 2023
  • Recently, a hydrogen charging station-related memorandum of understanding (MOU) was signed between Korea Transport Institute and United Arab Emirates (UAE) Ministry of Transport in Abu Dhabi, creating a foundation for exporting green hydrogen charging stations and hydrogen powered public transit buses developed with Korean technology to Abu Dhabi. Reliable construction and operation of the charging stations require a thorough review on associated standards and legal requirements. In particular, it is essential to analyze currently effective standards related to hydrogen production, hydrogen vehicle charging, and hydrogen charging stations. This paper specifically focuses on comparative analysis of hydrogen-related standards in the UAE and the Republic of Korea. Similar to UAE, Korean hydrogen charging station-related standards follow International Organization for Standardization (ISO) standards. From real-life experiences in developing and operating charging stations, even more essence of ISO standards have been adopted in Korean standards than UAE. In particular, ISO standards related to fire prevention are additionally included in Korea. This paper also suggests procedural and administrative strategies for enabling application of Korean hydrogen charging station-related standards in UAE.

The State of Marine Pollution in the Waters adjacent to Shipyards in Korea - 2. Assessment of the Pollution of Heavy Metals in Seawater around Major Shipyards in Summer 2010 (국내 조선소 주변해역의 해양오염 현황 - 2. 2010년 하계 대형조선소 주변 해수의 중금속오염 평가)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.9-17
    • /
    • 2015
  • In order to elucidate the current state of marine pollution of heavy metals around major shipyards in Korea, seawater samples were collected at eleven sampling stations and four control stations around 4 major shipyards located in the southeastern coast of Korea in summer 2010, and 6 kinds of metals such as copper(Cu), zinc(Zn), iron(Fe), cadmium(Cd), lead(Pb) and mercury(Hg) in seawater samples were analyzed. The analyses of heavy metals in seawater showed that the mean Cu concentrations in seawater around 4 major shipyards were in the range of $0.817{\sim}1.638{\mu}g/L$ which were lower than Korean environmental standards of $20{\mu}g/L$ for the protection of human health(PHH) and of $3{\mu}g/L$ for short-term protection of marine ecosystem(SPME) but higher than Cu concentration at control station by a factor of up to 2.75. The mean Zn concentrations were in the range of $0.228{\sim}0.567{\mu}g/L$ which were lower than Korean environmental standards of $100{\mu}g/L$ for PHH and $34{\mu}g/L$ for SPME but higher than Zn concentration at control station by a factor of up to 5.91. The mean Fe concentrations were in the range of $3.332{\sim}7.410{\mu}g/L$ which were higher than Fe concentration at control station by a factor of up to 6.75. The mean Cd concentrations were in the range of $0.013{\sim}0.028{\mu}g/L$ which were lower than Korean environmental standards of $10{\mu}g/L$ for PHH and $19{\mu}g/L$ for SPME but higher than Cd concentration at control station by a factor of up to 2.33. The mean Pb concentrations were in the range of $0.007{\sim}0.126{\mu}g/L$ which were lower than Korean environmental standards of $50{\mu}g/L$ for PHH and $7.6{\mu}g/L$ for SPME. The mean Hg concentrations were in the range of $0.002{\sim}0.004{\mu}g/L$ which were lower than Korean environmental standards of $0.5{\mu}g/L$ for PHH and $1.8{\mu}g/L$ for SPME. Although the concentrations of metals such as Cu, Zn and Fe which were used in shipbuilding works were lower than Korean environmental standards for PHH and SPME, the fact that the concentrations of Cu, Zn and Fe at sampling stations around major shipyards were higher than those at control stations implies that the works in shipyards had some effects on marine water quality around shipyards. Therefore, marine environment management such as the prevention and control of the discharge of various pollutants from shipyards is required on national level.

Overhead Crane Controllers and Ergonomic Problems in Industrial Field (산업현장의 천장크레인 조작장치 사용 현황과 인간공학적 문제점)

  • Park, Jae Hee;Kim, Seung Hee
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.90-97
    • /
    • 2017
  • Overhead cranes are the most widely used and have been identified as one of the main causes of fatal accidents. Although structural, mechanical and electrical safety standards for overhead cranes have been established to some extent, ergonomic standards related to crane controllers are rarely established. As a result, many crane accidents are reported to be caused by operator's error. To investigate the actual use of crane controllers in the industrial field, we surveyed 82 overhead cranes in 15 workplace and interviewed workers operating them. This study has presented the ergonomic problems related to the crane controllers in the field. As a result of investigation, it was found that the direction control signs, the sign language, and the button layout on the pendant switches and remote controllers are not standardized, which can cause a human error. To reduce human errors in overhead crane operation, ergonomic standards for controllers should be reflected on the government legislation or standards.

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.