• 제목/요약/키워드: environmental facility

Search Result 1,796, Processing Time 0.027 seconds

Estimation of stormwater interception ratio for evaluating LID facilities performance in Korea

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.19-28
    • /
    • 2019
  • To minimize the impact of urbanization, accurate performance evaluation of Low Impact Development (LID) facilities is needed. In Korea, the method designed to evaluate large-scale non-point pollution reduction facilities is being applied to LID facilities. However, it has been pointed out that this method is not suitable for evaluating the performance of relatively small-scale installed LID facilities. In this study, a new design formula was proposed based on the ratio of LID facility area and contributing drainage area, for estimating the Stormwater Interception Ratio (SIR) for LID facilities. The SIR was estimated for bio-retentions, infiltration trenches and vegetative swales, which are typical LID facilities, under various conditions through long-term stormwater simulation using the LID module of EPA SWMM. Based on the results of these numerical experiments, the new SIR formula for each LID facility was derived. The sensitivity of the proposed SIR formula to local rainfall properties and design variables is analysed. In addition, the SIR formula was compared with the existing design formula, the Rainfall Interception Ratio (RIR).

Concentration level of Volitile Organic Compounds about the Air of Source Boundary Site in Seongseo Industrial Complex (대구성서산업단지 발생원부지경계 대기 중 휘발성유기화합물질의 농도수준)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • The concentrations of volatile organic compounds(VOCs) in the ambient air were measured at various point(Source, source boundary) in Seongseo industrial complex during May to November 2003. Air samples were collected in Silcocan canister $(1{\ell},\;6{\ell})$ and analyzed using a cryogenic preconcentration system and GC/MSD. We identified 37 species by the US EPA(TO-14 method). The result showed a variety distribution of the con­centration, Higher concentrations of BTX, Styrene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene were observed at the sampling sites. They seemed to be emitted from the facility of wastewater treatment, reaction tank of chemistry factory and facility of Tenter. The concentrations of VOCs contents in Seongseo industrial complex were generally higher than those in Yeosu complex and Ulsan complex, although those were similar in Sihwa­Banwol complex.

The Effect of Branches on Kumho River's Water Quality (지류의 수질이 금호강 본류의 수질에 미치는 영향에 관한 연구)

  • Yang, Duk Seok;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.21 no.10
    • /
    • pp.1245-1253
    • /
    • 2012
  • In this study, how branches of Kumho River affect to the water quality on Kumho River was investigated. Water samples from six sampling points at Kumho River and three at each branch were taken from Dec. 2009 to Dec. 2011. As results, Namcheon affected BOD and T-P concentrations on Kumho River while Sincheon did only T-P concentrations. However, the water quality of Kumho River was improved because of Sincheon in terms of BOD and COD concentrations. This was the results from management of Sincheon wastewater treatment facility and Jisan wastewater treatment facility which might be the best example for managing wastewater treatment facilities. Dalsecheon would not affect the water quality of Kumho River although it had bad conditions of water quality because of lack of its water quantity comparing to Kumho River's.

Survey on environmental condition and health state of laboratory mouse in conventional facility (일반시설에서 사육되는 마우스의 품질향상을 위한 기초조사 연구)

  • Lee, Heungshik S.;Seung, Rho Hyun;Kim, Kyungjin;Kim, Chul-kyu
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.3
    • /
    • pp.611-625
    • /
    • 2000
  • For the improvement of quality control of laboratory mouse, we investigated the environmental condition, histopathological findings and serological test using ELISA to mouse hepatitis virus(MHV), Mycoplasma pulmonis(MP), Clostridium piliforme(TZ) and Sendai virus (HVJ) of ICR, C57BL/6, CBA and C3H/He mice that were supplied from conventional laboratory animal facility. 1. The ammonia concentration of facility was below the recommended concentration, 15ppm, by the KNIH, and the room temperature($21{\sim}23^{\circ}C$) and relative humidity(40~60%) was optimum range recommend by the Ministry of Health and Welfare, respectively. 2. The incidence rate of inapparent disease was 86.6% and the major findings in the liver were vacuolar degeneration with nucleic pleomorphism. The lung was shown the thickening of alveolar wall and interstitial pneumonia with congestion. The kidney and spleen were observed the mild congestion and extramedullary hematopoiesis, respectively. 3. The positive reaction rates against MHV and MP in serological test was 97.9% and 37.5%, respectively but HVJ and TZ were negative. These results suggest that laboratory mice could be infected with MHV and MP under conventional environments. Therefore we recommend to select thoroughly inapparent infected mice and to convert conventional system into SPF facility as soon as possible.

