• Title/Summary/Keyword: environmental facility

Search Result 1,796, Processing Time 0.031 seconds

The Study on Damaged Hanbuk Mountain Range in Gyeonggi-Do (경기도 한북정맥 훼손유형 연구)

  • Seo, Jung-Young;Lee, Yang-Ju
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2010
  • This study is for Hanbuk Mountain Range within Gyeonggi province which is to propose the conservation plan by each damage pattern through site survey of the mountain range. The damage patterns are classified by siding, pointing and lining. The total damaged area is 103 areas: The siding pattern is damaged by developing farmland, mineral and quarry mining, dam, large scale development complex and cemetery park; The pointing pattern is including the development of road, transmission tower and way and mountaineering trail; The construction of electricity and communication facility, military facility, mobile communication station, heliport and shelter. The damages by developing road and large scale development complex are the most cause, and military facility, dam and reservoir, and residential area are the main causes, respectively. One of the compromised situation Hanbuk-Mountain Range usage as per section 7 section (18.45%), 12 section (18.45%) is the largest number of compromised has been surveyed, undermine the situation if you look at the usage by the road 25 locations (24.22%), military facilities and dam and reservoir to undermine this 11 established respectively (10.68%) were the most undermine. Therefore, this research propose the conservation plan as follow: first, need to understand, educate and publicize on Hanbuk-Mounatin Range; second, manage through the regulations and ordinance of Gyeonggi province; third build and expand the law for protecting Baekdu-Great Mountain Range.

Real-time large-scale hybrid testing for seismic performance evaluation of smart structures

  • Mercan, Oya;Ricles, James;Sause, Richard;Marullo, Thomas
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.667-684
    • /
    • 2008
  • Numerous devices exist for reducing or eliminating seismic damage to structures. These include passive dampers, semi-active dampers, and active control devices. The performance of structural systems with these devices has often been evaluated using numerical simulations. Experiments on structural systems with these devices, particularly at large-scale, are lacking. This paper describes a real-time hybrid testing facility that has been developed at the Lehigh University NEES Equipment Site. The facility enables real-time large-scale experiments to be performed on structural systems with rate-dependent devices, thereby permitting a more complete evaluation of the seismic performance of the devices and their effectiveness in seismic hazard reduction. The hardware and integrated control architecture for hybrid testing developed at the facility are presented. An application involving the use of passive elastomeric dampers in a three story moment resisting frame subjected to earthquake ground motions is presented. The experiment focused on a test structure consisting of the damper and diagonal bracing, which was coupled to a nonlinear analytical model of the remaining part of the structure (i.e., the moment resisting frame). A tracking indictor is used to track the actuator ability to achieve the command displacement during a test, enabling the quality of the test results to be assessed. An extension of the testbed to the real-time hybrid testing of smart structures with semi-active dampers is described.

A Study on Tendency of Color Consciousness and Preference for Healthcare Environmental Color (보건의료 색채환경을 위한 색채 의식 및 선호 경향 연구)

  • Park, Heykyung;Choi, Inyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.83-91
    • /
    • 2016
  • This study is a basic research to suggest user-centered healthcare environmental color, which aims to analyze tendency of color consciousness and preference depending on the user characteristics (generation, gender, residential area, and environment). For this purpose, this study constructed an analysis tool through the literature review with regard to environmental color of healthcare facility and influential factors of color preference. Besides, an online survey regarding general usage and satisfaction, health related color consciousness, and color preference tendency of healthcare facility was conducted targeting from 20s to 60s, total 1,500 persons. The results of this study are as follows: (1) The usage and satisfaction of healthcare facilities were higher for older generation and accessible urban area. (2) The respondents were aware that color and health are related, recognizing 'green' as healthy and stress relieving color. Besides, 'natural' and 'clear' was the highest in health related color image. 'Light' which relates to vitality was high as well for older generation. (3) In the color preference tendency survey, hue PB was generally the most highly preferred, in details, younger generation preferred B and R while older generation preferred G. The survey also showed high value and chroma were preferred, while female and younger generation preferred high value of 9.0 and low chroma close to achromatic color, which presented older generation preferred vivid color.

An Evaluation of User's Facility and Suggestion for the Improvement on the Interior Design of Metropolitan Railroads Trains - Focus on the opening 14 metropolitan railroad lines in Seoul through checklist - (도시철도 차량 실내의 이용자 시설 평가와 개선방향 - 체크리스트를 통하여 수도권 노선에 운행 중인 14개 철도 차량을 대상으로 -)

  • Moon, Suh-Hyun;Kim, Gu-Seul;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.11-20
    • /
    • 2010
  • User-oriented Design is necessary in planning the interior design of Metropolitan Railroads trains, since this is a typical means of transportation in this modem society and all ages people with different body scale use this facility. However, there are little studies about facility panning and zoning of Metropolitan Railroads train considering users. Therefore, in this study, after completing the checklist based on the current legal standards of facility installation of South Korea and Japan, we examined user's facility and suggest several improvement of the opening 14 metropolitan railroad lines in Seoul. Then, we evaluated this facilities according to 41 standards; general facility(24 standards), safety facility(4 standards), guide facility(11 standards), other facility(4 standards). The result of this study may be summarized as follows. 1) General facility has to be designed to obtain lots of room for storage and this facility should be fixed up tightly with secure system. 2) Safety facility should be designed to minimize a difference of floor-level between threshold of train and ground. Also, using various color and material could help passengers to distinguish different space and facility. 3) Guide facility should be designed to guide passengers to the accurate direction with proper sign design in the pathway of Metropolitan railroad train. Also, more various color, which based on the research about physiological and psychological effect, should be used to guide people. 4) Other facility should equip more visual system using common good and informative contents. Through this study, we try to understand the current interior physical condition of Metropolitan Railroads trains. However, for future studies, it is expected to supplement evaluation standards considering aesthetic design, environmental improvement of indoor air quality and the satisfaction and demand of Metropolitan Railroads trains.

Identification of Major Fungi and Bacterial Species in Solid Medium Drainage for Circulating Hydroponics System (수경재배 배액 재이용을 위한 주요 곰팡이 및 박테리아 종 파악)

  • Lee, Donggwan;Son, Jinkwan;Kang, Taegyeong;Jang, Jaekyung;Park, Minjung;Lee, Taeseok;Lim, Ryugap
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1109-1123
    • /
    • 2020
  • In this study, the amount of harmful fungi and bacteria contained in the drainage and culture medium from the paprika hydroponic facility is identified. In addition, by proposing the necessity of effective purification of discharged drainage, this study attempted to confirm the possibility of drainage reuse. Finally, this study provides basic data on the basis for calculating the need for purification facilities in the future, as well as improvements in horticulture facility for sustainable agriculture. As a result of the analysis, a total of 12 types of fungi were detected in paprika medium and 10 types of fungi were detected in the drainage, and their densities were 130 and 68, respectively. Among the fungi detected in the media and drainage of the paprika hydroponic facility, the fungi with the highest detection frequency are Fusarium, Phytophthora, and Pythium. In the case of bacteria, a total of 2 types of bacteria were detected in the paprika facilities, and the density was 28 and 23, respectively. Therefore, in order to reuse the drainage and settle the circulating hydroponic cultivation system, a water treatment process capable of appropriate treatment is required.

A Study on the Planning Criteria for Thalassotherapy Facility (해양치유시설 계획기준에 관한 연구)

  • Lee, Han-Seok;Kang, Young-Hun;Seong, Hai-Min
    • Journal of Navigation and Port Research
    • /
    • v.44 no.1
    • /
    • pp.20-31
    • /
    • 2020
  • The purpose of this study was to provide planning criteria for the thalassotherapy facility. Among the various contents of the planning criteria, the crucial parts of the thalassotherapy facility planning are the location, facility environment, and room space. To do this, we first examined the characteristics of the thalassotherapy facility and inquired about the thalassotherapy resources and treatments that are the basis of the thalassotherapy facility planning. And then, the overseas qualification criteria related to thalassotherapy facility were analyzed. Based on the above research results, the criteria for the thalassotherapy facility planning on location, facility environment, and spaces of rooms are presented. The location is within 1km of the coastline, where there is no pollutant emission facility, and the climate conditions are maintained more than 80% throughout the year below 'caution' level of the thermal sensation index and sensory temperature. The water quality of the facility environment meets the stricter criteria among the domestic standards or ISO 17680 standards, and the air quality is 60% of the atmospheric environment standard of the 「Framework Act on Environmental Policy」 and SO2, NO2, O3 and PM10 concentration shall ensure that the annual number of exceeding standards meets the EU standard, and noise is less than 50dB per daytime, 40dB per night. Therapy spaces have to meet the standards of the 「Building Act」, the working standards of architectural planning and international standards according to their function and use.

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

Investigation on the operational state of the public food waste treatment facilities and suggestions on their efficient operational management (음식물류폐기물 공공 자원화시설의 운영실태 조사를 통한 처리공정별 효율적인 운영방안 검토)

  • Jang, Yun-Hyeok;Park, Joon-Seok;Kim, Joung-Dae;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.47-56
    • /
    • 2010
  • At present, 265 national food waste recycling facilities have been operated by public facilities 95 and private facilities 160. it has continuously installed a food waste treatment facility from 1997. The government set up and implemented guidelines and inspection standards for the installation and operation of the facilities. However, unclear detailed examination items, designs and process standards for the installation procedures of the facilities are causing problems due to the unskilled operation management system, decrease in efficiency and defects of a facility. This study conducted mail and site surveys on 95 public food waste recycling facilities that it suggest the ways to operate facilities which minimize problems. At the result of investigation, a pre-treatment facility was not installed 2 systems(2 inputting facilities) and hopper covers and food was overloaded. also the transportation amount was excessive. In case of a main treatment facility, the secondary environmental pollution was caused by inexperienced operation and the efficiency of the facility was reduced due to excessive input of food. also the operation management standards of the facilities were inappropriate. The odor and food waste leachate treatment facility is investigated as problems that are unskilled operation, lack of regular inspection and inappropriate capacity of the treatment facility. Based on the problems found through the investigation, it suggested some ways of efficient operation. this study might contribute to minimize mistakes and defects and improve the efficiency of install and operation course of food waste recycling facilities through finding.

A Study of Assessment on Occupational Noise Environment for Metal Working Facility (절삭설비의 소음환경평가에 관한 연구)

  • 이내우;허현철;전성균;이진우
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.457-464
    • /
    • 1999
  • To develop managing guidance of occupational noise exposure for metal working facility, we have studied about drafting contour map of noise exposure, methods of noise assessment and actual calculation method of time weighted noise exposure. Therefore we have suggested that contour maps of noisy workplace are very important for controlling metal working fluid facility and two kinds of noise assessment method, so called, personal andstatic exposure are necessary to avoid argument between workers and managing group. Finally we would like recommend that the Korean specification of noise exposure should be modified to protect ONIHL(oocupational noise induced hearing loss).

  • PDF

Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings (다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구)

  • 김윤신;이은규;엽무종;김기영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.3-5
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991-February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001-June 2001 in Seoul. The results were as follows : 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. 2. The average of staphylcocci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were Underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites

  • PDF