  • PDF

The Externality of an Unwelcomed Facility on the Nearby Multi-family Houses: A Case Study of Dangin-Ri Power Plant (기피시설이 인근 공동주택(연립, 다세대)에 미치는 외부효과 - 당인리 화력발전소를 사례로 -)

  • Kim, Chul-Joong;Song, Myung-Gyu
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.729-745
    • /
    • 2011
  • The purpose of this paper is to estimate the external diseconomies of an unwelcomed facility on the nearby houses. The facility and the area studied are Dangin-Ri power plant in Mapo-Gu, Seoul and the residential district surrounding it respectively. The nearby housing prices have been changed according to the time and circumstances of the public announcements about the reconstruction or removal plans of the plant. These price changes are regarded as the capitalized values of the external diseconomies due to the plant. This study is based on the hedonic price theory in order to estimate the diseconomies in monetary value. The tools for the estimation are four models of multiple regression with the transaction price as the dependant variable and various housing characteristics including the external effects of the plant as the independent variables. The sample analyzed is 833 house transactions for the past 5 years in the research area. The facts found are as follows; First, the most suitable functional form for the estimation is confirmed to be the linear model. Second, there are significant differences in influence on the housing values among the independent variables, that is, locational characteristics, physical features, and environmental changes with time. Third, the external diseconomy is estimated as \80,137,807 in case that the plant would be reconstructed in the underground of the present site, whereon a substitutional public park would be constructed and as \59,142,248 in case that the plant would move away.

Development of Location based Augmented Reality System for Public Underground Facility Management (공공지하시설물 관리를 위한 증강현실 시스템 개발)

  • Lee, Hyo-Jin;Kim, Ji-Sung;Seo, Ho-Seok;Cho, Young-Sik
    • Journal of Digital Contents Society
    • /
    • v.19 no.2
    • /
    • pp.237-243
    • /
    • 2018
  • Most of public underground facilities are installed under the ground, thus it is difficult to recognize the accurate location even with the drawings. Studies are conducted to understand exact position of underground facilities using augmented reality. However, in those studies, establishing of additional 3D object model database is needed when AR system is used at field. Because most of public underground facility information are established as 2 dimensional. In this study, AR system is developed as mobile application which can use original 2D underground facility data to transfer 3D AR data automatically without additional 3D database establishment.

Suggestion the Rational Items with Comparison and Review for Designing of Buffering Retention Facility (완충저류시설 설계 시 고려사항 분석을 통한 합리적 항목 제시)

  • Ahn, Sang Hyun;Jung, Younghun;Kwak, Jaesang;Um, Myoung-Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.1
    • /
    • pp.23-34
    • /
    • 2022
  • Korea Government promotes the installation of buffering retention facility to protect the water environment and prevent the environmental contamination event by toxic materials. Although the buffering retention facility is very important to protect the natural environment through the retention of accidental pollution and initial runoff, much study has not been done to suggest the guide line for the design of the facility. In this study, we suggested the rational items for the design of buffering retention facility based on many experts after we investigated and compared the previous results of many design materials.

A Study on Treatment Measures of Carcass Disposal Site Leachate into the Livestock Manure and Sewage Treatment Facilities using NIER-MASS program (NIER-MASS 프로그램을 이용한 가축매립지 침출수 연계처리 방안 연구)

  • Jeong, Dong-Hwan;Lee, Chulgu;Shin, Jinsoo;Kim, Hyunwoo;Yoon, Soohyang;Kim, Yongseok;Yu, Soonju;Kim, Shinjo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.725-734
    • /
    • 2012
  • The outbreak of foot and mouth disease in November 2010 raised many social, economic and environmental issues and water contaminations by leachate from carcass disposal sites particularly emerged as a serious concern. In oder to efficiently handle these problems, a critical method is required to transport leachate to livestock manure and sewage treatment plants and purify it. This study aims to present the best applicable method to transport leachate from carcass disposal sites into livestock manure and sewage treatment facilities. We investigated the biological and chemical characteristics such as BOD, COD, SS, TN, TP and Total coliforms. Current conjugated treatments in livestock manure and sewage treatment plants was studied by surveying the operations of those facilities. The NIER-MASS(National Institute of Environmental Research - Mass Balance Evaluation System of Sewage Treatment Facilities) program was applied to present the best conjugated treatment method through estimating the maximum daily load to meet the water quality standards in effluent.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

A Study on Improvement Method by Environmental-Friendly Planning Elements of High-rise Residential Complex (초고층 복합주거단지의 친환경 계획요소 평가를 통한 개선방안에 관한 연구)

  • Hwang, Jung-Man;Lee, Joo-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1522-1530
    • /
    • 2014
  • High-rise residential complex type is getting important as new town development and urban regeneration in the downtown area. However, literature review of high-rise residential complex and research on satisfaction analysis of real residents are lack. Therefore, this paper is analyzing environmental friendly planning elements of high-rise building as housing subdivision, inside of building, facility, and maintenance by a survey on experts. The purpose of this paper is to suggest improvement method of environmental-friendly planning elements of high-rise residential complex by M-IPA. First, as a result, the part of housing subdivision has to keep complex land utilization, environmental-friendly transportation. Second, the part of inside of building shows that ecological housing subdivision, indoor air environment urgent and indoor temperature environment keeps maintaining. Finally, the part of facility/maintenance shows that material and facility, and index of energy management are urgently needed.